Description

330881-16-08-095-06-02: PROXPAC XL Proximity Transducer, Metric configuration with a 3300 XL 8 mm probe without approvals, an 80 mm standoff adapter, a 95 mm probe penetration, a specialized 3/4-14 NPT fitting with SST reducer, and a 3/4-14 NPT outer sleeve mounting thread.

This integrated assembly brings the 3300 XL 8 mm probe and Proximitor sensor into a unified, self-contained unit, eliminating the need for an external extension cable and reducing overall field wiring complexity. Unlike variants that omit probe sensors or feature North American/European multi-approvals, this specific transducer includes a 3300 XL 8 mm probe (Option 16) with standard non-approved ratings, combined with a robust Polyphenylene Sulfide (PPS) thermoplastic housing for Type 4X and IP66 severe environment protection.

Features

  • Integrated 3300 XL 8 mm proximity probe (Option 16) with standard non-approved rating.
  • Pre-installed 80 mm metric standoff adapter (Option 08) for specialized mounting offsets.
  • Sleeve penetration length of 95 mm (Option 095) for deep machine casing access.
  • Premium fittings kit featuring one 3/4-14 NPT fitting, one 3/4-14 NPT to 1/2-14 NPT SST reducer, and two plugs (Option 06).
  • Outer sleeve mounting with 3/4-14 NPT threads (Option 02) to secure the standoff adapter assembly.
  • Advanced PPS thermoplastic housing incorporating glass and conductive fibers to dissipate electrostatic charges.

Applications

  • Radial vibration and axial position measurements on rotating machinery.
  • Fluid-film bearing monitoring in severe industrial environments.
  • Heavy-duty machinery protection where separate Proximitor sensor cabinets are impractical.

Ordering Information

Option / Segment Code on This SKU Meaning / Description
Orderable Part Number 330881-16-08-095-06-02 PROXPAC XL Proximity Transducer (Metric)
A - Probe and Approvals Option 16 3300 XL 8 mm probe without approvals
B - Standoff Adapter Option 08 80 mm standoff adapter (B dimension)
C - Probe Penetration Option 095 95 mm probe penetration (C dimension)
D - Fittings Option 06 One 3/4-14 NPT fitting, one 3/4-14 NPT to 1/2-14 NPT SST reducer, and two plugs
E - Mounting Thread Option 02 3/4-14 NPT (required for Standoff Adapter Option)

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number 330881-16-08-095-06-02
Product Series PROXPAC XL
Sensor Input 3300 XL 8 mm Proximity Probe with a 1-meter cable length pre-installed in the probe sleeve
Power Requirements -17.5 Vdc to -26 Vdc at 12 mA maximum without barriers
Linear Range 2.0 mm (80 mils)
Scale Factor 7.87 V/mm (200 mV/mil) nominal
Frequency Response 0 to 10 kHz: +0, -3 dB with up to 305 meters (1000 feet) of field wiring
Housing Material Glass-reinforced and conductive fiber-reinforced Polyphenylene Sulfide (PPS) thermoplastic (UV resistant)
Sleeve & Retaining Chain Material AISI 304 Stainless Steel
Outer Sleeve and Retaining Screws AISI 303 Stainless Steel
O-Ring Material Neoprene (sleeve O-ring), Viton (internal probe seal)
Operating Temperature (Probe) -52 degC to +177 degC (-62 degF to +351 degF)
Operating Temperature (Housing/Sensor) -52 degC to +100 degC (-62 degF to +212 degF)
Storage Temperature -52 degC to +105 degC (-62 degF to +221 degF)
Environmental Rating Type 4X and IP66 (verified by BASEEFA)
Relative Humidity 100% condensing, non-submersible when connectors are protected
Torque Limits Retaining Nut: 29.5 N-m (260 in-lb); Probe Sleeve Locknut: 39.3 N-m (350 in-lb)

Installation Guidelines

  • Environmental Sealing: Ensure all field wiring conduit entries are properly sealed. While the PPS housing is rated for IP66 and Type 4X, moisture must be prevented from migrating through conduit paths.
  • Standoff Alignment: Secure the 3/4-14 NPT outer sleeve threads (Option 02) tightly to lock the 80 mm standoff adapter in place before fine-tuning probe position.
  • Probe Air Gap Adjustment: Adjust the probe sleeve gap with the machine shaft static. Standard linear range center is ideally located at a voltage reading corresponding to the target calibration.
  • Torque Limits: Never exceed 29.5 N-m (260 in-lb) on the housing retaining nut or 39.3 N-m (350 in-lb) on the probe sleeve locknut to prevent damage to the composite housing.

Compliance and Certifications

  • CE Mark: Complies with European Community Directives
  • EMC Directive: EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for industrial environments
  • RoHS Directive: 2011/65/EU compliance
  • Mechanical Protection: IP66 housing rating verified by BASEEFA

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330881-16-08-095-06-02 PROXPAC XL Proximity Transducer

What does option 16 represent for this PROXPAC XL assembly?

Option 16 indicates that this unit is configured with an integrated 3300 XL 8 mm proximity probe and standard, non-approved sensor options.

What is the purpose of the 80 mm standoff adapter and 95 mm penetration?

The 80 mm standoff (Option 08) offsets the probe housing from the machine case, while the 95 mm penetration (Option 095) allows the probe sleeve to properly access the target shaft.

What fitting option is provided with this specific transducer configuration?

This configuration comes with Option 06, which includes one 3/4-14 NPT fitting, one 3/4-14 NPT to 1/2-14 NPT stainless steel reducer, and two blanking plugs.

Can this transducer be used in severe outdoor environments?

Yes. The housing is molded from glass-reinforced polyphenylene sulfide (PPS) and is rated for Type 4X and IP66 environments, providing excellent resistance to severe conditions and electrostatic charges.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails sehen Sie bitte unsere offiziellen Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere fortgeschrittene Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Backen hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...