1 von 1

Siemens 6AV7615-0AF10-0AH0 SIMATIC Panel PC 670 Panel PC

Siemens 6AV7615-0AF10-0AH0 SIMATIC Panel PC 670 Panel PC

Only 5 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AF10-0AH0

  • Country of origin:Deutschland

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 48 x 38 x 18 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Anzahl
Vollständige Details anzeigen

Description

The Siemens 6AV7615-0AF10-0AH0 is a SIMATIC Panel PC 670, an integrated operator panel designed for industrial human-machine interface (HMI) and control applications. This unit is equipped with a 15-inch TFT display and is powered by a 300 MHz Celeron CPU. The standard configuration includes 64 MB of RAM, a 40 GB hard drive, and an integrated CD-ROM drive. It operates on a nominal 24 V DC power supply and is pre-installed with a German language version of Windows NT 4.0. As an obsolete product, this panel PC serves as a direct replacement for existing systems to maintain operational continuity.

Features

  • 15-inch TFT color display for process visualization.
  • Intel Celeron processor operating at 300 MHz.
  • Equipped with 64 MB of system RAM.
  • Includes a 40 GB hard disk drive and a CD-ROM drive.
  • Operates on a standard 24 V DC industrial power supply.
  • Pre-loaded with Windows NT 4.0 (German) operating system.

Applications

  • Machine-level operator control and monitoring.
  • Process visualization in manufacturing and production lines.
  • Data acquisition and logging systems.
  • Supervisory control in small to medium-sized applications.
  • Replacement unit for legacy SIMATIC PC-based HMI systems.

Technical Specifications

Specification Value
Brand Siemens
Model Number 6AV7615-0AF10-0AH0
Product Series SIMATIC Panel PC 670
Product Type Panel PC
Display 15-inch TFT
Processor (CPU) Celeron 300 MHz
Memory (RAM) 64 MB
Storage 40 GB Hard Drive
Optical Drive CD-ROM
Power Supply 24 V DC
Operating System Windows NT 4.0 (German)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Manufacturer Siemens AG
Package Dimensions (Calculated) 48 x 38 x 18 cm

Installation Guidelines

CRITICAL WARNING: Electrical hazard. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout/Tagout (LOTO) procedures.
  1. 1 Prepare Mounting Location: Ensure the control cabinet or panel cutout matches the PC670's dimensions. Verify that the mounting surface is clean, flat, and provides adequate structural support for the unit's weight.
  2. 2 Mount the Unit: Carefully insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly in a cross-pattern to ensure a uniform seal against the panel gasket. Do not overtighten.
  3. 3 Connect Protective Earth (PE): Connect the cabinet's protective earth conductor to the designated PE terminal on the Panel PC chassis. This is a critical safety connection and must be established before any other wiring.
  4. 4 Connect DC Power: Connect the 24 V DC power supply to the unit's power input connector, observing correct polarity. Use appropriately sized wiring for the load and ensure the power source is stable and within the specified voltage range.
  5. 5 Connect Peripherals: Connect any required network cables, USB devices, or other communication interfaces. Ensure all connectors are fully seated. Route cables neatly and secure them to prevent strain on the ports.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Recently Viewed Products

Technical knowledge

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...

Einachsige Bewegungssteuerung mit CMZ-Servoantrieben einrichten

Dieses Tutorial behandelt die Inbetriebnahme eines einachsigen Servobewegungssystems mit einem CMZ SBD-Antrieb und umfasst die Hardwareeinrichtung, Achsenskalierung, Homing-Konfiguration und die...