Mitsubishi Electric FR-D740-5.5K-CHT FR-D700 Series Variable Frequency Drive

Mitsubishi Electric FR-D740-5.5K-CHT FR-D700 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-D740-5.5K-CHT

  • Country of origin:Hoa Kỳ

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 3300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Engineered for precise motor control in demanding industrial environments, the Mitsubishi Electric FR-D740-5.5K-CHT regulates three-phase AC motors with high thermal and electrical efficiency. This micro-drive delivers a continuous 12.0 A output current and handles a rated capacity of 9.1 kVA, making it highly suitable for machine tools, conveyor belts, and process pumps. Built with an integrated digital dial and a robust cooling structure, it provides outstanding torque control and integrated safety options in a compact space-saving layout.

Features

  • Magnetic Flux Vector Control: Achieves reliable startup torque and smooth acceleration even under varying load conditions.
  • Integrated Digital Dial: Allows for rapid parameter adjustments, setpoint changes, and immediate local control.
  • Modbus RTU Communication: Embedded RS-485 port facilitates seamless communication with PLCs, HMIs, and distributed control architectures.
  • Enhanced Safety Integrity: Built-in safe torque off (STO) safety inputs comply with international machine safety guidelines.
  • Spring Clamp Control Terminals: High-vibration wiring terminals ensure continuous electrical contact without periodic retightening.

Applications

  • Heavy-duty material handling conveyor lines and sorting systems.
  • Industrial fan ventilation systems and centrifugal pump flow regulation.
  • Woodworking machinery, packaging machines, and localized auxiliary automation panels.

Technical Specifications

Manufacturer Mitsubishi Electric
Model Number FR-D740-5.5K-CHT
Series Name FR-D700 Series (FR-D740 micro-drive class)
Voltage Class Three-phase 400V Class
Rated Input Voltage 380 to 480 VAC (+10% / -15%), 50/60 Hz
Applicable Motor Output 5.5 kW (approx. 7.5 HP)
Rated Capacity 9.1 kVA
Rated Output Current 12.0 A
Overload Current Rating 150% of rated current for 60 seconds (inverse-time characteristics)
Cooling System Forced air cooling (with cooling fan)
Protective Design IP20 enclosed type
Net Weight 3.3 kg
Shipping Weight (Calculated) 5.5 kg

Connections and Interfaces

Terminal/Connector Function / Circuit Assignment
R/L1, S/L2, T/L3 Main AC power input connections (three-phase AC power supply)
U, V, W Three-phase AC output connections to the motor
P/+, PR Brake resistor connection terminals (external dynamic braking module)
STF, STR Forward start and Reverse start digital control commands
SD, PC Control circuit common and external 24 VDC power supply terminal
RJ-45 Port RS-485 physical serial port for Modbus RTU interface configuration

Empirical Engineering Insights

Alternative Models & Compatibility

When transitioning from an older FR-S540 or FR-E540 series drive, physical dimensions vary slightly. Check mounting hole patterns as they may require retrofit plates. Additionally, parameters cannot be directly transferred from older software; use the FR Configurator software to align digital input functions, especially when working with remote start commands mapping parameter Pr. 79.

Application Pitfalls & Engineering Notes

Under heavy load or high cycling, inadequate ventilation inside electrical cabinets may lead to premature E.THT (Inverter Overload) trip events. Ensure the cabinet ambient temperature does not exceed 50 degC. When running long motor cable distances (exceeding 30 meters), high-frequency stray capacitance increases. We highly recommend installing an output AC reactor on the U/V/W terminals to mitigate line reflection and protect motor insulation from dv/dt wear.

Commissioning & Wiring Tips

To configure control wiring for sinking (NPN) or sourcing (PNP) logic, locate the physical slide switch hidden under the dynamic panel/display board cover. Ensure this switch is pushed to the correct position matching your master controller outputs before powering on. Shielded control lines must be separated from primary power lines by at least 10 cm, running in orthogonal intersections to avoid inductions and signal noise.

Installation Guidelines

CRITICAL WARNING: Verify that the main AC power input supply is disconnected and locked out. Allow at least 10 minutes after disconnecting power for internal DC bus capacitors to discharge. Confirm that the voltage across terminals P/+ and N/- is below 45 VDC using a certified digital multimeter before touching any terminals.
1

Mount the inverter vertically to a rigid metal sub-panel using four M4 mounting bolts, maintaining a minimum clearances of 50 mm on both top and bottom edges for adequate heat dissipation.

2

Connect the primary ground terminal to the system PE plate, and wire the three-phase power lines directly to terminals R/L1, S/L2, and T/L3. Connect motor phases to U, V, and W.

3

Run low-voltage control lines for emergency stops and digital commands using high-density shielded twisted-pair cables. Ground the shield at the drive terminal block only.

4

Reinstall terminal shields and front safety panel, switch on AC power, and set parameter Pr. 80 (Motor Capacity) and Pr. 9 (Electronic Thermal Overload Relay) based on the motor's nameplate rating.

What is the primary cause of an E.THT trip on this specific Mitsubishi drive?

An E.THT fault indicates inverter overload, commonly triggered by sustained high torque demands, mechanical blockages on the motor shaft, or running at low speeds with insufficient cooling under constant torque.

Which parameter controls the operation mode (external, PU, or network command)?

Parameter 79 (Operation Mode Selection) defines how the drive receives start and speed commands. Setting it to 0 allows dynamic switching, while setting 1 restricts control to the physical PU panel.

Is the cooling fan on the FR-D740-5.5K-CHT field-replaceable?

Yes, the integrated forced cooling fan can be replaced quickly from the top section of the drive unit without dismantling the entire structural housing or disconnecting any power terminal wiring.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...