1 от 1

Mitsubishi Electric FR-A840-00170-2-60 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-00170-2-60 FR-A800 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A840-00170-2-60

  • Country of origin:Съединени щати

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 8000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Designed for precision speed and torque control in heavy industrial environments, the Mitsubishi Electric FR-A840-00170-2-60 is a high-performance three-phase variable frequency drive belonging to the premium FR-A800 series. This standard model operates on a 400V class input and is engineered with an SLD (Super Light Duty) rated current rating of 17 A. To ensure long-term reliability in harsh operational environments, the unit features a specialized protective conformal circuit board coating (Class 3C2) without plated conductors, providing superior resistance to corrosive gases and moisture. Its robust cooling system relies on forced air circulation to maintain optimal thermal conditions inside enclosed electrical cabinets.

Features

  • Advanced Real Sensorless Vector Control and Vector Control capabilities for precise speed and torque regulation.
  • Specially coated circuit boards (conforming to IEC 60721-3-3 Class 3C2) for enhanced environmental resistance.
  • Dual-loop PID control and built-in PLC functionality to handle localized automation sequences.
  • Flexible overload capacity modes enabling optimization for various industrial load profiles.
  • Integrated safety stop function complying with EN ISO 13849-1 Category 3 / PLd and IEC 60204-1.
  • Forced air cooling system designed with long-life cooling fans for minimized maintenance overhead.

Applications

  • Conveyor Systems: Precise speed control and torque limits for high-inertia material handling applications.
  • Pumping and Ventilation: Energy-efficient flow control and pressure regulation using integrated PID algorithms.
  • Extruders and Mixers: High starting torque capabilities and excellent speed stability under fluctuating loads.
  • Hoists and Cranes: Smooth mechanical brake sequencing and load-torque matching routines.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number FR-A840-00170-2-60
Series FR-A800
Voltage Class Three-phase 400V class
Rated Input AC Voltage/Frequency Three-phase 380 to 500V AC, 50Hz / 60Hz
Permissible AC Voltage Fluctuation 323 to 550V AC, 50Hz / 60Hz
SLD Rated Inverter Current 17.0 A
Conformal Board Coating Standard 3C2 coating (conforms to IEC 60721-3-3)
Plated Conductor None
Protective Structure IP20 (Enclosed type)
Cooling System Forced air cooling
Unit Net Weight 6.7 kg
Shipping Weight (Calculated) 8.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

This model serves as a modern replacement for the legacy FR-A740 series. While physical footprint changes are minor, the control terminal layout is optimized. Parameter configurations from older FR-A740 units can be seamlessly imported using the FR Configurator2 software utility. Always check terminal strip physical spacing if replacing an older generation drive inside a tight control panel.

Application Pitfalls & Engineering Notes

The -60 suffix specifies a 3C2 conformal board coating. This is highly recommended for wastewater, pulp and paper, or chemical processing sites. However, because this model is designed without plated conductors, it should not be exposed to severe atmospheric concentrations of chlorine or sulfur salts that exceed Class 3C2 specs. If operating under high ambient temperatures, thermal derating curves must be applied to prevent overtemperature faults (E.THT).

Commissioning & Wiring Tips

Always ensure that control signals are isolated from high-power cable runs. Keep control and power cables in separate wire trays or use shielded cables grounded at the drive end only. False ground fault trips (E.GF) can occur if leakage currents from long motor cable runs exceed the threshold; installing an output dV/dt filter or a common-mode choke will mitigate this issue during commissioning.

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK AND EQUIPMENT DAMAGE. Ensure all main AC power sources are completely disconnected, locked out, and tagged out before installing or servicing this drive. Wait at least 10 minutes after disconnecting power to allow the DC bus capacitors to fully discharge. Verify zero voltage across terminals P/+ and N/- before touching any electrical terminals.
1
Enclosure Mounting: Mount the inverter vertically on a flat, non-flammable surface inside an IP20 or higher enclosure. Ensure minimum clearance distances (50 mm above and below, 10 mm on sides) to facilitate unobstructed airflow through the cooling heatsinks.
2
Power Input and Output Wiring: Connect the three-phase AC mains supply to terminals R/L1, S/L2, and T/L3. Connect the motor leads to terminals U, V, and W. Under no circumstances should input mains power be connected to the output terminals U, V, or W, as this will destroy the internal IGBT modules.
3
Grounding Connection: Connect the ground terminal of the drive securely to the system PE (Protective Earth) ground. Ground resistance must be 10 Ohms or less for 400V class installations to satisfy both safety standards and high-frequency noise suppression demands.

What does the -60 suffix mean for this inverter?

The -60 suffix indicates that the control and power circuit boards are treated with a conformal coating conforming to IEC 60721-3-3 Class 3C2, and it does not feature plated conductors.

What is the recommended grounding practice to prevent leakage current trips?

Ensure a dedicated Class D ground wire is connected directly to the inverter grounding terminal. Avoid loop configurations with other equipment to suppress high-frequency common-mode noise.

Can parameters from an older FR-A740 model be imported?

Yes, using FR Configurator2 software, you can convert and import parameter files from older FR-A700 series drives directly into this FR-A800 series unit.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Съединени щати

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...