1 von 1

Omron NS5-TQ10B-ECV2 NS-Series Programmable Terminal

Omron NS5-TQ10B-ECV2 NS-Series Programmable Terminal

Nur noch 5 Artikel auf Lager verfügbar
  • Hersteller: Omron

  • Produkt-Nr.: NS5-TQ10B-ECV2

  • Herkunftsland:Japan

  • Produkttyp: HMI Operator Terminals

  • Zahlung: T/T, Western Union

  • Gewicht: 8000g

  • Abmessungen: 245 x 195 x 110 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Engineered for distributed machine-level monitoring, the Omron NS5-TQ10B-ECV2 serves as a centralized operator control interface within the premium NS-Series platform. This hardware terminal combines a vibrant 5.7-inch High-Luminance TFT Color LCD with robust communication capabilities, incorporating an integrated 10Base-T Ethernet port and dual serial transceivers. Operating on a standard 24 VDC input, the terminal is designed to withstand harsh factory environments, featuring an IP65f front-face rating and a resilient black protective bezel. With 60 MB of internal memory, it supports complex graphic representations, high-density alarm logging, and seamless CX-Designer configuration integration.

Features

  • High-visibility TFT display supporting up to 32,768 colors for realistic CAD-based machine graphics.
  • Built-in Ethernet port enabling FTP server capabilities, data transfers, and remote monitoring over TCP/IP.
  • Dual independent RS-232C serial ports for direct, simultaneous connections to PLCs, temperature controllers, and barcode readers.
  • Extensive 60 MB memory allocation for substantial screen data storage, system recipes, and historic trend logs.
  • High-durability LED backlight providing long-term illumination consistency without the degradation risks of legacy CCFL lamps.

Applications

  • Automated packaging and cartoning machinery line integration.
  • Pumping stations and local water treatment HMI monitoring panels.
  • Automotive component assembly verification and testing cells.
  • Discrete material handling and sorting system visualization.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron
Model Number NS5-TQ10B-ECV2
Display Type 5.7-inch High-Luminance TFT Color LCD
Resolution 320 x 240 pixels (QVGA)
Backlight LED (non-replaceable, service life approx. 50,000 hours)
Input Voltage 24 VDC (Acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 W maximum
Onboard Ethernet 1x RJ-45 Port (10Base-T)
Serial Communications 2x RS-232C Ports (D-sub 9-pin female)
USB Interfaces 1x USB Type B Slave (for programming download)
Internal Project Memory 60 MB Flash Memory
Enclosure Bezel Color Black
Protection Rating IP65f (front panel, panel-mounted)
Operating Temperature 0 to 50 degC
Shipping Weight (Calculated) 1.85 kg
Package Dimensions (Calculated) 245 x 195 x 110 mm

Connections and Interfaces

Port / Terminal Block Physical Form Signal Assignment & Pin Function
Serial Port A (CN1) D-sub 9-pin Female Host Link / NT Link RS-232C communication channel 1
Serial Port B (CN2) D-sub 9-pin Female Host Link / NT Link RS-232C communication channel 2
Ethernet RJ-45 10Base-T network interface (FTP, screen data transfer, FINS communications)
USB (Slave) USB Type B Connection to CX-Designer programming PC for screen development and diagnostics
Power Input M3 Screw Terminals Pin 1: +24 VDC | Pin 2: 0 VDC | Pin 3: Functional Ground (FG)

Empirical Engineering Insights

Alternative Models & Compatibility

The "ECV2" revision represents a major evolutionary step over older NS5-TQ10B-V2 units. The critical distinction lies in the backlight design: the ECV2 employs an integrated solid-state LED configuration, whereas earlier legacy units utilized CCFL tubes driven by high-voltage internal inverters. Project databases generated for older NS5 versions can be converted to run on the ECV2 unit via CX-Designer; simply update the destination hardware designation inside the system properties before transferring. Be aware that color rendering profiles may differ slightly due to the shift from CCFL to LED emission spectrums.

Application Pitfalls & Engineering Notes

Touch-screen matrix degradation is a common physical failure point if these terminals are installed in close proximity to radiant heat sources. While the unit functions up to 50 degC, prolonged internal temperatures exceeding 45 degC inside non-ventilated enclosures can lead to local delamination of the resistive overlay. For panels where ambient internal heat is a constant factor, we recommend installing low-draw convective air systems or cooling fans, maintaining a mandatory 100 mm clearing around the backplate air vents.

Commissioning & Wiring Tips

To prevent grounding-loop failures across serial pathways, ensure the functional ground terminal (FG) is tied back to the main cabinet star-ground point via a heavy-gauge (minimum 2 mm²) stranded green wire. When implementing RS-232C communication lines to CS/CJ-series PLCs, always utilize double-shielded twisted pairs and ground the cable shield on the PLC chassis side only. This layout successfully diverts high-frequency industrial noise away from the NS5 transceiver chips, avoiding intermittent "HMI Communication Timeouts" errors.

Installation Guidelines

CRITICAL WARNING: Isolate the 24 VDC supply and de-energize the entire control panel prior to attempting HMI physical mounting or electrical termination. Executing wiring procedures while power is active can induce voltage spikes, causing permanent logic board destruction.
1
Ensure the panel cutout dimensions measure exactly 184.0 mm (+0.5/-0 mm) wide by 131.0 mm (+0.5/-0 mm) high to achieve an optimal environmental seal.
2
Check that the waterproof rubber sealing gasket is seated uniformly in the front-bezel groove before inserting the HMI terminal into the cutout.
3
Secure the unit into the panel using the provided metal mounting clamps. Tighten the clamping screws evenly to a target torque of 0.5 to 0.6 N-m; over-torqueing may warp the plastic bezel, ruining the IP65f seal.
4
Terminate the 24 VDC lines to the power terminal block, verifying polarity matches the marked terminals before switching on the power.
Loading product navigation…

What is the primary technical difference between the ECV2 and the standard V2 NS5 models?

The ECV2 model incorporates an integrated LED backlight and built-in 10Base-T Ethernet, replacing the CCFL backlights used in standard V2 units, which reduces thermal output and increases operational lifespan.

Does this operator terminal support expansion communication boards?

Yes, the NS5 features a backplate expansion slot that allows the installation of Controller Link or other option boards to integrate with existing network architectures.

Can I download projects to the NS5 terminal without using the USB port?

Yes, screen projects can be transferred directly over the network using the built-in Ethernet interface, or physically using a standard Memory Card in the integrated slot.

What software package is required to configure the screen graphics for this HMI?

Omron CX-Designer, which is part of the comprehensive CX-One software suite, is the native utility used to configure and program the NS-Series terminals.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...