1 от 1

Mitsubishi Electric GT2510-VTBD GOT2000 Series Graphic Operation Terminal

Mitsubishi Electric GT2510-VTBD GOT2000 Series Graphic Operation Terminal

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: GT2510-VTBD

  • Country of origin:Съединени щати

  • Product Type: HMI Operator Panels

  • Payment: T/T, Western Union

  • Weight: 8g

  • Dimensions: 303 mm x 218 mm x 52 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Tasked with executing demanding visualization and control tasks in medium-to-large automation environments, the Mitsubishi Electric GT2510-VTBD serves as a high-performance 10.4-inch graphic operation terminal within the GOT2000 portfolio. This human-machine interface (HMI) utilizes a high-resolution TFT color display to deliver crisp process schematics, diagnostic screens, and interactive control elements. Engineered for seamless integration into diverse control architectures, the device features robust onboard processing capabilities and flexible communications, enabling real-time status updates and minimizing system latency. Its hardware configuration features physical protection barriers, optimizing the unit for prolonged deployment inside industrial control enclosures subjected to temperature fluctuations and mechanical stress.

Features

  • High-Resolution Display: 10.4-inch TFT LCD screen displaying up to 65,536 colors with a clear VGA (640 x 480) resolution for precise data representation.
  • Analog Resistive Touch: High-durability analog resistive screen enabling fine control inputs and multi-touch capabilities such as zooming and scrolling.
  • Comprehensive Connectivity: Built-in ports for Ethernet (10BASE-T/100BASE-TX), RS-232, RS-422/485, and USB host/device connections.
  • Industrial Protection: IP67F rating on the front panel when properly mounted, offering resistance against water spray, oil mist, and non-conductive dust.
  • Data Portability: Integrated SD card slot supports high-speed system backups, trend logging, recipes, and user program transfers.

Applications

  • Automotive assembly automation and conveyor control networks.
  • Water treatment, municipal pump stations, and fluid storage monitoring.
  • Food and beverage packaging lines requiring regular washdowns.
  • Chemical processing and batch-mixing terminal supervision.

Technical Specifications Table

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number GT2510-VTBD
Series Name GOT2000 (GT25)
Display Size & Type 10.4-inch TFT Color Display
Resolution VGA (640 x 480 pixels)
Input Supply Voltage 24 VDC (+25%, -20%)
Power Consumption (Max) 33 W or less
Inrush Current 5 A or less (20 ms at 25 degC, maximum load)
Withstand Voltage 350 VAC for 1 minute (between power terminals and ground)
Operating Temperature 0 to 55 degC (ambient temperature)
Storage Temperature -20 to 60 degC
Operating Humidity 10% to 90% RH, non-condensing
External Dimensions (W x H x D) 303 mm x 218 mm x 52 mm
Net Weight 2.1 kg (excluding mounting brackets)
Shipping Weight (Calculated) 3.5 kg
Country of Origin Japan

Connections and Interfaces

Interface Port Function / Assignment
Ethernet Port 1 channel (10BASE-T/100BASE-TX) for host PLC networks and PC connection
RS-232 Port 1 channel (D-sub 9-pin male) for serial device communication and barcode readers
RS-422/485 Port 1 channel (D-sub 9-pin female) for serial connection to PLCs or temperature controllers
USB Host 1 channel (Type-A) for USB memory storage, keyboard, or mouse integration
USB Device 1 channel (Mini-B) for screen program uploads, downloads, and PC communication
Power Terminal Block M3 screw terminals for 24 VDC connection and Functional Ground (FG)

Empirical Engineering Insights

Alternative Models & Compatibility

The GT2510-VTBD is a direct evolutionary path from legacy GT1575 and GT1675 terminals. While panel cutout dimensions remain identical, physical alignment brackets (GT15-10COUT-AGP) must be utilized if converting from certain non-GOT panels. Screen projects created in GT Designer3 require minimal adjustment, though you must configure the software to translate old serial communication drivers to the modern Ethernet protocols supported natively on this hardware revision.

Application Pitfalls & Engineering Notes

When executing high-speed logging directly to the SD card, ensure you write to an industrial-grade SLC card with write-wear monitoring enabled. Multi-level cell (MLC) consumer cards can suffer structural block fatigue within weeks of continuous write cycles. Additionally, verify that the 24VDC supply voltage does not drop below 19.2VDC during high peak load phases (e.g., when motor contactors engage on the same DC bus) to prevent involuntary hardware resets.

Commissioning & Wiring Tips

For reliable communications, the functional ground (FG) terminal must be terminated to a clean Class-D ground point with a wire length of less than 1 meter. Under intense electromagnetic interference (EMI) environments, such as those with neighboring VFDs, shield the RS-422/485 serial cables and ground the shield at only one end to prevent ground loops from corrupting the communication packet stream.

Installation Guidelines

CRITICAL WARNING

Ensure all incoming power supplies (both terminal power and connected network lines) are entirely de-energized and locked out before attempting physical installation or terminal termination. Failure to isolate power can result in accidental transient discharge, damaging the internal optical isolation circuits of the RS-232 and RS-422 ports.

1
Verify the panel cutout meets the required dimensions of 289 mm (W) x 200 mm (H) with a maximum panel thickness of 5 mm.
2
Inspect the water-resistant rubber gasket embedded in the outer rim of the HMI unit. Replace immediately if crimped, dirty, or damaged to ensure the IP67F seal remains intact.
3
Slide the terminal into the panel cutout and secure it from the rear using the four supplied mounting brackets. Tighten the mounting screws to a torque of 0.36 N·m in a cross pattern to prevent screen bezel distortion.
4
Terminate the 24VDC power connections using M3 solderless terminals (such as RAV1.25-3 or V2-S3.3), and apply a final tightening torque between 0.5 and 0.8 N·m to the terminal block screws.

Can I upgrade an existing GT1575 terminal directly to the GT2510-VTBD?

Yes. The physical panel cutout requirements for both models are identical. Screen conversion can be managed within the GT Designer3 development environment.

What happens if the mounting brackets are tightened beyond the recommended torque?

Tightening the mounting screws above 0.36 N.m can warp the front bezel, which compromises the protective IP67F front panel seal and may affect touch screen accuracy.

What wire size and terminal types should be used for the 24VDC power supply connection?

Use wire sizes between 0.75 and 2 mm2 with M3 crimp terminals (such as RAV1.25-3 or V2-S3.3). Tighten the screw terminals to 0.5 to 0.8 N.m.

How do I secure the HMI's memory functions during power failures?

The system features internal non-volatile memory for system files, while battery-backed SRAM maintains alarms and recipe variables. Project data can also be backed up to an SD card.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Съединени щати

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...