1 trong số 1

Omron F3SJ-E0465N25 F3SJ Series Safety Light Curtain

Omron F3SJ-E0465N25 F3SJ Series Safety Light Curtain

Only 4 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: F3SJ-E0465N25

  • Country of origin:Nhật Bản

  • Product Type: Safety Light Curtains

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Engineered to deliver simplified, Type 4 machine guarding in automated environments, the Omron F3SJ-E0465N25 provides reliable optoelectronic presence sensing. This Easy-type (F3SJ-E) safety light curtain features a 465 mm protective height and a 25 mm detection capability specifically optimized for hand protection. It operates on an NPN output configuration, making it compatible with sinking logic safety controllers and relays. By focusing on essential on-off safety functions, it minimizes wiring complexity and setup time while maintaining compliant industrial safeguarding performance.

Key Features

  • Type 4 Safety Rating: Compliant with international safety standards including EN ISO 13849-1 PL e and IEC 61508 SIL3.
  • Optimized Resolution: 25 mm beam gap designed specifically for reliable hand and arm detection.
  • NPN Output Architecture: Twin NPN solid-state outputs (OSSDs) for seamless integration with sinking control systems.
  • Simplified Wiring: Reduced wiring design using standard M12 connections, omitting complex auxiliary functions to prevent field configuration errors.
  • Robust Optical Range: Operating scanning range of 0.2 m to 7.0 m, covering a wide array of machine entry points.

Applications

  • Robotic Workcells: Guarding primary access areas and perimeter entry points of robotic arms.
  • Packaging and Conveying: Presence detection and worker protection around automated palletizers and cartooning systems.
  • Assembly Lines: Point-of-operation safeguarding on semi-automated workstations and pneumatic presses.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number F3SJ-E0465N25
Series Type F3SJ-E (Easy Type)
Safety Category Type 4, PL e, SIL 3
Protective Height 465 mm
Detection Capability 25 mm diameter (Hand)
Number of Beams 22
Beam Gap 20 mm
Operating Range 0.2 m to 7.0 m
Output Type NPN (x2 OSSD outputs)
Supply Voltage (Vs) 24 VDC plus/minus 20% (SELV/PELV)
Light Source Infrared LED (870 nm)
Current Consumption (Emitter) 41 mA max.
Current Consumption (Receiver) 40 mA max.
Enclosure Rating IP65 (IEC 60529)
Net Weight 1.8 kg
Shipping Weight (Calculated) 3.0 kg

Connections and Interfaces

M12 Connector Pin Emitter Function Assignment Receiver Function Assignment
Pin 1 (Brown) +24 VDC Power Input +24 VDC Power Input
Pin 2 (White) Not Used (NC) OSSD 2 Output
Pin 3 (Blue) 0 VDC Power Input 0 VDC Power Input
Pin 4 (Black) Test Input OSSD 1 Output

Empirical Engineering Insights

Alternative Models & Compatibility

The F3SJ-E "Easy" series is designed for straightforward on-off detection. Unlike the Advanced (F3SJ-A) and Basic (F3SJ-B) series, the F3SJ-E series does not support series connection (cascading) for multi-sided safety fields. Emitters and receivers must be replaced in identical matched pairs; pairing an F3SJ-E emitter with an F3SJ-B receiver will result in a synchronization fault. Always verify the prefix/suffix matches during drop-in replacements to prevent field pairing errors.

Application Pitfalls & Engineering Notes

Because this model features NPN outputs (N25 suffix), it cannot be wired directly to PNP-only safety monitoring modules. Integrating this light curtain into a PNP-based system requires an external NPN-to-PNP converter or a dedicated safety relay compatible with dual sinking inputs. Additionally, ensure the structural mounting is completely rigid; thermal expansion or frame vibrations can easily disrupt optical alignment across the 7.0-meter operating threshold, triggering intermittent OSSD dropouts.

Commissioning & Wiring Tips

To maintain complete electromagnetic immunity, execute correct shielding procedures. The cable shield must be grounded at the control panel chassis. Avoid routing the emitter/receiver cables in parallel with high-power motor lines or variable frequency drive (VFD) output cables. When configuring the Test Input on the emitter, wire it to an external control device to periodically verify system shut-off function as mandated by local safety standards.

Installation Guidelines

CRITICAL WARNING:

Ensure all primary electrical supply lines are locked and tagged out prior to physical installation. De-energize the entire cabinet and verify zero electrical potential. Failure to do so can result in permanent device damage, immediate optical array failure, or severe injury from unexpected machinery start-up.

1
Mechanical Alignment: Securely mount the emitter and receiver directly parallel to each other at the exact height required, ensuring both units sit completely plumb on their vertical axes.
2
Cable Connection: Connect the 4-pin M12 cables to both the emitter and receiver. Route cables using dedicated low-voltage conduit to avoid electromagnetic noise.
3
Optical Verification: Apply 24 VDC power and check the diagnostic LEDs on the receiver. Rotate the housings slightly to find the optimal optical sweet spot where the alignment indicators glow solid green.

Can the F3SJ-E0465N25 be cascaded for multi-segment guarding?

No, the F3SJ-E Easy Series does not support cascading. For multi-segment or serial connections, select the F3SJ-B (Basic) or F3SJ-A (Advanced) series.

What does the 'N25' suffix represent in the model code?

The 'N' denotes NPN solid-state safety outputs (sinking logic), and '25' indicates a 25 mm detection capability designed specifically for industrial hand protection.

How do I troubleshoot intermittent optical alignment dropouts?

Check structural rigidity to eliminate machine frame vibrations. Additionally, ensure there are no highly reflective metal surfaces within the optical path angle limit of the emitter and receiver.

Can this unit be wired to a PNP safety controller?

It cannot be wired directly to PNP inputs because of its NPN sinking output stage. An intermediate NPN-to-PNP safety interface relay module must be used.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Nhật Bản

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...