Facilitating high-speed digital-to-analog conversion within CC-Link IE Field networks, the Mitsubishi Electric NZ2GF2BN-60DA4 serves as a high-precision remote device station featuring four independent analog output channels. This module converts 16-bit signed binary digital values into precise voltage or current signals to drive field actuators, control valves, and speed regulators in complex industrial automation architectures.

Key Features

  • Four High-Resolution Channels: Supports independent configuration for voltage (-10 to 10 VDC) or current (0 to 20 mADC) outputs.
  • Robust Signal Isolation: Features photocoupler isolation between the communication system and analog outputs, alongside transformer isolation between the power supply and analog circuits.
  • Output Short-Circuit Protection: Integrated protection circuitry prevents module damage from field wiring faults or shorted loads.
  • Flexible Network Topology: Dual RJ45 ports support line, star, and ring topologies on CC-Link IE Field networks.
  • Removable Terminal Block: Two-piece 18-point terminal block simplifies pre-wiring, commissioning, and hot-swapping procedures.

Industrial Applications

  • Proportional control valve positioning in hydraulic and pneumatic systems.
  • Speed reference distribution to variable frequency drives (VFDs).
  • Setpoint transmission to SCR power controllers in industrial heating applications.
  • Remote signal generation for paper, steel, and textile tension control systems.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Number NZ2GF2BN-60DA4
Product Type Main D/A Converter Module
Station Type Remote device station
Analog Output Channels 4 channels (4 points)
Digital Input Resolution 16-bit signed binary (-16384 to 16383, -288 to 12287, -12288 to 12287)
Voltage Output Range -10 to 10 VDC (External load: 1k ohm to 1M ohm)
Current Output Range 0 to 20 mADC (External load: 0 ohm to 600 ohm)
Output Protection Short-circuit protected
Isolation (Comm to Analog) Photocoupler isolation
Isolation (Power to Analog) Transformer isolation
Isolation (Channel to Channel) Non-isolated
Withstand Voltage 500 VAC for 1 minute (between power/comm and analog outputs)
Communication Interface RJ45 connector (CC-Link IE Field)
Power Supply Terminal M2.5 screw terminal block (Tightening torque: 0.5 to 0.6 Nm)
I/O Terminal Block 18-point two-piece terminal block, M3 screws (Tightening torque: 0.43 to 0.57 Nm)
Module Weight 0.29 kg
Shipping Weight (Calculated) 1.50 kg

Connections and Interfaces

Interface Type Terminal / Pin Assignment Functional Assignment
RJ45 Ports PORT1 / PORT2 CC-Link IE Field Network connection (supports line/ring topologies)
Power Terminal Block 24V, 0V, FG Module 24 VDC power input and Frame Ground
18-Point Terminal Block V+, I+, COM (Channels 1 to 4) Analog voltage/current outputs and common reference lines

Alternative Models & Compatibility

The NZ2GF2BN-60DA4 is specifically designed for CC-Link IE Field networks and is not compatible with legacy CC-Link or CC-Link IE Field Basic protocols. Ensure that the master station PLC is equipped with a compatible CC-Link IE Field Master/Local module (such as the RJ71GF11-T2 or QJ71GF11-T2) and that the correct CSP+ profile is registered in GX Works2 or GX Works3 prior to network configuration.

Application Pitfalls & Engineering Notes

Because there is no channel-to-channel isolation on this module, all analog output common (COM) terminals are internally tied together. Connecting field devices with differing ground potentials can create ground loops, resulting in signal drift, measurement errors, or hardware degradation. If channel-to-channel isolation is required by your application, external signal isolators must be installed between the module outputs and the field devices.

Commissioning & Wiring Tips

Always use high-quality double-shielded twisted-pair cables for analog signal runs. Ground the shield at only one end (typically the control panel side) to prevent ground loop currents. Ensure the Frame Ground (FG) terminal on the power supply block is connected to a dedicated class-D ground (100 ohms or less) using a minimum of 2 mm2 wire to minimize high-frequency noise interference from adjacent variable frequency drives.

Installation Guidelines

CRITICAL WARNING: Prior to commencing any installation, wiring, or maintenance activities, ensure all incoming AC and DC power sources to the control panel are completely de-energized. Verify the absence of voltage using a calibrated digital multimeter. Failure to isolate power can result in severe electrical shock, equipment destruction, or erratic control system behavior.
1
Mount the module securely to a 35mm DIN rail, ensuring the DIN rail hook is locked in place.
2
Connect the CC-Link IE Field Ethernet cables to PORT1 and PORT2, ensuring the RJ45 connectors click firmly into position.
3
Wire the 24VDC module power supply and FG to the dedicated M2.5 terminal block, tightening to the specified torque of 0.5 to 0.6 Nm.
4
Connect the analog output signal wires to the 18-point removable terminal block, ensuring M3 screws are torqued to 0.43 to 0.57 Nm, then plug the block securely into the module.

Does the NZ2GF2BN-60DA4 support channel-to-channel isolation?

No, the module features photocoupler isolation between communication and analog circuits, and transformer isolation between power and analog circuits, but the individual analog output channels are non-isolated from each other.

What is the maximum load resistance supported for current output mode?

In current output mode (0 to 20 mADC), the module supports an external load resistance range of 0 ohm to 600 ohm.

How do I configure this module in GX Works3?

You must import the corresponding CSP+ profile file for the NZ2GF2BN-60DA4 into GX Works3, then add the module to your CC-Link IE Field network configuration map.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Съединени щати

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...