1 от 3

Allen-Bradley 1756-OB16IS ControlLogix Scheduled Isolated Output Module

Allen-Bradley 1756-OB16IS ControlLogix Scheduled Isolated Output Module

Only 6 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-OB16IS

  • Country of origin:Съединени щати

  • Product Type: Digital Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 3.5cm x 14.2cm x 14.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

The 1756-OB16IS is a digital output execution component built for the ControlLogix system configuration. It functions within a nominal 12/24V DC voltage envelope, featuring 16 channels that are isolated individual points designed to secure downstream circuitry against cross-signal disturbance and transient spikes. This module integrates 8 scheduled output points designed to enable precise synchronization matching coordinated machine sequences with reference to the Coordinated System Time. It installs inside standard control slots, interfacing with industrial field loads via specified removable termination assemblies to provide deterministic actuation and steady processing states under multiple manufacturing control configurations.

Features

  • Incorporates 16 isolated output channels providing basic insulation between output points and backplane circuits.
  • Features 8 scheduled outputs allowing time-stamped task performance linked directly with coordinated control architecture.
  • Provides sinking or sourcing load matching with an execution range spanning 10V DC to 30V DC field operations.
  • Delivers continuous visual verification of independent output channel execution states and module hardware health.
  • Supports electronic, software-configurable keying options to enforce accurate hardware module matching upon slot replacement.

Applications

  • High-speed sorting and discrete tracking machinery requiring timed sequence control.
  • Solenoid valve switching loops and isolated pilot relay driving circuits.
  • Multi-zone industrial heating elements requiring synchronized control pulses.

Technical Specifications

Parameter Specification
Outputs 16 individually isolated, 8 scheduled
Pilot Duty 2 A (DC-13SQ)
Voltage Category 12/24V DC sink/source
Operating Voltage Range 10...30V DC
Output Delay Time (Off to On) 1 ms max
Output Delay Time (On to Off) 2 ms max
Current Draw @ 5.1V 350 mA
Current Draw @ 24V 2.5 mA
Total Backplane Power 1.8 W
Power Dissipation, Max 3.6 W @ 60 degC (140 degF)
Thermal Dissipation 12.28 BTU/hr
Off-State Leakage Current Per Point, Max 0.5 mA per point
On-State Voltage Drop, Max 1.2V DC @ 2 A
Current Per Point, Max 2 A @ 30 degC (86 degF), 1 A @ 60 degC (140 degF) (linear derating)
Current Per Module, Max 8 A @ 30 degC (86 degF), 4 A @ 60 degC (140 degF) (linear derating)
Surge Current Per Point 4 A for 10 ms per point, repeatable every 2 s
Load Current, Min 1 mA per point
Scheduled Outputs Synchronization Within 16.7 s max, reference to the Coordinated System Time
States in Fault Mode Per Point Hold last state, On or Off (Off is default)
States in Program Mode Per Point Hold last state, On or Off (Off is default)
Isolation Voltage 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
Module Keying Electronic, software configurable
Removable Terminal Block 1756-TBCH, 1756-TBS6H
RTB Keying User-defined mechanical
Slot Width 1
Wire Category 1
Wire Type Copper
Enclosure Type None (open-style)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 2 g @ 10...500 Hz
Shock, Operating 30 g
Shock, Nonoperating 50 g
Emissions IEC 61000-6-4

Installation Guidelines

  • Ensure conductor routing follows specified guidelines for Wire Category 1 paths to reduce crosstalk with high-voltage power components.
  • Use only approved ControlLogix Removable Terminal Blocks, specifically models 1756-TBCH or 1756-TBS6H, to wire external field outputs.
  • Set the software-based electronic keying attributes accurately within the project configuration to prevent mismatched module replacement errors.
  • Apply appropriate current derating factors when operating ambient conditions rise, limiting per-point current to 1 A when reaching 60 degC.
  • Mount the open-style chassis assembly inside an enclosure that offers appropriate protective barrier sealing against environmental particulates.

Compliance and Certifications

  • cULus Listed Industrial Control Equipment (UL File E65584)
  • cULus Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)
  • CE (European Union 2014/30/EU EMC Directive, EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2; 2014/35/EU LVD Directive, EN 61131-2)
  • RCM (Australian Radiocommunications Act, EN 61000-6-4)
  • ATEX (European Union 2014/34/EU ATEX Directive, EN IEC 60079-0, EN IEC 60079-7, II 3 G Ex ec IIC T4 Gc, UL22ATEX2820X)
  • IECEx (IEC 60079-0, IEC 60079-7, II 3 G Ex ec IIC T4 Gc, IECEx UL 22.0065X)
  • UKex (UKEX Regulation 2016 No. 1107, Equipment protection by increased safety "e", UL22UKEX2602X, Zone 2 classification)
  • KC (Korean Registration of Broadcasting and Communications Equipment, Article 58-2 of Radio Waves Act)
  • UKCA (2016 No. 1091, 2016 No. 1101, 2016 No. 1107, 2012 No. 3032)
  • Morocco (Arrête ministériel n° 6404-15)
  • CCC (2020122309111998, CNCA-C23-01 CCC Implementation Rule Explosion-Proof Electrical Products)

What is the continuous isolation threshold provided by the device?

The device provides a continuous isolation voltage rating of 250V using basic insulation across outputs-to-backplane and output-to-output connection paths.

How do environmental conditions affect the maximum current allowance per point?

The maximum current per point is rated at 2 A when operating under an ambient temperature up to 30 degC, which then derates linearly down to 1 A as the temperature reaches 60 degC.

What happens to the outputs when the controller switches into Fault or Program mode?

Each output channel can be configured to hold its last state, turn On, or turn Off. The default parameter configuration enforces an Off state for both modes.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Черно
Country of origin
Съединени щати
Power source
Постоянен ток

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...