1 von 1

Beckhoff CX2030-0121 CX2000 Series Basic CPU Module

Beckhoff CX2030-0121 CX2000 Series Basic CPU Module

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: CX2030-0121

  • Herkunftsland:Deutschland

  • Produkttyp: PLC CPU Modules

  • Zahlung: T/T, Western Union

  • Gewicht: 500g

  • Abmessungen: 144 mm x 99 mm x 91 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Executing complex automation tasks requiring substantial processing power is the primary role of the Beckhoff CX2030-0121 embedded PC module. This unit integrates a dual-core Intel Core i7 2610UE processor running at 1.5 GHz, delivering high-speed computation directly on the DIN rail. Equipped with dual independent 10/100/1000 Mbit/s RJ45 ports, a dedicated DVI-I diagnostic interface, and four USB 2.0 ports, the controller functions as a high-density processing hub for TwinCAT runtime environments. The design utilizes passive cooling under standard operating configurations, maximizing physical durability in challenging environments while eliminating moving wear-and-tear parts.

Features

  • Dual-Core Processing: High-efficiency Intel Core i7 2610UE 1.5 GHz CPU delivers high performance for simultaneous motion control and HMI tasks.
  • Dual Bus Compatibility: Automatic recognition of K-bus (standard Beckhoff Bus Terminals) and E-bus (EtherCAT Terminals) via the attached power supply module.
  • Non-Volatile Memory: 128 kB of integrated NOVRAM ensures retain data is preserved without requiring battery backing during power cycle losses.
  • Industrial Diagnostic I/O: Onboard LEDs monitor power, TwinCAT status, CFast access, and network bus connection states.
  • Expandable Storage & Memory: Ships with 2 GB DDR3 RAM and a configurable CFast flash card slot (20 GB or 40 GB variants depending on operational requirements).

Applications

  • High-speed multi-axis motion synchronization systems.
  • Centralized plant automation and main edge-gateway nodes.
  • Complex packaging line control involving high-density digital and analog I/O maps.
  • Test benches and laboratory measurement systems using microsecond-level EtherCAT sampling.

Technical Specifications Table

Parameter Specification Value
Manufacturer Beckhoff
Model Number CX2030-0121
Processor Intel Core i7 2610UE 1.5 GHz (Dual Core)
Main Memory 2 GB DDR3 RAM
Persistent Memory 128 kB NOVRAM
Interfaces 2 x RJ45 (10/100/1000 Mbit/s), 1 x DVI-I, 4 x USB 2.0
Bus Connection Via power supply module (E-bus / K-bus with auto-detection)
TwinCAT Platform Level Mid Performance (60)
Operating System Windows Embedded Standard 7 P
Power Supply Input 24 V DC (-15% / +20%)
Max Power Consumption 27 W
Protection Rating IP20
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
Approvals CE, UL
Dimensions (W x H x D) 144 mm x 99 mm x 91 mm
Net Weight 1165 g
Shipping Weight (Calculated) 3 kg (with protective packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The CX2030 series acts as a direct hardware upgrade step over the CX2020 single-core units. Due to the architecture requirements of Windows Embedded Standard 7, Ensure that existing storage media cards are formatted with identical partition configurations when hot-swapping older system drives. TwinCAT 3 setups operating on this device run on Platform Level 60 (Mid Performance).

Application Pitfalls & Engineering Notes

Though passively cooled in many standard mount schemes, high-density cabinet layouts with ambient temperatures above 45 degC require maintaining a minimum of 30 mm vertical clearances. Blocking ventilation channels beneath or above the module will accelerate the thermal throttling threshold of the Core i7 CPU, dropping its operating cycle from 1.5 GHz down to fail-safe parameters.

Commissioning & Wiring Tips

Always verify that the auxiliary grounding block on the DIN rail is bonded securely to the panel backplate. The CX2030-0121 uses structural grounding connections through the DIN rail springs. Failure to establish a low-impedance ground path can result in intermittent packet loss on gigabit RJ45 interfaces and bus synchronization faults.

Installation Guidelines

CRITICAL WARNING:

Do not insert or extract CFast storage media while control power is applied to the system bus. Turn off the primary 24V DC input supply and verify that all status LEDs are completely dark before removing any interface modules or terminal block lines.

1

Mount the module vertically onto a grounded DIN rail (EN 60715) by snapping it firmly into position until the metal locking latches engage.

2

Slide adjacent I/O bus terminals directly onto the right side of the module housing until the internal E-bus or K-bus slide contacts click home.

3

Connect network interfaces, DVI display lines, and peripherals before providing a stabilized 24V DC feed to the power supply terminal module.

Loading product navigation…

Can the RAM on the CX2030-0121 module be upgraded in the field?

No, the 2 GB DDR3 RAM is integrated directly onto the system board and must be configured ex factory if upgrading to the 4 GB option.

How does this CPU module interface with K-bus and E-bus terminals?

The CPU automatically detects whether K-bus (standard Beckhoff bus terminals) or E-bus (EtherCAT terminals) are connected when plugged into the companion power supply module.

What TwinCAT 3 performance class applies to this model?

The CX2030-0121 operates within TwinCAT 3 Platform Level 60 (Mid Performance tier).

What is the function of the built-in 128 kB NOVRAM?

NOVRAM is persistent non-volatile RAM that automatically preserves critical operational status values during power failures without requiring an external backup battery.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe als Ersatz für Flüssigkeiten: Praktisches Tutorial

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...