1 von 1

Siemens 6AV7881-4AF00-4DT0 SIMATIC IPC277D Nanopanel PC

Siemens 6AV7881-4AF00-4DT0 SIMATIC IPC277D Nanopanel PC

Nur noch 6 Artikel auf Lager verfügbar
  • Hersteller: Siemens

  • Produkt-Nr.: 6AV7881-4AF00-4DT0

  • Herkunftsland:Deutschland

  • Produkttyp: Panel PC

  • Strichcode: 85371098

  • Zahlung: T/T, Western Union

  • Gewicht: 4550g

  • Abmessungen: 60.50 x 41.50 x 6.50 cm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Anzahl
Vollständige Details anzeigen

Description

The Siemens 6AV7881-4AF00-4DT0 is a SIMATIC IPC277D Nanopanel PC, an integrated human-machine interface (HMI) solution for industrial environments. This unit features a 15-inch touch TFT display, an Intel Atom E660 (1.3 GHz) processor, and 2 GB of RAM for demanding visualization and control tasks. It is equipped with a comprehensive set of interfaces, including dual Gigabit Ethernet ports, multiple USB 2.0 ports, and a serial port, all powered by a standard 24 V DC supply. The system comes pre-loaded with Windows Embedded Standard 7 SP1 and includes licenses for WinCC Advanced RT, providing a ready-to-deploy platform for automation projects.

Features

  • 15-inch color TFT resistive touch display
  • Fanless design with Intel Atom E660 1.3 GHz processor
  • 2 GB of integrated RAM
  • 16 GB CompactFlash card for storage and operating system
  • Pre-installed Windows Embedded Standard 7 SP1 (WES 7 SP1)
  • Includes WinAC RTX F 2010, WinCC Advanced RT V13, and WinCC RT Advanced V14 license package
  • Dual 10/100/1000 Mbps Ethernet interfaces for network connectivity
  • Multiple USB 2.0 ports, including a front-accessible port
  • Operates on a 24 V DC power supply

Applications

  • Machine-level operator control and monitoring
  • Process visualization (SCADA/HMI)
  • Data acquisition and logging
  • Factory and process automation control systems
  • Manufacturing Execution Systems (MES) terminals

Technical Specifications

Specification Value
Product Type Nanopanel PC
Display 15" Touch TFT
Processor Intel Atom E660 (1.3 GHz)
Memory (RAM) 2 GB
Storage 16 GB SIMATIC PC CompactFlash
Operating System Windows Embedded Standard 7 SP1 (WES 7 SP1)
Pre-installed Software WinAC RTX F 2010; WinCC Advanced RT V13 2048 PT; WinCC RT Adv. V14 License Package
Power Supply 24 V DC
Ethernet Ports 2x 10/100/1000 Mbps Ethernet RJ45
USB Ports 1x Front USB; 3x USB V2.0 (High Current)
Serial Port 1x Serial (COM 1)
Expansion Slots 1x CompactFlash Slot
Product Lifecycle Status Phase-Out
Manufacturer Siemens
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 60.50 x 41.50 x 6.50 cm
Shipping Weight 4.55 kg

Installation Guidelines

CRITICAL WARNING: Hazardous voltages may be present. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out/tagged out (LOTO) before commencing any installation, wiring, or maintenance activities. Failure to comply can result in severe injury or death.
  1. 1
    Panel Cutout and Mounting: Prepare the control cabinet panel cutout according to the manufacturer's dimensional drawings. Ensure the mounting surface is clean, flat, and rigid. Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified ingress protection rating.
  2. 2
    Protective Earth (PE) Connection: Connect the chassis to the control cabinet's protective earth system using a low-impedance conductor. Use the designated PE terminal on the Panel PC. This connection is critical for electrical safety and noise immunity.
  3. 3
    Power Supply Wiring: Connect a stable, filtered 24 V DC power source to the designated power supply terminals. Verify correct polarity (+/-) before energizing. Use appropriately sized conductors and ensure the power supply is adequately rated for the PC's current draw.
  4. 4
    Interface Connections: Connect Ethernet, USB, and serial cables as required by the application. Use shielded cables for all data communication lines and ensure shields are properly terminated to ground at one end to minimize electromagnetic interference (EMI). Route data cables separately from high-voltage power lines.
  5. 5
    System Power-Up and Configuration: After verifying all connections, remove the LOTO device and apply power to the unit. The pre-installed operating system will boot. Proceed with network configuration, application software installation, and system commissioning as required.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) eingehen.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabebedingungen lesen Sie bitte unsere offiziellen Rückerstattungs- & Rückgaberecht .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Die boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...