1 trong số 1

X20SO4120 B&R X20 Series 4-Channel High-Current Safe Output Module

X20SO4120 B&R X20 Series 4-Channel High-Current Safe Output Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20SO4120

  • Country of origin:Hoa Kỳ

  • Product Type: X20 Safe Output Module

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The X20SO4120 (X20SO4120) is a high-performance, intelligent safety output module designed for the B&R X20 system. Engineered to meet the most stringent safety requirements (up to SIL 3 / PLe), this module features 4 safe digital Type A outputs, each capable of delivering up to 2 A of current. This high-current capacity makes the X20SO4120 ideal for directly driving larger safety actuators, heavy-duty contactors, and hydraulic valves without the need for interposing relays. With integrated OSSD (Output Signal Switching Device) functionality and a diagnostic pulse width of less than 500 microseconds, the module ensures continuous monitoring for short circuits and cross-faults, maintaining maximum safety integrity in high-speed automated environments such as metal forming, robotic cells, and heavy material handling.

Technical Configuration

The hardware of the X20SO4120 is built for transparency and resilience. It features individual current monitoring for each channel, allowing the Safety CPU to detect "stuck-at" faults or load anomalies in real-time. The module identifies itself in the system via the B&R ID code 0x2007 and provides comprehensive visual diagnostics through LEDs indicating I/O function per channel, operating state, and general module status. Power management is highly efficient, with a bus consumption of just 0.25 W, while the internal I/O circuitry draws 1.3 W. By utilizing the openSAFETY protocol, the X20SO4120 provides a seamless, deterministic safety loop that minimizes the time between a fault detection and the transition to a Safe State.

Technical Specifications

Feature Specification Details
Model X20SO4120
Brand B&R Industrial Automation
B&R ID Code 0x2007
Module Type Safe Digital Output (Type A)
Number of Outputs 4
Nominal Voltage 24 VDC
Output Current 2.0 A per channel
OSSD Pulse Width Less than 500 microseconds
Current Monitoring Integrated (Per channel)
Power Consumption (Bus) 0.25 W
Power Consumption (I/O) 1.3 W
Safety Certification SIL 3, PLe
Protection Rating IP20
Shipping Weight 1.5 kg

Technical FAQs

How does the 2 A rating of the X20SO4120 compare to the X20SO4110?

The X20SO4120 provides a significantly higher output capacity (2 A per channel) compared to the X20SO4110 (0.5 A). This allows the 4120 variant to drive high-power inductive loads like large DC brakes or pneumatic manifolds directly, which would otherwise exceed the current limits of standard safe output modules.

What diagnostics are available via the status indicators?

The module features LEDs for "Operating State" and "Module Status," which indicate if the module is in safe-run mode, pre-operational mode, or a fail-safe state. Additionally, individual "I/O function" LEDs light up when an output is energized, and flash patterns can indicate specific faults like short circuits or overcurrent.

Is the OSSD pulse width adjustable?

The <500 microsecond pulse width is a fixed hardware characteristic designed to ensure that the "off-test" is too fast for the mechanical contacts of a relay or valve to respond, thus preventing chattering while maintaining a high diagnostic coverage.


Engineering & Installation Guide

  • Total Current Calculations: With a 2 A capacity per channel, a fully loaded module can draw up to 8 A. It is critical to ensure that the X20 power supply module (e.g., X20PS) feeding this segment is rated for the cumulative peak current and that the supply wiring is of sufficient gauge to prevent voltage drops during simultaneous switching.

  • Inductive Load Protection: When controlling large inductive loads, the back-EMF can be substantial. Although the X20SO4120 has internal protection, adding an external recovery diode or varistor at the load side is recommended for 2 A applications to reduce electromagnetic noise and thermal stress on the module’s transistors.

  • Safe Wiring separation: To maintain the SIL 3 rating, keep the safe output wiring physically separated from high-voltage AC cables. Use shielded cables for the 24 VDC lines if they run parallel to motor cables for long distances to prevent induced voltages from interfering with the OSSD pulse detection logic.

 

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Vàng
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...