B&R X20BB82 X20 System Expansion Bus Base Module

B&R X20BB82 X20 System Expansion Bus Base Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20BB82

  • Country of origin:ایالات متحده آمریکا

  • Product Type: X20 Bus Base Module

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Technical Overview

The B&R X20BB82 (X20BB82) is a heavy-duty backplane bus base module featuring two integrated expansion slots, engineered as the foundational mechanical and electrical interconnect for the standard B&R X20 IO platform. Developed for deployment in complex automation panels within automotive assembly plants, maritime vessel controls, and energy distribution stations, this structural bus component handles internal communication routing and power distribution to eliminate signal degradation and minimize machine downtime. The module establishes the internal X2X Link data connection and coordinates the 24 VDC primary I/O power bus across adjacent slices. Outfitted with heavy-duty internal backplane contacts, it delivers a permissible contact load of 10 A, allowing high-density digital and analog configurations to run continuously without overheating the panel assembly.

Technical Configuration

The mechanical architecture and backplane routing paths of this module are designed for flexible, high-density cabinet layouts:

  • Dual-Slot Infrastructure: Houses two distinct expansion slots on a single footprint, allowing technicians to plug in X20 I/O modules, power supply components, or interface slices side-by-side.

  • Omnidirectional Mounting: Supports both horizontal and vertical DIN rail installations without sacrificing mechanical retention or derating the internal 10 A contact bus.

  • Low-Loss Bus Tap: Consumes a maximum of 0.70 W from the internal X2X Link communication bus, preserving the bulk of the system power for downstream processing logic.

  • IP20 Finger-Safe Design: Complies fully with EN 60529 standards, providing a shielded backplane interface that prevents accidental contact with live components during maintenance windows.

Technical Specifications

Parameter Specification
Model X20BB82
Brand B&R
Origin Austria
Product Type X20 Bus Base Module
Expansion Slot Capacity 2 Slots
Nominal Bus Voltage 24 VDC
Permissible Contact Load 10 A
Internal Bus Power Consumption 0.70 W
Enclosure Protection Rating IP20 (per EN 60529)
Mounting Capability Horizontal or Vertical DIN Rail
Standard Operating Elevation 0 to 2000 m (No derating required)
High-Altitude Operating Limit Above 2000 m (Derate ambient temperature by 0.5 deg C per 100 m)
Weight 0.18 kg (Shipping Weight: 2.0 kg pack)

Industrial Application FAQs

  • How does high-altitude deployment affect the X20BB82 module?

    For installations up to 2000 m above sea level, the module operates at full performance limits. When installed above 2000 m, the thinner air reduces convective thermal dissipation. To compensate, technicians must reduce the maximum ambient temperature limit of the cabinet by 0.5 deg C for every 100 m of elevation above the 2000 m threshold.

  • Can I mix different types of X20 modules on the two slots of this bus base?

    Yes. The X20BB82 provides standard mechanical and electrical interfaces across both slots. You can install any combination of standard X20 digital I/O, analog input/output, or functional counter modules that match the physical slot form factor, provided the total current consumption does not exceed the 10 A contact load limit.

  • What happens if the power distribution requirement exceeds the 10 A contact load limit?

    The internal bus bars are rated for a maximum continuous current of 10 A. If your downstream I/O modules pull more than 10 A combined, you must break the power bus by inserting an isolated X20 internal power supply module onto a new bus base farther down the DIN rail stack.


Field Engineering and Installation Directives

BACKPLANE INTERLOCK WARNING: Never slide bus base modules together along the DIN rail while the 24 VDC main power supply or X2X Link bus is energized. Arcing across the gold-plated slide contacts will pit the metal surface, resulting in permanent communication jitter or intermittent power failure.

DIN Rail Alignment and Engagement

Snap the X20BB82 onto a standard 35 mm symmetric DIN rail. Slide the module firmly to the left to interlock its side contacts with the preceding bus base module. Ensure that the integrated locking lever on the top and bottom clicks completely into place. A misaligned bus base will prevent the plug-in I/O modules from seating properly, causing internal bus communication faults.

Multi-Slot Shielding Rules

If an expansion slot on the X20BB82 remains unoccupied during initial commissioning, install a standard X20 slot cover module over the empty pins. Leaving the internal backplane contacts exposed compromises the IP20 finger-safe rating and invites airborne conductive particulate matter or moisture to short-circuit the internal 24 VDC power rails.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
سفید خاکستری
Country of origin
ایالات متحده آمریکا
Power source
برق DC

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...