1 trong số 1

Omron CP1L-M30DT-D CP1L Series Programmable Logic Controller CPU Module

Omron CP1L-M30DT-D CP1L Series Programmable Logic Controller CPU Module

Only 7 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: CP1L-M30DT-D

  • Country of origin:Nhật Bản

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Executing automation routines via a stored program architecture, the Omron CP1L-M30DT-D micro-PLC delivers high-performance processing coupled with integrated Ethernet communications. Designed to fit within compact panel layouts, this CP1L series CPU module utilizes a cyclic scan processing method with immediate I/O refreshing, enabling high-speed response times for complex machinery. The unit supports versatile programming options, allowing engineers to write logic using standardized ladder diagrams and Structured Text (ST) inside function blocks, ensuring seamless integration into modern industrial control architectures.

Features

  • Flexible Programming Environment: Supports up to 128 function block definitions and 256 instances using ladder logic and Structured Text (ST).
  • High-Speed Instruction Execution: Executes basic logical instructions in 0.55 us minimum and special instructions in 4.1 us minimum.
  • Robust Task Management: Manages up to 288 concurrent tasks, structured as 32 cyclic tasks and 256 interrupt tasks.
  • Integrated Analog Channel: Features one onboard analog input (0 to 10 VDC range) with a 1/256 resolution for basic voltage monitoring without auxiliary cards.
  • Expandable Hardware Design: Allows physical expansion of system capacity by connecting up to 3 CP-series expansion or I/O units.

Applications

  • Packaging and labeling machinery requiring high-speed execution.
  • Material handling systems, conveyor control, and sorting systems.
  • Pump control panels and water distribution systems requiring embedded Ethernet telemetry.
  • Custom machine-tool automation utilizing interrupt inputs and high-speed counter modes.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number CP1L-M30DT-D
Control Method Stored program method
I/O Control Method Cyclic scan with immediate refreshing
Program Capacity 10K steps
Basic Instruction Execution Time 0.55 us (microseconds) minimum
Special Instruction Execution Time 4.1 us (microseconds) minimum
Common Processing Time 0.4 ms
Input Area 1,600 bits (100 words), CIO 0 to CIO 99
Output Area 1,600 bits (100 words), CIO 100 to CIO 199
Work Bits 8,192 bits (512 words), W0 to W511
Holding Area 8,192 bits (512 words), H0 to H511
Timers 4,096 timer numbers (T0 to T4095)
Interrupt Inputs 6 inputs (Response time: 0.3 ms)
Interrupt Counter Mode 6 inputs (Response frequency: 5 kHz max), 16-bit up/down
Analog Controls 1 adjustment dial (Setting range: 0 to 255)
Onboard Analog Input 1 input (0 to 10 V, 1/256 resolution, non-isolated)
Shipping Weight (Calculated) 3.00 kg (with protective distribution packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The CP1L-M30DT-D requires a nominal 24 VDC power source, as indicated by the trailing "-D" suffix. Care must be taken not to substitute this model directly with the "-A" variant (e.g., CP1L-M30DT-A), which operates on 100-240 VAC mains power. Converting programs from older CP1E systems to CP1L is fully supported within CX-Programmer, though physical terminal configuration differences must be verified prior to downloading the updated task structures.

Application Pitfalls & Engineering Notes

The integrated 0-10 VDC analog input is non-isolated. Deploying this input in environments with high electromagnetic interference (EMI) or severe ground potential differences can corrupt analog measurements. For reliable performance, keep signal cables as short as possible, route them away from variable frequency drive (VFD) output cables, and use high-quality shielded twisted-pair wiring. If isolation is critical, use an external signal isolator before routing to the controller.

Commissioning & Wiring Tips

When configuring the embedded Ethernet interface, ensure the local subnet of your programming workstation matches the PLC default IP allocation. High-speed interrupt inputs (configured for 5 kHz counter operations) require low-capacitance cabling to avoid pulse signal dampening. Ensure the functional ground (FG) terminal is securely tied to a low-impedance earth ground to maximize internal noise filtering performance.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources before attempting mounting, removal, or connection of the CPU module. Confirm that the input voltage matches the specified 24 VDC threshold. Failure to disconnect active field wiring or applying incorrect input voltages can result in permanent hardware failure, circuit damage, or electric shock.

1 Mount the CPU module securely onto standard 35 mm DIN rail or directly to the panel backplate using the mounting screws, ensuring adequate ventilation spacing of at least 50 mm above and below the unit.
2 Connect the external 24 VDC power supply to the dedicated power terminals. Double-check polarity configuration to prevent internal fuse degradation.
3 Ground the PLC functional ground (FG) terminal directly to the panel main earth ground bar using a low-impedance conductor of at least 2.0 mm square.
4 Terminate industrial Ethernet and high-speed I/O field cables, keeping signal lines separate from high-voltage AC lines to minimize signal interference.

What is the power supply requirement for this controller?

The 'D' suffix in the model code indicates a 24 VDC power supply requirement. Do not connect AC mains power directly to this unit.

What is the resolution of the built-in analog input?

The onboard analog input has a resolution of 1/256 with an input range of 0 to 10 VDC. Note that this integrated analog channel is non-isolated.

How many expansion units can be connected?

A maximum of 3 CP-series expansion units or expansion I/O units can be directly connected to expand system capabilities.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Nhật Bản

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...