1 от 3

ABB IPMON01 Bailey INFI 90 Power Montior Module

ABB IPMON01 Bailey INFI 90 Power Montior Module

Only 2 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: IPMON01

  • Country of origin:Съединени щати

  • Product Type: Power Montior Module

  • Barcode: 8538908180

  • Payment: T/T, Western Union

  • Weight: 1542g

  • Dimensions: 275 mm x 40 mm x 195 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

The ABB IPMON01 is a Power Monitor Module designed for the Bailey INFI 90 OPEN Modular Power System II. This module serves as a central diagnostics and monitoring interface within the system, providing real-time data on system bus voltages, input power status, and localized environmental or hardware parameters. The ABB IPMON01 features three red/green status LEDs, eight red alarm LEDs, and an integrated interface for direct diagnostics. It assesses the health of input power lines, system and I/O bus voltages, and external conditions like cabinet temperature and cooling fan operation to protect critical infrastructure.

Features

  • Integrates three dual-color red/green status LEDs (Self-check, Line 1, Line 2) for immediate operational status verification.
  • Features eight dedicated red alarm LEDs to isolate faults such as power supply failure, overtemperature conditions, fan failure, and PFI status.
  • Configurable LED operation controlled via internal dipswitch and jumper settings to monitor multiple lines, buses, and distinct hardware signals.
  • Includes six physical faceplate test points enabling direct bus voltage measurements via voltmeter probes.
  • Equipped with a faceplate PFI reset pushbutton to clear latched power fail interrupt signals after fault conditions resolve.

Applications

  • Bailey INFI 90 OPEN Modular Power System II diagnostic monitoring.
  • Real-time voltage loop and operational fault tracking in industrial power architectures.
  • Overtemperature and cooling fan failure tracking within electronic enclosures.

Technical Specifications

Parameter Specification
Manufacturer ABB / Bailey
Product ID IPMON01
Product Series INFI 90 OPEN Modular Power System II
Module Type Power Monitor Module
Medium Description MODULE ASSY
Status LEDs Self-check (Red/Green), Line 1 (Red/Green), Line 2 (Red/Green)
Alarm LEDs Power supply, Cabinet temp, Fan left, Fan right, External, System power, I/O power, PFI (All Red)
Faceplate Test Points +5 Volts, +15 Volts, -15 Volts, Module Com, +25.5 Volts, I/O Common
Pushbutton Interface PFI Reset Pushbutton
Country of Origin United States (US)
Customs Tariff Number 8538908180
Gross Weight 1.542 kg

Ordering Information

Description Value
Part Type New
Minimum Order Quantity 1 EA
Order Multiple 1 EA
Selling Unit of Measure each

Installation Guidelines

  • Document and verify all dipswitch and jumper configurations prior to module insertion to ensure correct mapping of lines, buses, and alarm signals.
  • Ensure proper structural grounding and isolate power sources before manipulating hardware components inside the drive or system cabinet.
  • Align the module along the chassis guide rails to protect backplane pins and component infrastructure from mechanical damage during seating.
  • Keep an updated copy of the dipswitch and jumper configuration matrix inside or near the cabinet enclosure as a reference guide for maintenance personnel.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB IPMON01 Bailey INFI 90 Power Montior Module

What is the function of the test points on the faceplate of the module?

The six faceplate test points allow technical personnel to take precise bus voltage measurements using physical voltmeter probes.

How do the Self-check and Line 1 LEDs indicate status on the device?

Both are dual-color status LEDs. They remain green during normal operation. The Self-check LED turns red upon detecting an internal hardware failure, and the Line 1 LED turns red if input power falls outside the specified operating range.

What is the purpose of the PFI reset pushbutton on the device?

The PFI reset pushbutton is used to manually clear a latched PFI alarm signal once the underlying power fail interrupt condition has returned to normal parameters.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Точки
Country of origin
Съединени щати
Power source
Постоянен ток

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...