1 von 1

Siemens 6GK5788-2GD00-0TB0 SCALANCE W788-2 M12 EEC IWLAN Access Point

Siemens 6GK5788-2GD00-0TB0 SCALANCE W788-2 M12 EEC IWLAN Access Point

Only 7 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6GK5788-2GD00-0TB0

  • Country of origin:Deutschland

  • Product Type: IWLAN Access Point

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 1800g

  • Dimensions: 27.9 x 25.4 x 17.8 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Anzahl
Vollständige Details anzeigen

Description

This Siemens 6GK5788-2GD00-0TB0 is an industrial wireless LAN (IWLAN) access point from the SCALANCE W788-2 M12 EEC series, specifically configured for operation within the USA. It is engineered for high-performance wireless communication in demanding industrial environments, featuring dual radios that support IEEE 802.11a/b/g/h/n standards and achieve gross data rates of up to 450 Mbit/s per radio. The unit is housed in a rugged IP65-rated enclosure with M12 and N-CON connectors, ensuring reliable operation in environments with dust, water, and vibration. Power can be supplied via Power over Ethernet (PoE) or a redundant 24 V DC input, providing installation flexibility.

Features

  • Dual-radio operation on 2.4 GHz and 5 GHz frequency bands.
  • Supports IEEE 802.11a/b/g/h/n wireless standards.
  • High data throughput with up to 450 Mbit/s per radio.
  • Rugged IP65-rated enclosure with M12 connectors for harsh environments.
  • Wide operating temperature range from -40 to +70 degC.
  • Conformal coating for enhanced protection against humidity and corrosive elements.
  • Flexible power options with Power over Ethernet (PoE) and redundant 24 V DC input.
  • Compliant with EN 50155 and EN 45545 railway standards.
  • Supports advanced iFeatures via an optional KEY-PLUG.

Applications

  • Railway and public transportation systems.
  • Automated Guided Vehicles (AGVs) and mobile equipment.
  • Outdoor industrial networking and infrastructure monitoring.
  • Process automation in manufacturing plants and refineries.
  • Machine-to-machine (M2M) communication in harsh environments.

Technical Specifications

Specification Value
Product Type IWLAN Access Point
Wireless Radios 2
Wireless Standards IEEE 802.11a/b/g/h/n
Frequency Bands 2.4 GHz / 5 GHz
Data Transfer Rate (Gross) Up to 450 Mbit/s per radio
Ethernet Port 1x M12 (A-coded), max. 1 Gbit/s
Antenna Ports 6x N-CON
Power Supply Redundant 24 V DC
Power over Ethernet (PoE) Supported
Security WPA2/802.11i/e
Protection Rating IP65
Operating Temperature -40 to +70 degC
Features Conformal coating, iFeatures support via KEY-PLUG
Compliance EN 50155, EN 45545
Regional Approval For operation in USA only
Country of Origin Germany (Estimate)
Manufacturer Siemens
Shipping Weight 1.80 kg
Package Dimensions (Calculated) 27.9 x 25.4 x 17.8 cm

Installation Guidelines

CRITICAL WARNING: RISK OF EQUIPMENT DAMAGE AND NON-COMPLIANCE

This device is certified for operation within the United States only. Installation or use outside the USA may violate local regulations. Always de-energize all power sources and follow Lockout/Tagout (LOTO) procedures before installation or maintenance to prevent electrical shock.

  1. 1 Verify Site and Approvals: Confirm the installation location is within the USA. Ensure the mounting surface is stable and can support the device's weight (1.80 kg) and any connected antennas and cabling.
  2. 2 De-energize Equipment: Before making any connections, ensure all related power sources (24 V DC and PoE network switches) are de-energized and locked out per established safety protocols.
  3. 3 Mount the Device: Securely fasten the SCALANCE W788-2 unit to the designated mounting surface using appropriate hardware for the environment (e.g., vibration-resistant bolts).
  4. 4 Establish Ground Connection: Connect the device's functional earth/grounding terminal to the main system or cabinet ground using a low-impedance conductor to ensure proper electrical safety and signal integrity.
  5. 5 Connect Antennas: Attach the required antennas to the six N-CON ports. Ensure connections are tightened to the correct torque specification to maintain the IP65 rating.
  6. 6 Connect Ethernet/PoE: Using an industrial-grade M12 A-coded Ethernet cable, connect the device to the network. If using PoE, ensure the switch port provides the required power.
  7. 7 Connect DC Power (If Used): If not using PoE, connect the redundant 24 V DC power supply to the designated M12 power connector, observing correct polarity.
  8. 8 Install Sealing Caps: To maintain the IP65 rating, install the provided M12 and N-CON sealing caps on all unused ports.
  9. 9 Power On and Verify: Remove LOTO devices and apply power to the system. Observe the device's status LEDs to confirm correct startup, network connectivity, and radio operation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Recently Viewed Products

Technical knowledge

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...

Einachsige Bewegungssteuerung mit CMZ-Servoantrieben einrichten

Dieses Tutorial behandelt die Inbetriebnahme eines einachsigen Servobewegungssystems mit einem CMZ SBD-Antrieb und umfasst die Hardwareeinrichtung, Achsenskalierung, Homing-Konfiguration und die...