Description

Designed for high-density analog signal acquisition, the EL3008 EtherCAT Terminal processes up to eight single-ended voltage signals in the range of -10 V to +10 V. Each analog input channel features a 12-bit resolution, mapped into a 16-bit process image (including sign representation) for standard compatibility with EtherCAT control environments. Powered directly through the E-bus, this compact 12 mm module provides electrical isolation between the internal E-bus circuitry and the field-side signal lines to ensure high signal integrity and system robustness in demanding electrical environments.

The EL3008 features configurable conversion times and built-in digital filters (FIR/IIR) to help suppress high-frequency noise and match system-specific acquisition requirements. Integrating limit value monitoring and overload detection directly within the process data, this module simplifies diagnosis and monitoring tasks for modern PLC, DCS, and industrial automation networks.

Features

  • Eight independent single-ended analog input channels in a compact terminal housing.
  • Voltage measurement range from -10 V to +10 V with 12-bit conversion resolution.
  • Fast internal conversion time with a default rate of 1.25 ms (configurable and multiplexed).
  • Integrates software-activatable FIR and IIR filters for effective signal conditioning.
  • Advanced diagnostics including limit value monitoring and channel-specific overload indication in process data.
  • Robust electrical isolation of 500 V between the E-bus and signal channels.
  • High-density spring-loaded cage connection system for quick and secure field wiring.

Applications

  • Multi-point voltage monitoring in process plants and manufacturing systems.
  • Sensor and transducer data acquisition in factory automation.
  • Control loop feedback in mechanical engineering and test benches.
  • Sub-assembly integration within centralized EtherCAT I/O architectures.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL3008
Product Type EtherCAT Terminal (Analog Input Module)
Number of Inputs 8 (single-ended)
Signal Voltage Range -10 V to +10 V
Resolution 12 bit (16 bit representation including sign)
Power Supply Via the E-bus
Current Consumption (E-bus) Typical 130 mA
Internal Resistance Greater than 130 kOhm
Input Filter Limit Frequency 1 kHz
Dielectric Strength Max. 30 V
Conversion Time 1.25 ms (default setting, configurable, multiplexed)
Measuring Error Less than +/-0.3% (relative to full scale value)
Electrical Isolation 500 V (E-bus / signal voltage)
Process Image Width 32 bytes (inputs)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 70 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Installation Position Variable

Connections and Interfaces

Connection Type Conductor Specifications
Solid Wire Cross-section 0.08 mm² to 2.5 mm² (AWG 28 to 14)
Stranded Wire Cross-section 0.08 mm² to 2.5 mm² (AWG 28 to 14)
Wire with Ferrule 0.14 mm² to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 mm to 9 mm
Actuation Method Screwdriver-actuated spring tension clamp

Installation Guidelines

  • Mounting: Mount on a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking latch engages securely.
  • Side-by-Side Placement: Use the double slot and key connection system to line up adjacent terminals securely.
  • Wiring: Always use an appropriate screwdriver to actuate the spring contacts when inserting solid, stranded, or ferruled conductors. Ensure stripping length matches the 8–9 mm specification to prevent exposed conductors.
  • Environment: The unit is rated IP20. Ensure it is installed in a dust-free and dry control cabinet or enclosure to prevent condensation and environmental contamination.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27
Loading product navigation…

Does the Beckhoff EL3008 support Distributed Clocks (DC)?

No, the EL3008 terminal does not feature Distributed Clocks support. It transmits process data in sync with the EtherCAT cycle.

What is the measuring range and input impedance of the EL3008?

The EL3008 has a signal voltage input range of -10 V to +10 V, with an input internal resistance of greater than 130 kOhm.

What wire sizes are compatible with the connection terminals of the EL3008?

The spring-tension terminal blocks accommodate solid and stranded wires from 0.08 to 2.5 mm² (AWG 28–14) and wires with ferrules from 0.14 to 1.5 mm² (AWG 26–16).

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...