1 von 1

EPI2008-0001 BECKHOFF IO-Link Box 8-channel Digital Output

EPI2008-0001 BECKHOFF IO-Link Box 8-channel Digital Output

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPI2008-0001

  • Country of origin:Deutschland

  • Product Type: IO-Link box

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Anzahl
Vollständige Details anzeigen

Product Overview

The EPI2008-0001 (EPI2008-0001) is a high-performance industrial IO-Link box from Beckhoff, designed to bridge the gap between field-level sensors/actuators and higher-level control systems. This 8-channel digital output module is engineered for decentralized automation, allowing for the direct connection of actuators in rugged environments without the need for a protective control cabinet. By utilizing the IO-Link V1.1 (Class B) protocol, the EPI2008-0001 ensures high-speed data transfer rates of 230.4 kbaud (COM 3) and provides extensive diagnostic capabilities. Its robust IP67-rated construction makes it an ideal solution for material handling, automotive assembly lines, and food processing plants where resistance to moisture, vibration, and dust is a mechanical necessity for reducing system downtime and simplifying field wiring.

Technical Configuration

The EPI2008-0001 features a modular and compact design optimized for direct machine mounting. It is equipped with one A-coded M12 plug for IO-Link communication and power supply, and eight M8 screw-type connectors for output signals. The "Class B" specification indicates that the module provides additional power supply lines (P24) for the connected actuators, which are electrically isolated from the logic power (L+). Each of the 8 channels supports a nominal output current of 0.5 A and is individually short-circuit proof, ensuring that a fault in one actuator does not compromise the entire module. The internal logic consumes a typical 100 mA from the L+ line, while the auxiliary power line handles the load current, making it a reliable choice for high-density I/O configurations in demanding EMC environments.

Technical Specifications

Feature Specification Details
Model EPI2008-0001
Brand BECKHOFF
Communication IO-Link V1.1, Class B
Data Transfer Rate 230.4 kbaud (COM 3)
Number of Outputs 8 Digital Outputs
Connection (IO-Link) 1 x M12 plug, A-coded
Connection (Output) M8, screw type
Nominal Voltage 24 V DC (-15 percent / +20 percent)
Max. Output Current 0.5 A per channel
Protection Rating IP65 / IP66 / IP67
Operating Temp -25 to +60 Celsius
Weight approx. 165 g

Technical FAQs

What are the diagnostic advantages of using the IO-Link V1.1 interface?

The EPI2008-0001 provides real-time status data via the IO-Link master. This includes channel-specific short-circuit detection and supply voltage monitoring. These parameters can be read by the PLC to trigger predictive maintenance alerts before a total system failure occurs.

Does the "Class B" port mean I need a special IO-Link master?

Yes, to utilize the full capability of the EPI2008-0001, it should be connected to an IO-Link Master Class B port. This ensures the isolated 24 V auxiliary power (P24) is correctly supplied to the actuators via the additional pins in the M12 connection.

Can this module be mounted in any orientation?

The module is designed for a "variable" installation position. Its high vibration resistance (EN 60068-2-6) and shock resistance (EN 60068-2-27) ensure that performance remains consistent whether it is mounted horizontally on a conveyor frame or vertically on a robotic arm.


Engineering & Installation Guide

Power Supply Separation and Safety:

The EPI2008-0001 maintains electrical isolation between the control electronics (L+) and the auxiliary power for outputs (P24). When wiring your IO-Link master, ensure that both power circuits are correctly fused. In safety-critical applications, the P24 supply can be switched off externally via a safety relay to bring all 8 outputs to a "Safe State" without losing IO-Link communication and diagnostic data.

M8 Connector Torque and Sealing:

To maintain the IP67 protection rating, all M8 screw-type connectors must be tightened to the manufacturer's specified torque (typically 0.4 Nm). Any unused ports must be sealed with professional-grade M8 protective caps. Failure to seal unused ports will lead to moisture ingress, which can cause internal short circuits and permanent damage to the logic board.

EMC and Grounding Best Practices:

While the module conforms to EN 61000-6-2/4 for EMC immunity, it is critical to ground the mounting surface if it is metal. If mounting on non-conductive surfaces, ensure the functional earth (FE) is connected via the provided mounting holes to a central grounding point to divert high-frequency interference away from the IO-Link communication line.

 

Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Schwarz
Country of origin
Deutschland
Power source
Gleichstromversorgung

Recently Viewed Products

Technical knowledge

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...

Einachsige Bewegungssteuerung mit CMZ-Servoantrieben einrichten

Dieses Tutorial behandelt die Inbetriebnahme eines einachsigen Servobewegungssystems mit einem CMZ SBD-Antrieb und umfasst die Hardwareeinrichtung, Achsenskalierung, Homing-Konfiguration und die...