Product Overview

The CX1020-N040 (CX1020N040) is a high-precision serial communication interface designed to expand the connectivity of the CX1020 Embedded PC series. This module adds two independent RS232 interfaces, designated as COM3 and COM4, through two standard 9-pin D-sub male connectors. It is an essential component for industrial automation systems that require simultaneous communication with legacy hardware, such as barcode scanners, weighing scales, operator terminals, or older PLC systems. Engineered for seamless integration into the modular CX controller architecture, the CX1020-N040 ensures reliable point-to-point data transmission while maintaining a slim 19 mm profile, allowing for dense control cabinet configurations without sacrificing computational power.

Technical Configuration

The CX1020-N040 hardware is optimized for high-speed serial data exchange, supporting a maximum baud rate of 115 kbaud per channel. The module utilizes the internal system bus for both data communication and power supply, drawing energy through the CX1100-xxxx series power supply modules. To ensure system stability and signal integrity, this interface follows strict configuration logic and is not combinable with the N031 or N041 interface options. Each RS232 port is physically implemented as a 9-pin D-sub plug, providing a mechanically secure connection suitable for high-vibration industrial environments. The fanless and compact design emphasizes long-term maintenance-free operation in demanding plant floor conditions.

Technical Specifications

Attribute Specification Details
Model CX1020-N040
Brand BECKHOFF
Origin Germany
Interfaces 2 x RS232 (COM3 and COM4)
Connection Type 2 x 9-pin D-sub plugs
Max. Baud Rate 115 kbaud
Power Supply Via system bus (CX1100-xxxx)
Operating Temperature 0 to +55 Celsius
Dimensions (W x H x D) 19 mm x 100 mm x 51 mm
Weight approx. 80 g
Protection Rating IP20
Compatibility Not combinable with N031 or N041
Shipping Weight 2.0 kg

Technical FAQs

How are the COM3 and COM4 ports addressed within the TwinCAT environment?

The CX1020-N040 is identified during the hardware scan in TwinCAT System Manager. The ports are automatically assigned as COM3 and COM4 in the operating system (Windows CE or Windows Embedded Standard). You can then use the Serial Communication library in TwinCAT to manage the data buffer and baud rate settings for each port independently.

Is it possible to power an external device through the D-sub pins?

No. The RS232 interface pins follow the standard signal-level conventions. Power for the module itself is drawn from the system bus via the CX1100 power supply, but the D-sub plugs do not provide power contacts for external peripheral devices.

What is the maximum cable length supported by these RS232 ports?

Per the RS232 standard and Beckhoff's industrial specifications, the maximum cable length should not exceed 15 meters to ensure data integrity at higher baud rates. For distances beyond this, using a serial-to-fiber or serial-to-Ethernet converter is recommended.


Engineering & Installation Guide

  • Bus Interface Integrity: Before attaching the CX1020-N040 to the CX1020 CPU or an adjacent module, ensure the internal PC104-style connectors are free of dust and debris. The modules must be snapped together firmly until the locking mechanism engages to ensure a continuous power and data path across the system bus.

  • Conflict Prevention: Verify that your system configuration does not include N031 or N041 modules. These modules share internal address resources; attempting to combine them will cause hardware initialization failures during the boot sequence.

  • Shielding Requirements: In environments with high electromagnetic interference (EMI), use only high-quality shielded D-sub cables. The metal shell of the D-sub plug must be connected to the cable shield to provide a discharge path for noise, preventing data corruption on the COM3/COM4 lines.

 

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Черно
Country of origin
Германия

Наскоро разгледани продукти

Технически знания

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...