1 от 3

ABB 07 DI 92 GJR5 2524 00 R0101 Digital input module

ABB 07 DI 92 GJR5 2524 00 R0101 Digital input module

Only 6 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: 07DI92 GJR5252400R0101

  • Country of origin:Германия

  • Product Type: Digital input module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 120 mm W x 140 mm H x 85 mm D

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The ABB 07 DI 92 GJR5 2524 00 R0101, also recognized under the engineering database entry 07DI92 GJR5252400R0101, is a high-density decentralized digital input module designed for the Advant Controller 31 (AC31) core automation platform. Functioning as a remote bus node on the standardized CS31 system bus, this module facilitates localized binary telemetry collation from fields straight to the central processing architecture. This unit incorporates 32 digital input channels configured for 24 V DC monitoring loops. To maximize signal reliability against electromagnetic disruptions and ground tracing errors, the device relies on comprehensive galvanic optocoupler isolation between the binary sensor interface and the internal data backbone. Utilizing an EIA RS-485 link interface, it delivers stable state mapping, transient suppression, and high continuous uptime across chemical, manufacturing, and distribution installations.

Features

  • Integrates 32 binary inputs rated at a nominal processing voltage threshold of 24 V DC.
  • Establishes secure multi-drop remote network routing using the verified EIA RS-485 CS31 system bus protocol.
  • Maintains safe electrical boundaries via internal optocoupler assemblies isolating processing CMOS lines from field-side transients.
  • Provides comprehensive diagnostics using a front-panel LED matrix dedicated to individual channel values and bus line tracking statuses.
  • Suppresses erratic mechanical contact bounce and line interference through internal hardware input delay filter configurations.
  • Simplifies configuration via a manual binary DIL switch array accessible beneath a lateral sliding protective door interface.

Applications

  • Distributed multi-point limit switch monitoring and digital telemetry aggregation within Advant Controller 31 automation networks.
  • High-density sensor signal marshaling inside centralized low-voltage switchgear enclosures and remote control desks.
  • Continuous packaging lines and material handling infrastructure demanding decentralized input mapping with minimal latency.
  • Remote auxiliary contact tracking for circuit breakers, isolation valves, and emergency shutdown safety interlocks.

Ordering Information

Model Order Number
07 DI 92 (07DI92) Digital Input Module GJR5 2524 00 R0101 (GJR5252400R0101)

Technical Specifications

Parameter Category Technical Specifications
Manufacturer ABB
Model Designation 07 DI 92 / 07DI92
Order Number GJR5 2524 00 R0101 / GJR5252400R0101
Product Function Digital Input Module
System Compatibility Advant Controller 31 (AC31 / 90 Series)
Network Connection Type CS31 System Bus (EIA RS-485 Standard)
Total Input Channels 32 Channels
Nominal Supply Voltage 24 V DC
Operational Temperature Envelope 0 to 55 Celsius
Storage Temperature Bound -25 to 75 Celsius
Galvanic Isolation Integrated via optocouplers between data backbone and binary process line
Local Status Monitoring Direct LED panel array mapping channel values and communications diagnostics
Mechanical Dimensions 120 mm Width x 140 mm Height x 85 mm Depth
Net Module Weight 450 g
Country of Origin Germany
Shipping Weight (Calculated) 0.55 kg
Package Dimensions (Calculated) 135 mm x 155 mm x 100 mm

Installation Guidelines

CRITICAL WARNING: COMPLETE SYSTEM POWER DE-ENERGIZATION REQUIRED

Isolate and lock out all 24 V DC instrumentation loops, auxiliary power supplies, and field signal power links before starting any module configuration, wire termination, or block changeout procedures. Operating or connecting data line plugs during live electrical status can initiate field line transients, generate false PLC execution faults, and cause severe, unrecoverable damage to localized internal CMOS processing chips.

1
Hook the upper attachment flange of the module over the top edge of a thoroughly grounded standard 35 mm top-hat DIN rail section, applying stable down-and-back physical force until the integrated structural spring clip seats firmly. Alternatively, use four M4 screws to fasten the rear housing plate flat onto a rigid layout subpanel.
2
Retract the transparent protective dust plate cover located on the right vertical surface of the housing structure. Configure the physical binary switches to match the desired CS31 bus remote station destination index value before initializing loop power configurations.
3
Lead the discrete multi-point 24 V DC field wires to the respective terminal pin configurations. Use high-integrity copper conductors, utilizing a maximum core sizing profile of 2.5 mm2 for power distribution runs and 1.5 mm2 for individual input processing lines.
4
Terminate the incoming and outgoing RS-485 serial fieldbus wires of the CS31 framework. Connect the structural cable foil shield material securely to a common earthing bar directly at the control cabinet layout threshold to ensure thorough electromagnetic shielding compliance.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB 07 DI 92 GJR5 2524 00 R0101 Digital input module

Are the 32 discrete digital inputs on this module electrically isolated from one another?

No, the 32 input channels utilize a shared reference potential internally. However, high-voltage galvanic isolation via integrated optocouplers is maintained between the combined field input channel block and the underlying internal CS31 system bus network components.

How is the target field network address set on this digital input block?

The unique network address is assigned manually via a dedicated binary DIL switch block found behind the slide-open clear protective plastic shield on the right flank of the unit. This step must be performed prior to system startup.

What is the primary function of the integrated hardware filter circuit on the inputs?

The module utilizes an internal hardware signal delay function on its inputs. This delays incoming data to suppress transient induction noise and eliminate mechanical sensor contact bounce before passing the logical state to the master processor.

Is an online application logic download necessary when completing a hot swap or cold module replacement?

No, because the module does not contain independent user application programs or custom project parameter files. When changing a device out, ensure the manual binary DIL address toggles match the replaced device exactly before reconnecting power.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял
Country of origin
Германия
Power source
Постоянен ток

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...