1 от 1

Omron NX-RS1201 NX Series Load Cell Input Unit

Omron NX-RS1201 NX Series Load Cell Input Unit

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NXRS1201

  • Country of origin:Япония

  • Product Type: Load Cell Input Units

  • Payment: T/T, Western Union

  • Weight: 70g

  • Dimensions: 12 mm x 100 mm x 71 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

Engineered for high-speed, high-accuracy weighing applications, the Omron NX-RS1201 operates as a high-performance weight and force measurement module within the Sysmac automation platform. This high-performance module interfaces directly with strain-gauge load cells, converting raw analog force signals into highly precise digital data. Designed for seamless integration into EtherCAT and EtherNet/IP networks via NX-series coupler units, the Omron NX-RS1201 features an ultra-fast conversion cycle of 125 microseconds and a 24-bit A/D converter. Its support for Synchronous I/O refreshing allows exact timing coordination with motion control processes, making it highly effective for dynamic checkweighers, filling systems, and tension control applications.

Key Features

  • Ultra-precise 24-bit analog-to-digital conversion resolution.
  • High-speed 125-microsecond conversion cycle for real-time force measurement.
  • Flexible I/O refreshing options including Synchronous, Free-Run, and Task Period Prioritized refreshing.
  • Built-in stable 5 VDC (+/- 10%) load cell excitation voltage output.
  • Space-saving 12 mm wide profile to minimize DIN rail footprint.
  • Vibration-resistant screwless push-in clamping terminal block (16 points) for rapid field installation.

Applications

  • High-speed industrial checkweighers and packaging machinery.
  • Continuous filling, dosing, and batching systems.
  • Web tension measurement and winding control in paper and film processing.
  • Material testing machines and press-fit force monitoring systems.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Omron
Model Number NX-RS1201
Product Type Load Cell Input Unit
Number of Points 1 Channel
A/D Converter Resolution 24 bits
Conversion Cycle 125 microseconds
Input Range -5.0 to 5.0 mV/V
Input Conversion Range -5.5 to 5.5 mV/V
Load Cell Excitation Voltage 5 VDC (+/- 10%), 60 mA maximum output current
Zero / Gain Adjustment Range -5.0 to 5.0 mV/V
Nonlinearity +/-0.01% of full scale
Zero Drift +/-0.1 microvolt per degC RTI (Refer to Input)
Gain Drift +/-10 ppm per degC
Warm-Up Period 30 minutes minimum
External Connection Terminals Screwless clamping terminal block (16 terminals)
Dimensions (W x H x D) 12 mm x 100 mm x 71 mm
Product Weight 0.07 kg
Shipping Weight (Calculated) 1.00 kg (including protective packaging)
Country of Origin Japan

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-RS1201 is fully integrated into the Omron Sysmac platform via NX-series Bus Couplers. When replacing legacy analog input modules, ensure that the target Sysmac Studio project configuration is updated to support this unit's 24-bit output structure. Firmware compatibility must be verified with the controller unit: an NJ-series, NX-series, or NY-series controller requires firmware version 1.10 or higher for full Synchronous I/O operational modes.

Application Pitfalls & Engineering Notes

Because of its ultra-high resolution, the 24-bit A/D converter is highly sensitive to ambient temperature changes. For applications requiring precise measurements, the module requires a full 30-minute warm-up period to stabilize thermal drift coefficients. If the control panel is located near heat-generating equipment (such as variable frequency drives or large transformers), forced ventilation is highly recommended to maintain a steady ambient temperature and prevent drift.

Commissioning & Wiring Tips

To maintain maximum measurement integrity, avoid running the load cell signal cables in parallel with high-voltage AC power lines. Utilize double-shielded, twisted-pair cables for excitation and signal paths. The cable shield must be terminated at a single point—preferably at the functional ground terminal of the NX-series system—to prevent ground loops that introduce electrical noise to the microvolt-level inputs.

Installation Guidelines

CRITICAL SAFETY WARNING

Turn off all power supplies to the PLC rack and field devices before installing, removing, or wiring the module. Failure to de-energize equipment can result in electrical shock, equipment damage, or erratic system behavior.

1
Align the guide hooks on the side of the NX-RS1201 with the adjacent module or bus coupler, then slide the unit onto the DIN rail until it clicks securely into place.
2
Strip the load cell connection wires to the recommended length (typically 8 to 10 mm) and insert them directly into the push-in screwless clamp terminals. Ensure the Excitation (+/-) and Signal (+/-) polarities match your load cell specifications.
3
Connect the functional ground wire to the designated grounding terminal and apply power to the system. Allow the unit to warm up for 30 minutes before executing the zero-point and span calibration through Sysmac Studio.

What is the resolution of the A/D converter on the NX-RS1201?

The module is equipped with a high-performance 24-bit A/D converter, providing superior resolution for microvolt-level force and weight measurement.

How fast is the conversion cycle for this load cell module?

The unit features an ultra-fast conversion cycle of 125 microseconds, making it suitable for dynamic and high-speed weighing systems.

Does this module require a specific warm-up period before calibration?

Yes, to ensure accurate measurement and minimize thermal drift errors, a minimum warm-up period of 30 minutes is required after power-up.

What type of terminals are used for field connections?

It utilizes a 16-point screwless clamping terminal block, facilitating reliable, tool-free wiring that is highly resistant to industrial vibrations.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Япония

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация