1 z 1

Honeywell 900A01-0202 HC900 Analog Input Module

Honeywell 900A01-0202 HC900 Analog Input Module

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 900A01-0202

  • Country of origin:United States

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Processing multi-channel analog signals is simplified using the Honeywell 900A01-0202, a high-performance, 8-channel isolated analog input module designed for the HC900 process controller platform. This module allows direct connection to a wide range of industrial sensors, featuring universal channel configuration to minimize hardware footprint and simplify system design. Each of the eight channels can be individually programmed to accept different signal types, including thermocouples, RTDs, voltage, current, resistance, and slidewires, providing high application flexibility in demanding process environments.

The Honeywell 900A01-0202 features robust galvanic isolation to prevent ground loop currents from degrading signal integrity. With channel-to-channel and channel-to-logic isolation, the module maintains stable operation and high measurement accuracy even in electrically noisy industrial settings. Integrated diagnostics, such as thermocouple break detection via current pulse, ensure rapid troubleshooting and reduced system downtime.

Features

  • Eight independent, galvanically isolated analog input channels.
  • Universal input support including mV, V, mA, RTD, Thermocouple, Ohms, and Slidewire.
  • Robust isolation: 400 VDC point-to-point and 1000 VDC input-to-logic.
  • High-efficiency noise rejection with >130dB common mode rejection at 120VAC.
  • Active sensor diagnostics with automatic thermocouple break detection.
  • RTD inputs isolated in pairs for optimal signal processing and cabling efficiency.

Applications

  • Thermal processing and industrial furnace monitoring.
  • Oil and gas refining and pipeline monitoring.
  • Chemical processing and reactor temperature tracking.
  • Power generation plant parameter monitoring.
  • Water and wastewater treatment facility automation.

Technical Specifications

Manufacturer Honeywell
Part Number / Model 900A01-0202
Series HC900 Control System
Module Type Analog Input Module
Number of Channels 8 (isolated)
Input Configurations mV, V, T/C, RTD, Ohms, mA, Slidewire (configurable per channel)
Input Impedance (T/C and mV) 10 megohms
Input Impedance (Volts) >1 megohm
Input Impedance (mA) 250 ohms
Galvanic Isolation (Point-to-Point) 400 VDC
Galvanic Isolation (To Logic) 1000 VDC
Series Mode Noise Rejection >60dB
Common Mode Noise Rejection >130dB at 120VAC
Over-Range Limit (Linear/Volts) +/- 10%
Over-Range Limit (Non-Linear/TC, RTD) +/- 1%
Sensor Break Detection Thermocouple break detection via current pulse
Shipping Weight 2 kg

Connections and Interfaces

Connection Type Specification / Layout
RTD Wiring configuration Isolated in pairs (IRTD is common to two inputs)
Thermocouple Inputs Cold junction compensation; maximum 100 Ohms/Leg
RTD Compatibility PT100 3-wire (40 ohms balanced max), 100/500/1000 RTD (100 Ohms/Leg), 10 Ohm Cu (10 Ohms/Leg)
Slidewire Range 100 to 6,500 Ohms (10% of total resistance/leg)

Installation Guidelines

  • Mounting: Ensure the module is securely seated in the HC900 rack chassis slot and the module retaining screws are fully tightened.
  • Wiring: Route low-voltage analog input signal cables away from high-voltage AC power distribution wiring to prevent electromagnetic coupling.
  • Shielding: Use shielded twisted-pair cabling for all sensor connections. Connect shields to the chassis ground bar at the controller end only.
  • Thermal Management: Maintain recommended clearance spaces around the rack assembly to ensure natural convection cooling matches environmental specifications.

What sensor types can be connected to the Honeywell 900A01-0202 module?

The Honeywell 900A01-0202 is a universal analog input module that supports thermocouples, RTDs (including PT100), millivolt (mV) signals, standard DC voltage (V), DC current (mA), resistance (Ohms), and slidewire inputs.

What isolation levels does the 900A01-0202 input module provide?

The module provides galvanic isolation of 400 VDC point-to-point (channel-to-channel) and 1000 VDC isolation from the input channels to the controller's logic circuit. Note that RTD inputs are isolated in pairs.

How does the module handle sensor diagnostics, such as broken thermocouple wires?

The 900A01-0202 module uses an active current pulse method to perform real-time sensor break detection on thermocouple input channels.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...