1 of 1

B&R X20CM0985 X20 System 3-Phase Energy Measurement Module

B&R X20CM0985 X20 System 3-Phase Energy Measurement Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20CM0985

  • Country of origin:ایالات متحده آمریکا

  • Product Type: Analog inputs

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The X20CM0985 (X20CM0985) is a sophisticated 3-channel analog input module designed for comprehensive power and energy measurement within the B&R X20 System. This module is engineered to monitor 3-phase electrical networks, supporting direct voltage inputs of up to 480 VAC and current inputs of 1 A or 5 A AC via external transformers. In energy-intensive industries such as plastics processing, metal fabrication, and large-scale manufacturing, the X20CM0985 provides the critical data required for load management, predictive maintenance, and energy efficiency auditing. By delivering high-precision measurements of active, reactive, and apparent power directly to the PLC, it enables engineers to optimize machine performance and reduce operational overhead through real-time grid analysis.

Technical Configuration

The X20CM0985 integrates complex signal processing within the standard X20 form factor. It features three independent channels for simultaneous current and voltage measurement, allowing for the calculation of phase angles and harmonic distortion. The internal hardware is robust, consuming 1.05 W from the X20 bus and 4 W for the internal I/O circuitry. It is designed for high-voltage environments with a rated input capacity of 120 VAC to 480 VAC, making it compatible with most global industrial power grids. The module utilizes specialized A/D converters to handle the AC waveforms, ensuring that peak values and RMS calculations are performed with minimal latency. With an IP 20 protection rating, it is intended for installation in controlled electrical cabinets where space-saving and modularity are prioritized.

Technical Specifications

Feature Specification
Model X20CM0985
Brand B&R (Bernecker + Rainer)
Module Type Analog Input / Energy Measurement
Number of Channels 3 (Current and Voltage)
Voltage Input Range 120 VAC to 480 VAC
Current Input Range 1 A or 5 A AC
Bus Power Consumption 1.05 W
Internal I/O Consumption 4 W
Degree of Protection IP 20
Operating Temp 0 to 55 deg C
Dimensions 12.5 x 99 x 75 mm
Shipping Weight 2.0 kg

Technical FAQs

Can the X20CM0985 measure power in both 3-phase and single-phase systems?

Yes, the module is designed for 3-phase systems but can be configured to monitor three individual single-phase circuits. This flexibility allows for the monitoring of multiple high-load single-phase actuators within a single machine using only one module.

Does this module require external current transformers (CTs)?

Yes, for current measurement, the X20CM0985 must be interfaced with external current transformers that provide a secondary output of either 1 A or 5 A AC. Direct connection of high-current power lines to the module will result in immediate hardware failure.

What specific electrical parameters can be calculated by the X20CM0985?

Beyond standard voltage and current, the module provides data for active power (W), reactive power (var), apparent power (VA), energy consumption (Wh), and power factor (cos phi). It also supports frequency measurement and basic harmonic analysis.


Engineering & Installation Guide

  • Current Transformer Polarity: When wiring the 1 A or 5 A current inputs, strict adherence to the S1 (k) and S2 (l) polarity is essential. Reversing the polarity on a single phase will result in incorrect power factor readings and negative energy calculations for that specific phase.

  • Voltage Path Protection: Always install 3-pole circuit breakers or fuses (typically rated at 1 A to 2 A) in the voltage measurement path between the power line and the X20CM0985. This protects the module and the X20 backplane from catastrophic failure in the event of a line-to-line short circuit within the measurement loop.

  • Shielding and Grounding: Given the proximity to high-voltage lines, the X20CM0985 is susceptible to electromagnetic interference. Ensure the X20 bus module is properly snapped onto a grounded DIN rail. Use shielded cables for the current transformer secondaries and ground the shield at a single point to prevent circulating ground currents from skewing measurement accuracy.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
سفید خاکستری
Country of origin
ایالات متحده آمریکا
Power source
برق متناوب

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...