The 00705-A-1735 is a High Temperature Combustible Sensor designed for detecting hazardous gases in demanding industrial environments. This specialized sensor is engineered to maintain operational integrity in high-heat conditions, providing reliable monitoring of combustible gas concentrations.
This Honeywell sensing device is typically integrated into gas detection control systems to provide continuous protection and safety monitoring. It functions by measuring the combustible atmosphere and delivering a consistent drive current to the control equipment. The 00705-A-1735 is built to withstand extreme thermal conditions, ensuring accurate performance from -25 degC to +150 degC. Its robust construction makes it suitable for installation in Class I, Div 1 environments, supporting safety-critical infrastructure where combustible gases pose a constant threat.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Model | 00705-A-1735 |
| Product Type | High Temperature Combustible Sensor |
| Operating Temperature | -25 degC to +150 degC |
| Storage Temperature | -25 degC to +150 degC |
| Operating Humidity | 20% to 90% RH (continuous, non-condensing); 10% to 100% RH (intermittent) |
| Drive Current | 200mA +/- 2mA |
| Power Consumption | 0.7W |
| Calibration Flow Rate | 1.5 l/min +/- 0.1 l/min |
| Temp. Coefficient of Zero Point | Max 0.05% LEL Methane per degC |
| Shipping Weight | 1.5 Kg |
What is the primary function of the 00705-A-1735?
It is a combustible gas sensor intended for gas detection systems operating in high-temperature environments.
Can this sensor operate in humid environments?
Yes, it is designed for 20% to 90% RH continuous non-condensing operation and up to 100% RH under intermittent, non-condensing conditions.
What is the required calibration flow rate for this unit?
The recommended calibration flow rate is 1.5 l/min +/- 0.1 l/min.
Is this sensor suitable for hazardous locations?
Yes, it is UL certified for Class I, Div 1, Groups B, C, and D environments within the specified temperature range.