1 von 1

Beckhoff EL3201-0020 EtherCAT Terminal 1-Channel Analog Input Module

Beckhoff EL3201-0020 EtherCAT Terminal 1-Channel Analog Input Module

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: EL3201-0020

  • Herkunftsland:Deutschland

  • Produkttyp: EtherCAT Terminals

  • Zahlung: T/T, Western Union

  • Gewicht: 60g

  • Abmessungen: 12 mm x 100 mm x 68 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Designed for highly accurate temperature measurement in demanding industrial automation applications, the Beckhoff EL3201-0020 is a high-precision 1-channel analog input terminal configured for Resistance Temperature Detectors (RTD). This EtherCAT terminal enables direct connection of sensors utilizing 4-wire connection technology to ensure maximum measurement accuracy by compensating for cable resistance. Each module is factory-calibrated and delivered with a corresponding calibration certificate, making it suitable for applications requiring strict compliance and traceably accurate temperature logs.

The EL3201-0020 processes signals from various RTD sensor types, including Pt and Ni variants, as well as general resistance measurements. Its integration into the EtherCAT system allows for fast, deterministic communication with the central controller, translating process data directly into a 1 x 32-bit RTD process image. Features such as integrated digital filtering and configurable limit value monitoring allow for flexible adaptation to specific process dynamics.

Features

  • Single-channel high-precision analog input for temperature measurement.
  • Supports a wide range of sensor types: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, and direct resistance measurements.
  • True 4-wire connection technology for precise lead wire compensation.
  • 16-bit analog resolution offering exceptional precision of 0.01 degC per digit.
  • Factory-calibrated with a provided calibration certificate.
  • Integrated digital filtering and software-configurable limit value monitoring.
  • Direct power supply via the E-bus communication interface.

Applications

  • Precision climate and test chamber monitoring.
  • Chemical processing and reactor temperature regulation.
  • Food production and thermal processing lines.
  • Calibration laboratories and quality assurance stations.
  • HVAC and building automation monitoring.

Technical Specifications

ManufacturerPart Number / ModelProduct TypeTechnologySignal TypeSensor Types SupportedMeasuring Range (Pt)Measuring Range (Ni)High-Precision Measuring RangeResolutionConversion TimeMeasuring CurrentMeasuring ErrorCalibration CertificateElectrical IsolationCurrent Consumption E-busProcess Image Bit WidthDimensions (W x H x D)WeightOperating TemperatureStorage TemperatureRelative HumidityEMC Immunity / EmissionVibration / Shock ResistanceProtection Rating / Installation Position
Beckhoff
EL3201-0020
EtherCAT Terminal, 1-Channel Analog Input
4-wire connection
Temperature / RTD
Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g., potentiometer 10 Ohm to 1.25 kOhm), KTY sensors
-200 to +850 degC
-60 to +250 degC
-200 to +320 degC
0.01 degC per digit
approx. 24 ms default (4 to 500 ms configurable)
Less than 0.5 mA (load-dependent)
Less than +/-0.1 degC at 40 degC ambient temperature (4-wire, Pt100 sensor, -200 to +320 degC, 50 Hz filter)
Factory-calibrated
500 V (E-bus / signal voltage)
typ. 190 mA
1 x 32 bit RTD input
12 mm x 100 mm x 68 mm
approx. 60 g
0 to +55 degC
-25 to +85 degC
95 %, non-condensing
Conforms to EN 61000-6-2 / EN 61000-6-4
Conforms to EN 60068-2-6 / EN 60068-2-27
IP20 / variable

Installation Guidelines

  • Mounting: Mount horizontally or vertically on a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking slide is securely engaged.
  • Wiring Connection: Use solid, stranded, or ferruled conductors. Insert wires via spring actuation using a standard flathead screwdriver.
  • Shielding & Noise Reduction: Utilize shielded cabling for sensor lines to prevent electromagnetic interference from power and motor cables. Connect the shield directly to the fieldbus terminal earth ground.
  • E-bus Contacts: Ensure the gold-plated E-bus contact surfaces are clean and free of dust before slotting adjacent terminals together.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
Loading product navigation…

What sensor types are compatible with the Beckhoff EL3201-0020?

The EL3201-0020 supports a wide range of sensors including Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, and resistance measurements from 10 Ohm up to 1.25 kOhm.

Why is 4-wire connection technology used in the EL3201-0020?

4-wire connection technology is utilized to provide high-precision measurements by fully compensating for the lead resistance of the sensor cabling, preventing line resistance from introducing measurement errors.

Does the EL3201-0020 terminal come with calibration documentation?

Yes, the EL3201-0020 is a factory-calibrated analog terminal and includes an individual calibration certificate.

What is the measuring error and resolution of this terminal?

It features a resolution of 0.01 degC per digit, with a measuring error of less than +/-0.1 degC at 40 degC ambient temperature using a Pt100 sensor in a 4-wire connection.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...