1 von 1

Beckhoff IP2002-B518 Fieldbus Box

Beckhoff IP2002-B518 Fieldbus Box

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: IP2002-B518

  • Herkunftsland:Deutschland

  • Produkttyp: Fieldbus Box

  • Zahlung: T/T, Western Union

  • Gewicht: 2000g

  • Abmessungen: 30 mm x 210 mm x 26.5 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Anzahl
Vollständige Details anzeigen

Description

Designed for direct, machine-mount distributed deployment, the Beckhoff IP2002-B518 coordinates high-density localized outputs without the footprint or cost of protective control enclosures. This decentralized fieldbus box integrates 8 digital outputs operating at 24 V DC, utilizing CANopen protocol communications to optimize real-time control architectures. With integrated M12 T-junction connectors, this device enables clean line-topology bus configurations directly on physical machine frames. Wrapped in a ruggedized polyamide housing, it delivers reliable IP67 protection against moisture, dust, and continuous industrial vibrations.

Features

  • 8 Digital Outputs: Delivers up to 0.5 A per channel, fully compatible with resistive, inductive, and lamp load setups.
  • Integrated T-Connector: Built-in M12 5-pin male and female connectors enable straightforward physical looping of the CANopen bus.
  • Short-Circuit Diagnostics: Individual output channels feature electronic short-circuit protection to insulate localized faults.
  • Flexible Power Distribution: Dedicated M8 connections isolate control logic power (Us) from physical load power (Up).
  • Aggressive Environmental Rating: Rated for IP65/66/67 operation, securing signal paths in high-spray washdown zones.

Applications

  • Pneumatic Valve Block Control: Direct switching of manifold pilot valves on moving gantry assemblies.
  • Material Handling Conveyors: Localized routing of sorting diverters, stop gates, and indicator lights.
  • Automotive Assembly Tooling: Robotic end-effector output distribution where control enclosure space is non-existent.
  • Packaging and Bottling Machinery: Multi-station actuator triggering in high-moisture production zones.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Beckhoff
Model Number IP2002-B518
Module Type 8-Channel Digital Output Fieldbus Box
Protocol / Interface CANopen (16 Tx / 16 Rx PDOs supported)
Supported Baud Rates 10 kbaud to 1 Mbaud (automatic detection)
Number of Outputs 8 (single-wire connection)
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 0.5 A per channel (individually short-circuit proof)
Electrical Isolation 500 V (Control voltage to fieldbus)
Control Voltage Supply (Us) 24 V DC, typical 45 mA current consumption
Fieldbus Connection 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (Integrated T-Connector)
Power Supply Feed 1 x M8 male (4-pin); Downstream loop: 1 x M8 female (4-pin)
Housing Material Polyamide PA6 (XXL housing)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector / Interface Pin Number Signal Assignment
CANopen Fieldbus (M12) Pin 1 CAN_SHLD (Shield)
Pin 2 V+ (Optional External Power)
Pin 3 CAN_GND (Ground)
Pin 4 CAN_H (Signal High)
Pin 5 CAN_L (Signal Low)
Power Supply Feed (M8) Pin 1 Us +24 V DC (Control Voltage for Electronics)
Pin 2 Up +24 V DC (Load Voltage for Digital Outputs)
Pin 3 GNDs (Control Ground)
Pin 4 GNDp (Load Ground)

Empirical Engineering Insights

Alternative Models & Compatibility

The B518 variant serves as an drop-in optimization over legacy B510 fieldbus boxes. Because the IP2002-B518 integrates the T-connector directly within its molded housing, it completely replaces the requirement for external "Z1001" network splitter adapters, decreasing field cabling clutter and potential points of ingress failure.

Application Pitfalls & Engineering Notes

While each individual channel features short-circuit current protection peaking at approximately 1.5 A under fault conditions, the cumulative load across all 8 output channels must not exceed the maximum current rating of the feeding M8 terminal (typically capped at 4 A total across Up). Ensure appropriate current-budget configurations are calculated for simultaneously active inductive loads.

Commissioning & Wiring Tips

To access the decimal rotary node-ID configuration switches, remove the protective cover plate using a small flat screwdriver. Ensure this plate is re-seated with its sealing gasket completely flush to preserve the IP67 integrity. Additionally, note that this module does not integrate internal CAN termination resistors; a physical M12 termination plug must be added at the terminal physical drop-point of the network.

Installation Guidelines

CRITICAL WARNING: Ensure all power distribution lines (Us and Up) are fully de-energized prior to connecting or disconnecting any M8 or M12 cables. Connecting active power lines to IP-series modules can result in contact-arc damage and compromise internal diagnostic logic.
1
Mechanical Mounting: Mount the module directly onto a flat machinery support structure using the two 3.5 mm diameter fixing points using M3 screws. Ensure no torsional stress is applied to the PA6 housing.
2
Configure Node ID: Unscrew the protective cover. Using a rotary switch tool, set the correct CANopen Node ID. Verify the baud rate setting is configured correctly (defaulting to auto-detection). Re-seal the cover.
3
Bus & I/O Connections: Connect the M12 fieldbus lines to the integrated T-connector ports. Tighten the knurled metal collars hand-tight (0.6 Nm torque recommended) to guarantee environmental protection.
4
Power Integration: Hook up the incoming 4-pin M8 feed. If multiple boxes are in line, loop from the downstream M8 female connector to the subsequent device.
Loading product navigation…

What is the function of the integrated T-connector on the IP2002-B518?

The integrated T-connector consists of an M12 plug and an M12 socket, allowing the CANopen fieldbus cable to loop through the module directly. This eliminates the need for separate external T-splitters on the line.

Are the control and load voltages electrically isolated?

Yes, there is 500 V electrical isolation between the control voltage electronics (Us) and the CANopen fieldbus network, reducing the risk of ground loops and signal interference.

How do you set the CANopen node address on this module?

The address is set manually using two decimal rotary switches located under a protective screw-retained cover plate on the front of the polyamide housing.

What happens if a single digital output channel is short-circuited?

Each of the 8 digital outputs is individually short-circuit proof. If a fault occurs, the module limits the current to typically 1.5 A and isolates the fault locally without shutting down the entire block.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) eingehen.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabebedingungen lesen Sie bitte unsere offiziellen Rückerstattungs- & Rückgaberecht .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Die boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...