1 von 1

ProSoft PLX31-PND-MBS4 PROFINET Device to Modbus Serial Gateway

ProSoft PLX31-PND-MBS4 PROFINET Device to Modbus Serial Gateway

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: ProSoft

  • Produkt-Nr.: PLX31-PND-MBS4

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Industrial Communication Gateways

  • Zahlung: T/T, Western Union

  • Gewicht: 1500g

  • Abmessungen: 13.67 x 5.05 x 11.13 cm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Anzahl
Vollständige Details anzeigen

Description

Interfacing high-speed Ethernet-based PROFINET networks with legacy serial field devices is managed efficiently by the ProSoft PLX31-PND-MBS4, a specialized four-port communication gateway. This hardware facilitates bidirectional data exchange between controllers on a PROFINET network and Modbus serial devices. Featuring four independent, fully isolated serial ports, the gateway acts as a PROFINET Class A Device, supporting substantial data transfer volumes of up to 1440 bytes input and 1440 bytes output. Its robust, DIN-rail-mountable industrial enclosure and wide temperature rating make it suitable for continuous service in harsh control environments.

Features

  • Four Active Serial Ports: Each port is independently configurable to support Modbus RTU or Modbus ASCII protocol architectures.
  • Flexible Mode Settings: Supports Modbus Master or Modbus Slave operational modes per port, enabling simultaneous polling of sensors and serving data to multiple hosts.
  • High Data Throughput: Handles up to 1440 bytes of cyclic input data and 1440 bytes of cyclic output data for large-scale telemetry acquisition.
  • Acyclic Data Integration: Supports both Cyclic Real-time (RT) and Acyclic Data exchanges to pass diagnostic and acyclic parameters smoothly.
  • Electrical Isolation: Integrated Ethernet port features 1500 Vrms isolation to protect the internal processing logic from electrical surges and ground loops.
  • Broadcast Storm Resiliency: Hardened against industrial network traffic issues with dynamic broadcast storm limits of up to 5000 ARP frames-per-second.

Applications

  • Substation Telemetry: Connecting Modbus-based power quality analyzers, multifunction meters, and protection relays to a central PROFINET PLC.
  • Process Skid Integration: Linking legacy Modbus-enabled flow computers, valve manifolds, and temperature controllers to modern DCS platforms.
  • Infrastructure Monitoring: Interfacing remote pump controllers, gas detection systems, and variable frequency drives over serial lines into municipal water or oil and gas control networks.

Technical Specifications

Parameter Value / Specification
Manufacturer ProSoft Technology
Model Reference PLX31-PND-MBS4
PROFINET I/O Capacity 1440 bytes Input, 1440 bytes Output
PROFINET Driver Type Class A Device
Number of Serial Ports 4 isolated ports
Modbus Command Lists Up to 100 commands per Master port (configurable Function Codes)
Nominal Supply Voltage 24 VDC (10 to 36 VDC permitted limits)
Current Consumption 300 mA at 24 VDC nominal (610 mA maximum)
Operating Temperature -25 degC to 70 degC (-13 degF to 158 degF)
Storage Temperature -40 degC to 80 degC (-40 degF to 176 degF)
Relative Humidity 5% to 95% non-condensing RH
Ethernet Isolation 1500 Vrms, 50 to 60 Hz for 60 seconds (IEC 60950)
Mechanical Dimensions 13.67 x 5.05 x 11.13 cm (H x W x D)
Shipping Weight 1.50 kg

Connections and Interfaces

Port / Terminal Connector Type Signal Assignment
Ethernet Port RJ45 PROFINET Network / Config; 10/100 Mbps Base-TX
Serial Ports 1 - 4 DB9 Male (with terminal adapters) RS-232, RS-422, or RS-485 configurable modes
Power Input 3-Pin J180 Screw Terminal Block Positive (V+), Negative (V-), Protective Ground (GND)

Empirical Engineering Insights

Alternative Models & Compatibility

This unit replaces older multi-gateway systems that required separate PROFINET to Modbus RTU interface modules. By combining four distinct serial ports onto a single IP address, it decreases PROFINET node counts and simplifies PLC hardware configurations. Note that older configuration files from single-port models must have their register mappings offset properly to utilize the 4-port memory structure without overlap.

Application Pitfalls & Engineering Notes

A common issue occurs when configuring multiple Modbus Master commands. If a slave device drops offline, the Modbus polling cycle can experience long timeouts, slowing down update speeds across that entire port. Set your Modbus timeouts and retry parameters precisely in ProSoft Configuration Builder (PCB) to prevent slow network refresh rates.

Commissioning & Wiring Tips

When utilizing RS-485 multidrop configurations, remember to terminate the physical bus. Use the provided DB9 to screw terminal adapters to install 120-ohm termination resistors across the TX/RX+ and TX/RX- lines at the end of each physical serial segment. Keep your signal ground reference tied to earth at only one single point to avoid destructive ground-loop noise.

Installation Guidelines

CRITICAL WARNING: Prior to attempting hardware installation, servicing, or terminal wiring, ensure all 24 VDC incoming power sources are completely de-energized. Failure to follow industrial lock-out/tag-out procedures can result in terminal damage, logic lockup, or control network dropouts.
1
Mount the module firmly to a 35mm DIN rail with proper orientation, ensuring adequate air gap clearance around ventilation slots.
2
Connect the protective earth ground wire to the designated grounding terminal, and then connect the 24 VDC power supply using the J180 plug.
3
Insert the CAT5e/CAT6 Ethernet cable into the isolated RJ45 port and wire your serial lines to the serial DB9 connectors using shielded cabling.
4
Power up the system, launch ProSoft Configuration Builder to define your network settings, and assign register tables for your PROFINET master controller.
Loading product navigation…

What is the maximum cyclic data payload capacity supported by the PLX31-PND-MBS4?

This gateway supports up to 1440 bytes of input data and 1440 bytes of output data for cyclic real-time (RT) data exchanges as a PROFINET Class A device.

Can I configure each of the four serial ports independently?

Yes. Each serial port operates independently and can be configured as either a Modbus RTU/ASCII Master or Slave, complete with custom baud rates, timeouts, and command tables.

What are the power requirements for this gateway?

The gateway operates on a nominal 24 VDC power supply, but tolerates input voltages between 10 and 36 VDC. Typical current consumption is 300 mA at 24 VDC.

Does this module support both RS-232 and RS-485 serial communication?

Yes. All four serial ports can be individually wired to support RS-232, RS-422, or 2-wire/4-wire RS-485 communication interfaces.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) eingehen.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabebedingungen lesen Sie bitte unsere offiziellen Rückerstattungs- & Rückgaberecht .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Die boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...