1 von 3

GE Multilin UR-8LV UR Series CT/VT Module

GE Multilin UR-8LV UR Series CT/VT Module

Only 7 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-8LV

  • Country of origin:Kanada

  • Product Type: CT/VT Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 177,0 mm x 482,6 mm x 234,0 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Anzahl
Vollständige Details anzeigen

Description

The GE Multilin UR-8LV operates as a high-reliability analog instrumentation component within the Universal Relay (UR) protection and control platform. Designed specifically as a replacement card for vertical hardware frames, this CT/VT Module handles precision simultaneous acquisition of both current and voltage metrics from major power system lines. The hardware is defined by a Standard 4CT/4VT with enhanced diagnostics layout, integrating four current transformer (CT) channels and four voltage transformer (VT) channels onto a unified circuit assembly. This enables the parent relay to continuously analyze three-phase power variables plus an additional auxiliary channel for neutral or zero-sequence parameter tracking. Engineered to cooperate directly with an enhanced front panel with Chinese display and user-programmable pushbuttons, the UR-8LV feeds vital electrical network samples to the CPU for localized protection logic execution, comprehensive power metering, true RMS evaluation, and active waveform event monitoring in regions utilizing Chinese-localized interface architectures.

Features

  • Integrates a balanced 4CT (Current Transformer) and 4VT (Voltage Transformer) channel design within a single, full-height slot footprint.
  • Implements enhanced internal hardware diagnostics to continuously verify signal cross-checks and analog-to-digital converter path health.
  • Built to interface seamlessly with specialized UR front-panel variants featuring native Chinese character displays.
  • Supports high-fidelity continuous sampling of alternating current and AC voltage waveforms for localized relay intelligence.
  • Equipped with mechanical internal CT shorting bars that lock closed automatically to secure field loops upon card extraction.
  • Manufactured specifically to comply with the alignment tracks of vertical orientation rack configurations.

Applications

  • Three-phase feeder protection paired with zero-sequence or residual voltage/current monitoring.
  • Main-tie-main and bus-coupler protective relaying in localized industrial sub-distribution plants.
  • Substation automation nodes requiring localized Chinese text interfaces and manual command pushbuttons.
  • Core instrumentation tracking for multi-zone voltage stability and overcurrent coordination.

Ordering Information

Code / Option Component Functional Description
UR-8LV Main Replacement Assembly Number for Vertical Units
UR UR Series Industrial Protection Platform
8L Standard 4CT/4VT Input Combination with Enhanced Hardware Diagnostics
V Interfacing Variant: Enhanced Front Panel with Chinese Display and User-Programmable Pushbuttons

Technical Specifications

Parameter Category Specification Details
Manufacturer GE Multilin (General Electric)
Country of Origin Canada
Module Type CT/VT Analog Input Module
Mechanical Layout Vertical chassis configuration compatibility
Channel Capacity 4 Current Inputs (4CT) + 4 Voltage Inputs (4VT)
Diagnostic Layer Continuous enhanced self-testing analog path monitoring
Dimensions Standard full-height UR Series plug-in card profile
Weight Omitted (module-level physical weight not listed in source documentation)

Connections/Interfaces

The rear terminal terminal map of the UR Series relies on a coordinate-based indexing scheme corresponding directly to the slot position where the UR-8LV card is installed.

  • CT Terminal Blocks: Rigid heavy-duty barrier terminals integrated with automatic, physical spring-loaded shorting bars to handle continuous current feedback.
  • VT Terminal Blocks: High-dielectric isolation voltage ports dedicated to receiving secondary potential utility instrumentation lines.

Installation Guidelines

  • De-energization Rule: Ensure that all primary control power supplied to the UR chassis is fully isolated and switched off before sliding out or inserting any sub-assembly.
  • ESD Mitigation: Technicians must wear a grounded anti-static wrist strap throughout the installation or maintenance cycle to prevent static discharges into the microprocessors.
  • Card Insertion: Slide the card evenly into the physical track of the vertical rack slot until the inner backplane connectors engage, then lock the upper and lower faceplate latch mechanisms simultaneously to ensure a uniform connection.
  • Display Verification: Following system power-up, cross-check the front-panel localized display module to ensure that the newly updated analog channel arrays align correctly with the localized menu logic.
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin UR-8LV UR Series CT/VT Module

正在加载 PDF,请稍候…

Welche Konfiguration von analogen Eingängen bietet die UR-8LV-Hardware?

Das Modul enthält eine Standard-4CT- und 4VT-Konfiguration und bietet vier Stromwandler-Eingangskanäle sowie vier Spannungswandler-Eingangskanäle mit erweiterten Onboard-Diagnosen.

Kann diese Karte in einer horizontalen UR-Relais-Chassis-Konfiguration verwendet werden?

Nein. Die Bestellcodestruktur weist diese Modulversion ausdrücklich als Ersatz für vertikale Einheiten und vertikale Rackrahmen aus.

Was bedeutet die 'V'-Suffixbezeichnung bei diesem Modul?

Die Bezeichnung 'V' zeigt an, dass die Karte für die direkte Schnittstelle mit der erweiterten Frontplattenbaugruppe mit chinesischer Textanzeige und benutzerprogrammierbaren Tasten ausgelegt ist.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Schwarz
Country of origin
Kanada

Recently Viewed Products

Technical knowledge

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...

Einachsige Bewegungssteuerung mit CMZ-Servoantrieben einrichten

Dieses Tutorial behandelt die Inbetriebnahme eines einachsigen Servobewegungssystems mit einem CMZ SBD-Antrieb und umfasst die Hardwareeinrichtung, Achsenskalierung, Homing-Konfiguration und die...