1 trong số 1

Mitsubishi Electric R08ENCPU MELSEC iQ-R Series CPU Module

Mitsubishi Electric R08ENCPU MELSEC iQ-R Series CPU Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: R08ENCPU

  • Country of origin:Hoa Kỳ

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 56 mm x 106 mm x 110 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Operating as the primary sequence control and networking engine within high-demand automation systems, the Mitsubishi Electric R08ENCPU delivers high-speed instruction execution combined with native network integration. Designed for the MELSEC iQ-R Series platform, this CPU module features built-in dual RJ45 ports that support CC-Link IE Controller Network, CC-Link IE Field Network, and standard Ethernet communications directly on the processor card. With an execution speed of 0.98 nanoseconds for basic LD instructions, the module minimizes system cycle times while managing sophisticated control algorithms and high-bandwidth fieldbus data simultaneously.

Key Features

  • Integrated Network Ports: Features embedded CC-Link IE and Ethernet ports, eliminating the need for dedicated network interface modules.
  • High-Speed Sequence Execution: Achieves a basic instruction processing speed of 0.98 ns to ensure rapid output response in critical applications.
  • Substantial Memory Capacity: Outfitted with 80K steps of program memory to handle complex sequential operations, safety logic, and data logging.
  • Multi-CPU Capability: Supports mounting alongside up to three additional MELSEC iQ-R Series CPUs on a single main base unit for distributed task processing.
  • Secure Operations: Includes hardware-level security keys and password authorization to prevent unauthorized program uploads or system tampering.

Typical Industrial Applications

  • Automotive assembly lines with coordinated multi-axis motion control.
  • Semiconductor manufacturing tools demanding cleanroom-compatible high-speed positioning.
  • Water and wastewater processing facilities requiring distributed network architectures.
  • Packaging machinery requiring precise timing and continuous material registration tracking.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number R08ENCPU
Control Series MELSEC iQ-R Series
Program Capacity 80K steps
LD Instruction Execution Speed 0.98 ns
Local I/O Points 4096 points
Internal Current Consumption (5 V DC) 1.49 A
Communication Interfaces CC-Link IE Control, CC-Link IE Field, Ethernet (RJ45 x 2), USB 2.0 (Mini-B)
Operating Temperature Range 0 to 55 degC
Dimensions (W x H x D) 56 mm x 106 mm x 110 mm
Net Weight 0.40 kg

Connections and Interfaces

Interface Port Connector Type Functional Role
P1 (Port 1) RJ45 CC-Link IE Field / Control / Standard Ethernet connection
P2 (Port 2) RJ45 CC-Link IE Field / Control / Standard Ethernet daisy-chain/ring port
USB Connection Mini-B USB Direct local programming, diagnostics, and parameter configuration
SD Memory Slot SD / SDHC Card Slot Data logging, firmware updates, and offline backup storage

Empirical Engineering Insights

Alternative Models & Compatibility

The R08ENCPU represents a double-width module on the iQ-R base unit due to its integrated network hardware. If replacing a standard R08CPU, ensure that you have configured sufficient base unit slot allocation, as the R08ENCPU consumes two physical physical slot locations (though it registers under a single logical slot). When upgrading legacy Q Series systems (e.g., Q06UDVCPU or Q13UDVCPU), program conversion can be performed via GX Works3. However, communication instructions must be refactored to utilize the newer iQ-R system labels and protocol structures.

Application Pitfalls & Engineering Notes

A major parameter to calculate is the internal power consumption. At 1.49 A on the 5 V DC internal bus, this CPU places a significant load on the backplane. When pairing this module with multiple high-current analog modules or additional motion CPUs, verify that the total current draw does not exceed the maximum output of the system power supply module (such as the R61P which provides 5.0 A). If the rating is exceeded, split the configuration across extension base units or upgrade to a higher-capacity power module.

Commissioning & Wiring Tips

To prevent electromagnetic interference from disrupting CC-Link IE communications, double-shielded twisted pair (STP) Category 5e or higher cables must be used. Ensure that the cable shielding is continuously grounded through the RJ45 metallic shell to the main chassis ground of the iQ-R rack. Additionally, if configuring a ring topology on the network, enable the loopback function within the GX Works3 network parameters; otherwise, an accidental break in the ring may cause a communication timeout instead of self-healing.

Installation Guidelines

CRITICAL WARNING: Completely isolate and lockout all primary and control AC/DC power sources feeding the iQ-R backplane and associated field devices before inserting, removing, or wiring the CPU module. Failure to de-energize the assembly may result in critical backplane damage, corruption of the internal CPU boot sector, or severe electrical shock to personnel.
1
Verify that the base unit is securely mounted to a grounded DIN rail or back panel inside an IP54 or higher rated industrial enclosure.
2
Align the upper hook on the back of the R08ENCPU with the slot locating notch on the MELSEC iQ-R base unit.
3
Firmly press the module down onto the connector on the base unit until the module is fully seated and the retention latch clicks locked. Secure the module further using the integrated top retention screw.
4
Connect the industrial STP cables to the RJ45 ports (P1 and P2). Guide the cables through wire ducts to avoid placing physical strain on the RJ45 connectors.

What is the physical slot width occupied by the R08ENCPU on the base unit?

The R08ENCPU is a double-width module due to its integrated dual RJ45 ports. It physically covers two physical slots on the MELSEC iQ-R base unit, but register-wise it occupies only one logical slot.

Does this CPU module require a separate network card for CC-Link IE Field?

No. The module has a built-in Ethernet controller that natively supports CC-Link IE Field Network, CC-Link IE Control Network, and standard TCP/IP Ethernet communications directly from ports P1 and P2.

What software is used to program and configure the R08ENCPU?

The module must be programmed, configured, and diagnosed using GX Works3 software, which is part of the iQ Works engineering suite.

What is the maximum current consumption of this unit, and why is it important?

It consumes 1.49 A on the internal 5 V DC bus. It is critical to ensure that the sum of the current consumption of all modules on the backplane does not exceed the current rating of your system power supply module.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...