Product Overview

ICSO 08 R1 (ICSO08R1) is a digital output module for the ABB CS31 distributed I/O system. The module provides 8 electrically isolated relay output channels designed for industrial control applications requiring reliable switching of field devices such as contactors, solenoids, signal lamps, and auxiliary relays.

Each relay output supports up to 2 A switching current and is electrically isolated from the system bus and adjacent channels. The module connects to the CS31 system bus through a plug-in base ECZ and includes integrated diagnostic functions with front-panel LED status indication.

ICSO 08 R1 modules are commonly used in factory automation systems, power plant control panels, water treatment systems, and process automation cabinets where stable relay-based output switching is required.

Technical Configuration

The ICSO 08 R1 combines relay output isolation, diagnostic indication, and CS31 remote I/O communication in a compact DIN rail design.

Feature Description
Output Channels 8 relay outputs
Relay Type Single make contact
Channel Isolation Electrically isolated outputs
Bus Interface Electrically isolated CS31 interface
Status Indication 8 yellow channel LEDs
Error Indication 1 red fault LED
Diagnostic Functions Integrated diagnosis display
Mounting Method Plug-in base ECZ
Test Function Front-panel test button

The ECZ plug-in base includes mechanical voltage coding to prevent installation with incorrect supply voltage configurations.

Technical Specifications

Parameter Value
Model ICSO 08 R1
Brand ABB
Product Type Digital Output Module
Series CS31
Output Channels 8 relay outputs
Output Type Relay make contact
Switching Current 2 A per channel
Total Output Current 16 A maximum
Contact Voltage 250 VAC maximum
AC Switching Power 500 VA maximum
DC Switching Power 60 W maximum
Minimum Switching Load 0.1 mA / 0.1 VDC
Relay Mechanical Life > 3 x 10^7 cycles
Relay Electrical Life > 1 x 10^5 cycles at 230 VAC / 2 A
Supply Voltage Options 24 VDC or 230 VAC
Max Power Dissipation 5 W
Bus Interface CS31 isolated system bus
LED Indicators Yellow status LEDs and red fault LED
Installation Method DIN rail or screw mounting
Mounting Depth 117 mm
Plug-in Base Weight 200 g
Module Weight 24 VDC Version 250 g
Module Weight 230 VAC Version 430 g

Ordering Data

Description Ordering Number
Plug-in Base ECZ FPR3700001R0001
ICSO 08 R1 24 V DC Module FPR3312101R1022
ICSO 08 R1 230 V AC Module FPR3312101R0026

FAQs

What is the purpose of the ECZ plug-in base?
The ECZ base provides electrical connection, mechanical mounting, and voltage coding protection for the module.

Can ICSO 08 R1 switch inductive loads directly?
Yes. However, ABB recommends external protection components such as free-wheeling diodes for DC loads and varistors for AC inductive loads.

Are the relay outputs electrically isolated?
Yes. Each relay output is electrically isolated from the module logic and from other channels.

What happens if the wrong supply voltage module is installed?
The ECZ mechanical coding system prevents installation with incorrect supply voltage configurations.


Engineering & Installation Guide

When switching inductive DC loads such as relay coils or solenoids, always install a free-wheeling diode across the load terminals. This reduces relay contact arcing and extends relay service life.

Maintain separation between relay output wiring and low-level analog signal cables inside the cabinet. Relay switching transients may introduce electrical noise into instrumentation circuits.

For long-term reliability, verify that the combined output current does not exceed the 16 A total module limit, especially in high-duty-cycle applications.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
سفید خاکستری سیاه
Country of origin
سوئد
Power source
برق DC برق متناوب

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...