1 of 1

7AO352.70 B&R 2003 Series Analog Output Module

7AO352.70 B&R 2003 Series Analog Output Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: 7AO352.70

  • Country of origin:ایالات متحده آمریکا

  • Product Type: Analog Output Module

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The 7AO352.70 (7AO352.70) is a high-reliability analog output module from the B&R 2003 Series, engineered to provide precise control signals for industrial actuators, valves, and drive systems. Equipped with 2 independent outputs, this module supports flexible signaling options including +/- 10 V or 0 to 20 mA, catering to a wide range of global industrial standards. With its 12-bit resolution and robust "screw-in" architecture, the 7AO352.70 is specifically designed for long-term stability in demanding sectors such as oil and gas, chemical processing, and power distribution. Its cULus HazLoc certification confirms its suitability for Class I, Division 2 environments, making it a critical component for safe operation in potentially explosive atmospheres where system reliability is non-negotiable.

Technical Configuration

The 7AO352.70 serves as a bridge between digital control logic and analog field devices, converting 12-bit digital values into high-fidelity electrical signals. The module’s architecture is optimized for versatility; users can configure each output to operate in voltage or current mode depending on the requirements of the connected load. As a screw-in module for the B&R 2003 system, it facilitates a secure mechanical connection to the base plate, ensuring electrical contact remains consistent even under significant mechanical vibration. Note that for electrical termination, this module requires the separate acquisition of the TB712 terminal block, which provides the necessary interface for field wiring.

Technical Specifications

Feature Specification Details
Model 7AO352.70
Brand B&R Industrial Automation
Series 2003
Output Type 2 Analog Outputs
Signal Ranges +/- 10 V or 0 to 20 mA
Resolution 12-bit
Hardware Form Screw-in Module
Required Accessory TB712 Terminal Block (Order separately)
Hazardous Location cULus HazLoc Class I, Div 2, Groups ABCD
Compliance CE, UKCA, EAC, cULus
Operating Temp 0 to +55 Celsius (Industry Standard)
Shipping Weight 2.0 kg

Technical FAQs

Is the 7AO352.70 compatible with the TB718 terminal block?

The official technical documentation specifies the TB712 terminal block for this module. Using a different terminal block may lead to improper pin alignment or inadequate electrical contact, potentially voiding certifications or damaging the output stage.

How does the 12-bit resolution translate to signal accuracy?

A 12-bit resolution divides the output range into 4,096 discrete steps. For a +/- 10 V range (20 V total span), this provides a theoretical step size of approximately 4.88 mV, ensuring smooth control for most industrial PID loops and motor speed references.

Can this module be installed while the system is powered?

No. As a screw-in module for the 2003 series, the system power must be completely shut down before installation or removal. Failing to do so can cause electrical arcing or damage to the internal K-bus interface of the controller.


Engineering & Installation Guide

  • Shielding for Precision: Analog signals are highly susceptible to electromagnetic interference. Always use high-quality shielded twisted-pair (STP) cabling for the output lines. The shield should be grounded at a single point, ideally at the control cabinet entry, to prevent ground loops that could introduce offset errors in the +/- 10 V signal.

  • Thermal Management in HazLoc Zones: When operating in Class I, Division 2 environments, ensure that the cabinet’s internal temperature does not exceed 55 Celsius. Excessive heat can accelerate the aging of analog components and potentially affect the T-code rating of the assembly.

  • Terminal Block Torque: When attaching the TB712 terminal block, ensure all screws are tightened to the specified torque. A loose connection on a 0 to 20 mA loop can cause high resistance, leading to signal clipping or "open loop" errors in the controller's diagnostic registers.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
سفید خاکستری
Country of origin
ایالات متحده آمریکا

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...