The GE IC670ALG630 (IC670ALG630) is a high-performance 8-channel analog input module designed for the GE Field Control decentralized I/O system. This specialized module accepts 8 independent thermocouple or millivolt inputs, providing precise temperature monitoring for critical industrial processes such as power generation, chemical refining, and metal processing. By converting analog thermal signals into a 16-bit digital format (15 bits plus sign), the IC670ALG630 ensures high-resolution data acquisition, which is essential for maintaining system stability and reducing energy-intensive thermal fluctuations. Its ability to interface directly with various thermocouple types without external converters makes it a cost-effective solution for large-scale distributed temperature sensing.
The module architecture is built around a solid-state, optically-coupled multiplexer and an internal microprocessor that handles scaling, linearization, and advanced diagnostics.
| Attribute | Specification |
| Model |
IC670ALG630 |
| Brand | GE (General Electric) |
| Series |
Field Control |
| Module Type |
Thermocouple Analog Input |
| Number of Channels |
8 (Individually configurable) |
| Resolution |
15 bits + sign |
| Origin | USA |
| Weight | 0.38 kg |
| Dimensions | 135 x 45 x 100 mm |
| Operating Temp |
0 to 55 deg C ambient |
| Power Consumption |
195 mA maximum from BIU |
| Isolation |
1500 VAC (Input to Logic/Frame Ground) |
| Scan Time (60 Hz) |
Approximately 60 ms per point |
How is data reported in the PLC memory?
Each channel can be configured to report either linearized temperature (in tenths of degrees Celsius or Fahrenheit) or raw millivolt values (reported as 1/100 of a millivolt).
What happens if a sensor wire breaks during operation?
Unless suppressed in the configuration, the module performs an "Open Thermocouple" check every time a channel is read. If a break is detected, a diagnostic bit is set in the discrete input table, and further processing of that channel is halted to prevent false readings.
Can this module operate without a separate power supply?
Yes, this module does not require a separate field power supply; it draws its required operating current (up to 195 mA) directly from the Bus Interface Unit (BIU) backplane.