Omron NS5-SQ00B-V2 NS Series Interactive Display Panel

Omron NS5-SQ00B-V2 NS Series Interactive Display Panel

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NS5-SQ00B-V2

  • Country of origin:Nhật Bản

  • Product Type: HMI Operator Panels

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed for industrial machine-level visualization, the Omron NS5-SQ00B-V2 serves as a high-reliability interactive human-machine interface (HMI) within modern automation architectures. This panel bridges the communication gap between operators and PLCs, providing responsive touch control and reliable diagnostic displays. Configured with an energy-efficient display system, it operates seamlessly under demanding factory conditions while maintaining a low thermal signature inside electrical control panels.

Key Features

  • Stable Input Power: Optimised for 24 VDC standard industrial distribution networks.
  • Low Power Footprint: Consumes a maximum of 15 W, reducing heat dissipation within sealed enclosures.
  • Long-Term Data Integrity: Integrated memory backup battery features a nominal 5-year service life.
  • Environmental Protection: Built to withstand standard operational wear in environments clear of corrosive gases.

Applications

  • Automated assembly and packaging machinery interfaces.
  • Local control stations in water treatment and material handling facilities.
  • Process visualization terminals in food processing and manufacturing environments.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number NS5-SQ00B-V2
Device Type Interactive Display Panel (HMI)
Rated Voltage 24 VDC
Power Consumption 15 W maximum
Operating Environment No corrosive gases
Memory Backup Battery Life 5 years
Net Weight 1.0 kg
Shipping Weight 8.0 kg (including protective packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The -V2 designation marks a hardware revision that expands screen transfer capabilities and improves direct communication driver support for newer CJ2 and NJ/NX controllers compared to legacy V1 or non-suffix NS5 hardware. Screen files developed in CX-Designer can be easily converted and downloaded, but ensure the target system's system program (firmware) is updated to the matching runtime version of the project.

Application Pitfalls & Engineering Notes

Sustained operation in environments exceeding 40 degC significantly shortens the lifespan of both the screen backlight and the internal backup battery. If mounting within airtight enclosures alongside heat-generating components like active variable speed drives, install supplementary panel cooling or fan systems to prevent localized thermal degradation.

Commissioning & Wiring Tips

When wiring serial communications, use high-quality, individually shielded twisted-pair cables for the RS-232C connections to prevent noise coupling. Avoid routing communication lines parallel to high-current motor leads or power supply distribution cables within the wire ducts to ensure reliable high-speed data transmission.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL SHOCK HAZARD

Isolate and lock out all incoming 24 VDC power sources before mounting, wiring, or replacing the backup battery on this unit. Verify the complete absence of voltage with a calibrated instrument before beginning manual tasks to prevent personal injury or hardware destruction.

1

Prepare a precise panel cutout matching the specified mounting dimensions for the 5.7-inch NS5 chassis.

2

Insert the HMI unit into the cutout, ensuring the integrated waterproof rubber sealing gasket is seated uniformly flat against the front surface of the panel.

3

Secure the panel in position using the provided mounting brackets, tightening them evenly to the specified torque to maintain environmental sealing ratings without warping the front bezel.

4

Connect the dedicated functional ground terminal on the rear of the device to a verified low-impedance facility grounding bar using a minimum 2.0 sq mm copper wire.

What is the expected backup battery lifespan for this HMI and how is it replaced?

The integrated memory backup battery has a typical service life of 5 years when operated under standard conditions. It can be replaced from the rear compartment of the panel while the system is powered down, though a quick swap is recommended to prevent the loss of internal system settings.

Does the NS5-SQ00B-V2 support direct EtherNet/IP communications?

This model relies on serial RS-232C interfaces for its primary communication channels. To utilize Ethernet-based networking protocols, a compatible expansion network board or an external adapter must be integrated.

What software is required to program and transfer screens to this display panel?

The panel is programmed using CX-Designer, which is a core utility included within Omron's CX-One automation software suite. Screens can be transferred via a standard USB connection or the serial ports.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Nhật Bản

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...