1 z 1

Honeywell TK-FFIF01 C200 Fieldbus Interface Module

Honeywell TK-FFIF01 C200 Fieldbus Interface Module

Only 2 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TK-FFIF01

  • Country of origin:United States

  • Product Type: Fieldbus Interface Module

  • Payment: T/T, Western Union

  • Weight: 420g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The TK-FFIF01 is a chassis-mounted communication interface component operating as a Fieldbus Interface Module (FIM2) within the Honeywell C200 and Experion distributed control system (DCS) architectures. This device establishes deterministic data highways between the host controller backplane and field-level instruments executing decentralized control strategies. Equipped with two independent, digital communication links, it handles token passing, schedule execution, and diagnostic frame transmission across standard industrial networks. The module is built with conformally coated electronic assemblies to resist atmospheric contamination and humidity, ensuring reliable digital network integration and continuous parameter exchange for intelligent field instrumentation in processing environments.

Features

  • Dual independent communication links for field-level network routing.
  • Conformal coating protection on internal circuit boards to withstand harsh environments.
  • Specialized CIOM-A hardware platform form factor for direct rack integration.
  • Real-time diagnostic data tracking and status mapping to master controllers.

Applications

  • Intelligent field device configuration and monitoring in process loops.
  • Distributed Control Systems (DCS) digital network communication bridging.
  • Instrumentation mapping inside chemical, oil and gas, and wastewater facilities.
  • Asset management integration utilizing digital field network diagnostics.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model TK-FFIF01 (Product text reference: TK-FFIFF01)
Product Type Fieldbus Interface Module (FIM2)
Product Series C200 Chassis I/O (CIOM-A)
Number of Links 2 Links
Physical Protection Coated (Conformal Coating)
Weight 0.42 Kg
Shipping Weight 1.5 Kg
Country of Origin United States / Global Operations

Installation Guidelines

Grounding and Shielding

Ensure the host C200 chassis is bonded directly to the primary industrial instrumentation grounding bus using a low-impedance copper conductor. Field network cable shields must follow strict segment termination protocols, grounding at designated external terminal blocks to suppress cross-talk and high-frequency noise.

Handling and ESD Protection

The internal communication circuitry is susceptible to electrostatic discharge. Field technicians must utilize an approved, bonded static-dissipative wrist strap during unboxing, address selection, or final installation into the controller chassis slot.

Alignment and Insertion

Align the circuit card edges with the molded plastic chassis tracks. Slide the module completely into the assigned backplane connector slot until the latching mechanism is fully engaged, and secure the mechanical fasteners to maintain proper contact pressure under continuous operational vibration.

Environmental Considerations

The module features a conformal coating layer for improved defense against corrosive atmospheres. Ensure ventilation spaces inside the enclosure remain clean and unblocked to prevent regional temperature spikes from exceeding standard system operating parameters.

FAQ

What is the core purpose of this interface module?

It functions as a communication gateway bridging the central controller backplane with field-level digital instruments.

How many network lines can a single hardware assembly manage?

The module is designed with two distinct links to coordinate digital device loops independently.

What does the term coated mean in the technical details?

It indicates the internal printed circuit boards feature a conformal coating layer to shield components against humidity and airborne contaminants.

Is this device compatible with standard C200 chassis hardware?

Yes, it is designed with the standard CIOM-A form factor for seamless slot insertion into compatible racks.

What is the net physical weight of this standalone unit?

The individual unboxed module has a net physical weight of exactly 0.42 Kg.

Does this component operate as a standalone process loop controller?

No, it is a dedicated communication interface module that routes digital field parameters back to a master controller.

What precautions are necessary regarding static electricity when handling this unit?

Technicians must follow proper ESD control protocols, including using grounded wrist straps, before executing maintenance.

Does this hardware package include external terminal blocks?

The base module fits into standard rack backplanes; external wiring connectors must be sourced separately based on physical architecture layouts.

How is the hardware protected against physical movement within the rack?

It uses standard mechanical retention locks that clamp directly onto the chassis faceplate assembly.

What is the total mass of the module inside its standard transport packaging?

The complete shipping weight including the protective outer carton is specified at 1.5 Kg.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizace HMI Bailey INFI 90 Symphony běžících na OpenVMS Alpha

Praktický průvodce výměnou zastaralých operátorských stanic Bailey Symphony běžících na OpenVMS Alpha. Porovnává emulaci Alpha, migraci OpenVMS na x86, přemostění OPC a postupnou modernizaci ABB.

Proč jsou údaje o údržbě nezbytné pro průmyslovou spolehlivost

Údaje o údržbě propojují pracovní příkazy, signály ze senzorů, historii majetku, náklady a znalosti techniků. Správné využití těchto dat zlepšuje plánování, spolehlivost, prediktivní údržbu, kontrolu...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...