1 trong số 3

Siemens 6ES7138-4FA03-0AB0 SIMATIC ET 200S Fail-Safe Digital Input Module

Siemens 6ES7138-4FA03-0AB0 SIMATIC ET 200S Fail-Safe Digital Input Module

Only 5 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7138-4FA03-0AB0

  • Country of origin:Đức

  • Product Type: Fail-Safe PLC I/O Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 10.5 x 12.5 x 4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

This is a Siemens 6ES7138-4FA03-0AB0 fail-safe digital input module for the SIMATIC ET 200S distributed I/O system. It is engineered to acquire safety-related signals from field devices, providing 4 or 8 configurable channels of 24V DC inputs that communicate via the PROFIsafe protocol. The module is certified to meet high safety standards, including SIL 3 (IEC 62061) and PL e (ISO 13849), making it suitable for critical safety functions. Its compact 30mm form factor optimizes cabinet space while offering flexible integration into both PROFIBUS DP and PROFINET networks when used with compatible interface modules.

Features

  • Configurable for 4 or 8 fail-safe digital input channels.
  • Supports the PROFIsafe protocol for secure data transmission.
  • Certified for Category 4 (EN 954-1), SIL 3 (IEC 62061), and PL e (ISO 13849).
  • Compatible with both PROFIBUS DP and PROFINET networks.
  • Features optical isolation for signal integrity.
  • Includes comprehensive diagnostic capabilities.
  • Compact 30mm width for high-density installations.

Applications

  • Emergency stop circuits
  • Safety gate and light curtain monitoring
  • Automotive manufacturing lines
  • Packaging and material handling machinery
  • Distributed safety systems requiring high integrity levels

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6ES7138-4FA03-0AB0
Product Series SIMATIC ET 200S
Module Type Fail-Safe Digital Input Module
Number of Inputs 4 or 8, configurable
Input Voltage 24V DC
Safety Communication PROFIsafe
Supported Networks PROFIBUS DP, PROFINET
Safety Integrity Level SIL 3 according to IEC 62061
Performance Level PL e according to ISO 13849-1
Safety Category Category 4 according to EN 954-1
Module Width 30 mm
Shipping Weight 0.24 kg
Package Dimensions (Calculated) 10.5 x 12.5 x 4 cm
Country of Origin Germany

Installation Guidelines

CRITICAL WARNING: Installation, commissioning, and maintenance of this safety-rated module must be performed by qualified personnel with expertise in functional safety standards (e.g., IEC 61508, ISO 13849). Failure to correctly install, configure, and validate the safety function can result in serious injury or death.
  1. 1
    De-energize System: Before installation, disconnect and lock out all power sources to the control panel and the ET 200S station according to established Lockout/Tagout (LOTO) procedures. Verify that all circuits are de-energized.
  2. 2
    Mount Terminal Module: Securely mount the appropriate ET 200S terminal module (e.g., TM-E30) onto the DIN rail. Ensure a solid mechanical and electrical connection to the rail for proper grounding.
  3. 3
    Install Electronic Module: Align the 6ES7138-4FA03-0AB0 electronic module with the terminal module and firmly press it into place until it audibly clicks, ensuring it is fully seated and engaged with the backplane bus connectors.
  4. 4
    Connect Sensor Wiring: Terminate the wiring from safety sensors (e.g., E-stops, gate switches) to the designated terminals on the terminal module. Use shielded, twisted-pair cabling for all safety circuits and ensure shields are properly grounded at one end to minimize noise interference.
  5. 5
    Commission and Validate: After restoring power, use the engineering software to configure the module's PROFIsafe address and parameters. Perform a comprehensive functional test of every safety input to validate that the system behaves as designed and meets the required safety performance level.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...