Product Overview

The EPP1111-0000 (EPP1111-0000) is an industrial-grade EtherCAT P Box designed for the decentralized identification of specific EtherCAT groups within a larger network topology. Encased in a rugged polyamide housing, this machine-mountable I/O block allows system integrators to assign unique identifiers to modular machine sections or hot-swappable tool assemblies.

By enabling automated group recognition directly on the machine frame, the module facilitates flexible topology configurations and rapid tool changes. This capability prevents configuration mismatches in complex assembly cells, material handling systems, and robotic end-effectors, actively reducing commissioning time and dropping unexpected system downtime.

Topology Identification and Functional Design

The EPP1111-0000 operates within the EtherCAT P system framework, utilizing a single cable connection that simultaneously carries high-speed 100 Mbit/s Fast Ethernet data and 24 V DC system power. The physical interface is equipped with two P-coded, shielded M8 screw-type connectors to enforce proper wiring alignment and preserve signal integrity under high electromagnetic stress.

The module serves as a static node identifier that requires zero software or hardware configuration tools during physical installation. Its primary task is reading and transmitting the group ID to the master controller via standard EtherCAT cable over distances up to 100 meters between stations, ensuring reliable deterministic synchronization across expansive production footprints.

Technical Specifications

Parameter Specifications
Model EPP1111-0000
Brand BECKHOFF
Origin Germany
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw-type, P-coded
Core Network Task Identification of any EtherCAT group in the network
Data Transmission Rate 100 Mbit/s (100BASE-TX)
Maximum Station Distance 100 m
Nominal Voltage 24 V DC (-15 % / +20 %)
Distributed Clocks Not utilized
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Weight Approx. 165 g
Operating Temperature -25 to +60 deg C
Storage Temperature -40 to +85 deg C
Environmental Protection IP65 / IP66 / IP67 (Conforms to EN 60529)
Mechanical Resistance Conforms to EN 60068-2-6 (Vibration) / EN 60068-2-27 (Shock)
Compliance Markings CE, UL

Product FAQs

How does the EPP1111-0000 identify separate groups without manual configuration settings?

The module is detected natively by the EtherCAT master during the network boot scan. It transmits a factory-set or hardware-defined position value directly into the master process image, allowing the control software to verify the machine topology layout and map downstream slave devices based on the group ID.

What is the practical benefit of P-coded M8 connectors over standard EtherCAT connectors?

P-coding integrates EtherCAT communication and the 24 V DC power supply lines into a single, compact M8 interface. This layout eliminates the need for separate communication and power cables, reducing field wiring complexity, cutting down material costs, and minimizing connection failure points.

Can this module be mounted directly onto a machine frame without an electrical control cabinet?

Yes. With an IP65, IP66, and IP67 ingress protection rating, the module's polycarbonate/polyamide housing is entirely sealed against dust, oil, and direct water jets. It is designed specifically for direct on-machine mounting in wet, dirty, or space-constrained industrial zones.


Decentralized Installation and Environmental Safety Guide

  • Mechanical Fastening and Alignment: Mount the box module directly to the machine structure using the two integrated 3.5 mm diameter fixing holes. Use standard M3 screws tightened to a maximum torque specification of 0.6 Nm to avoid cracking the polyamide housing. The module supports variable installation positions to accommodate flexible machine routing paths.

  • M8 Connector Torque and Sealing: To guarantee the IP67 protection rating, all connected M8 P-coded plugs must be tightened using an industrial torque wrench set exactly to 0.4 Nm. Leftover or unused M8 ports must be sealed with official, moisture-proof protective caps. Failure to seal empty sockets allows moisture ingress, leading to short circuits and communication timeouts.

  • Cable Routing and Bending Radii: When routing EtherCAT P cables across moving joints or robotic arms, maintain the manufacturer-specified minimum bending radius for high-flex lines. Separate the communication cables from heavy variable frequency drive (VFD) power cables by at least 10 cm to suppress external cross-talk, ensuring uninterrupted 100 Mbit/s transmission speed.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Schwarz
Country of origin
Deutschland
Power source
Gleichstromversorgung

Recently Viewed Products

Technical knowledge

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...

Einachsige Bewegungssteuerung mit CMZ-Servoantrieben einrichten

Dieses Tutorial behandelt die Inbetriebnahme eines einachsigen Servobewegungssystems mit einem CMZ SBD-Antrieb und umfasst die Hardwareeinrichtung, Achsenskalierung, Homing-Konfiguration und die...