1 trong số 1

Mitsubishi Electric FX5U-80MT/ESS MELSEC iQ-F Series PLC CPU Module

Mitsubishi Electric FX5U-80MT/ESS MELSEC iQ-F Series PLC CPU Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX5U-80MT/ESS

  • Country of origin:Hoa Kỳ

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 305 mm x 110 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed as a high-performance control engine for the MELSEC iQ-F platform, the Mitsubishi Electric FX5U-80MT/ESS programmable logic controller offers exceptional processing speeds and integrated industrial functionalities. This module features 80 built-in I/O channels (comprising 40 source/sink 24V DC inputs and 40 source-type transistor outputs) designed to coordinate complex automation tasks. The controller incorporates native analog inputs and outputs, a dedicated RS-485 port, and an Ethernet interface to support diverse industrial communication requirements directly from the base unit without requiring additional expansion cards.

Key Features

  • High-Speed System Bus: Facilitates ultra-fast communication with extension modules, minimizing signal propagation delay.
  • Integrated Analog I/O: Built-in 2-channel analog input (0 to 10 V DC) and 1-channel analog output (0 to 10 V DC) for direct sensor and actuator interfacing.
  • Advanced Positioning: Supports built-in 4-axis positioning control with dedicated high-speed counter inputs.
  • Industrial Communications: Native RJ45 Ethernet port and screw-terminal RS-485 connection for seamless integration into factory networks.
  • SD Card Slot: Onboard memory card slot for program logging, firmware updates, and recipe management.

Applications

  • High-speed packaging and sorting machinery.
  • Multi-axis pick-and-place gantry systems.
  • Water treatment control panels with analog flow/pressure monitoring.
  • Conveyor control and material handling distribution systems.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Family MELSEC iQ-F Series (FX5U)
Supply Voltage 100 to 240 V AC (+10% / -15%), 50/60 Hz
Power Consumption 45 W
Total Built-in I/O Points 80 points (40 inputs, 40 outputs)
Input Specifications 24 V DC, 5.3 mA (X0 to X17) / 4.0 mA (X20 and later), Sink or Source configurable
Output Specifications Transistor (Source type), 5 to 30 V DC, 0.5 A per point
Built-in Analog Inputs 2 channels (0 to 10 V DC, input resistance 115 kOhms, 12-bit resolution)
Built-in Analog Output 1 channel (0 to 10 V DC, load resistance 2 kOhms to 1 MOhms, 12-bit resolution)
Built-in Communication Ports 1x RJ45 Ethernet (100Base-TX/10Base-T), 1x RS-485 (terminal block)
Operating Temperature 0 to 55 degC (32 to 131 degF)
Country of Origin Japan
Shipping Weight (Calculated) 1.2 kg (Net), 1.45 kg (Packaged)
Package Dimensions (Calculated) 305 mm x 110 mm x 100 mm

Connections and Interfaces

Terminal Block Section Signal / Pin Assignment Wiring Description
Power Terminals L, N, PE 100 to 240 V AC supply line, neutral, and physical protective earth.
Input Terminals S/S, X0 to X47 Configure S/S terminal for sink (connected to 24V) or source (connected to 0V) operations.
Output Terminals +V0 to +V4, Y0 to Y47 Source transistor outputs. External load connected between Y terminal and 0V line.
Analog Terminals V+, V-, CH1, CH2 Voltage inputs/outputs (0 to 10 V DC) for native processing. Shielded cables required.

Empirical Engineering Insights

Alternative Models & Compatibility

This controller serves as the direct evolutionary upgrade path for legacy FX3U systems. Migration from FX3U to FX5U requires software conversion via GX Works3. Be aware that the I/O terminal block alignment and physical footprint differ from older designs; ensure layout diagrams are updated to accommodate the compact housing of the FX5U model.

Application Pitfalls & Engineering Notes

When utilizing all 40 transistor outputs under continuous maximum switching states in a fully populated cabinet, local thermal limits can be reached. Ensure the enclosure provides adequate passive ventilation or active cooling to maintain ambient temperatures below 55 degC. To prevent inductive kickback from damage, external freewheeling diodes must be mounted parallel to inductive DC loads (solenoids, contactor coils) connected to Y0-Y47.

Commissioning & Wiring Tips

To configure the sink/source digital inputs, the S/S terminal must be explicitly jumpered. Wiring S/S to 24V establishes a sink input loop, whereas wiring S/S to 0V establishes a source loop. Do not leave the S/S terminal floating. For RS-485 communications, enable the terminal resistor (110 Ohm or 330 Ohm) via the built-in switch at physical bus boundaries to prevent data reflection and signal degradation.

Installation Guidelines

CRITICAL WARNING: Disconnect all primary power before mounting, terminating, or modifying wiring on the PLC. Failure to isolate power can result in permanent equipment damage, arc flash, or personal injury. Ensure the auxiliary 24 V DC power supply is monitored and protected by an external fast-acting fuse.
1

Mount the PLC onto a standard 35mm DIN rail inside a protective, IP54-rated or better cabinet to avoid contamination from conductive dust or moisture.

2

Ensure the physical ground terminal (PE) is connected directly to the main cabinet ground bus using a short, low-impedance conductor (minimum 2 mm² copper wire).

3

Isolate high-voltage AC lines from low-voltage DC and communication pathways in separate wire ducts to avoid EMI coupling.

What is the primary difference between the ESS suffix and default FX5U models?

The ESS suffix designates that the module features source-type transistor outputs and uses European-style terminal blocks instead of standard sink-type layouts.

Can I use the integrated analog inputs for 4-20mA current loop signals?

No. The built-in analog inputs on the base unit are designed strictly for 0 to 10 V DC voltage inputs. For 4-20mA signals, an external analog expansion adapter must be added.

Does this CPU module require a separate battery to retain programs during power outages?

No. The unit uses non-volatile Flash ROM memory to store programs and parameters indefinitely without a battery. An optional battery is available only if extensive historical log retention is required.

What software is needed to program this device?

This module is configured and programmed using GX Works3 software within the IQ Works suite.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...