1 от 3

GE Fanuc IC695SPF002 RX3i Small Form-Factor Pluggable Transceiver Module

GE Fanuc IC695SPF002 RX3i Small Form-Factor Pluggable Transceiver Module

Only 5 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC695SPF002

  • Country of origin:Съединени щати

  • Product Type: CoMMunication Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 5.8cm x 1.3cm x 1.2cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The IC695SPF002 is an industrial Small Form-factor Pluggable (SFP) optical transceiver module developed for the PACSystems RX3i automation platform. This optical network component is designed to install directly into the dedicated SFP cages of carrier hardware, such as the RX3i PROFINET Scanner (IC695PNS001) and Advanced PROFINET Scanner (IC695PNS101) modules. It enables high-speed, noise-immune fiber-optic connections to bridge local universal RX3i I/O racks across significant distances to a centralized PROFINET I/O Controller.

Operating over the standard 100Base-FX protocol layer, the IC695SPF002 functions at a Fast Ethernet speed of 100 Mbps over multi-mode fiber (MMF) infrastructure. It can transmit data seamlessly up to a physical limit of 2 kilometers without signal degradation. Utilizing light pulses rather than copper electrical currents, this optical transceiver offers total isolation against ground loops, high-voltage surges, and severe electromagnetic or radio frequency interference (EMI/RFI) typically encountered in heavy industrial operating zones. The IC695SPF002 is critical for establishing robust, long-distance network typologies, including line/daisy-chain, star, or Media Redundancy Protocol (MRP) ring networks.

Features

  • Formulated to integrate directly with PACSystems RX3i network modules.
  • Uses the standard 100Base-FX Fast Ethernet communication layer.
  • Runs on multi-mode fiber (MMF) architecture for optimized industrial plant configurations.
  • Supports network infrastructure links over long distances up to 2 kilometers.
  • Compact SFP design enabling hot-plugging into host equipment cages.
  • Fully compatible with host-level diagnostics, indicating link state and error tracking.

Applications

  • Distributing I/O stations across distinct production lines, separate plant buildings, or field locations.
  • High-noise processing environments near variable frequency drives (VFDs), power transformers, and welding fields.
  • Industrial Media Redundancy Protocol (MRP) communication rings for fault-tolerant automation backbones.
  • Water treatment, chemical processing, and power distribution infrastructures requiring optical isolation across long runs.

Ordering Information

Part Number Description
IC695SPF002 RX3i 100Base-FX (fiber 2 km) SFP (Multi-mode fiber - MMF) 

Technical Specifications

Parameter Specification
Manufacturer GE Fanuc / Emerson Automation Solutions 
Model IC695SPF002 (Revision A variant: IC695SPF002A)
Product Type Small Form-factor Pluggable (SFP) Optical Transceiver 
Network Communication Protocol 100Base-FX 
Supported Fiber Cable Media Multi-mode Fiber (MMF) 
Maximum Operational Distance 2 km 
Transmission Rate / Speed 100 Mbps Fast Ethernet 
Fiber Interface Connection Duplex optical port layout 
Host Allocated Current Consumption 0.35 A allocation per active SFP slot 
Environmental Temperature Influence Host modules (PNS) drop maximum operating limits down to 57 degC when 100MB Fiber SFPs are populated 

Connections and Interfaces

Port Element Function / Assignment
Optical TX Port Laser emitter port sending serialized 100Base-FX data signals out to multi-mode fiber 
Optical RX Port Photodiode receiver port capturing arriving data signals from multi-mode fiber 
SFP Interface Connector Multi-pin back connector engaging row lines within the host SFP cage 

Installation Guidelines

  • Optical Radiation Precautions: SFP transceiver units employ an invisible laser beam to form fiber-optic communication signals. Never look directly into an open, unshielded port if a fiber cable is disconnected. Keep empty slots sealed with proper dust caps.
  • High-Temperature Removal Hazards: When the local surrounding air temperature near the host scanner or backplane exceeds 40 degC, the physical external bodies of active SFP transceivers can climb above 70 degC (158 degF). To avoid burning bare skin, use insulated protective gloves or a tool such as needle-nose pliers when extracting a hot transceiver module from its cage.
  • Cable Strain and Bend Limits: Always route the multi-mode fiber cables safely without exceeding the manufacturer's specified minimum bend radius, ensuring optimal optical data transmittal and preventing internal physical fractures.
  • Network Status Verification: Use the integrated diagnostic LEDs on the host module to track network health. The associated port indicator will illuminate solid green when a stable 100 Mbps connection is achieved or light up solid red if an incompatible or uncertified SFP variant is discovered inside the slot.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Fanuc IC695SPF002 RX3i Small Form-Factor Pluggable Transceiver Module

What is the physical link distance limit for this transceiver?

This module operates on 100Base-FX Fast Ethernet over multi-mode fiber infrastructure, supporting safe data transmission up to a maximum distance of 2 kilometers.

How does installing this fiber transceiver alter the thermal limit of the host module?

Populating 100MB fiber SFPs into a host scanner, such as the RX3i PROFINET Scanner, drops its safe maximum ambient operational temperature limit down to 57 degC.

What tools should be used to pull this transceiver out if it is hot?

When the surrounding air temperature exceeds 40 degC, the SFP body can surpass 70 degC. For your safety, use protective gloves or needle-nose pliers rather than bare hands during removal.

What does a solid red light on the scanner port indicator indicate?

A solid red light on port 3 or port 4 of the host PROFINET scanner indicates a port-level error, such as the insertion of an incompatible SFP device.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сребърен
Country of origin
Съединени щати
Networking standards
IEEE 802.3

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...