  • Manufacturer: BECKHOFF

  • Product No.: KL2889

  • Country of origin:آلمان

  • Product Type: HD Bus Terminal

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The KL2889 (KL2889) is a high-density (HD) 16-channel digital output terminal designed for the Beckhoff Bus Terminal system. This module is specifically engineered for ground-switching (low-side switching) applications, providing 0 V DC output to control actuators, relays, and indicator lamps. By utilizing High-Density packaging, the KL2889 integrates 16 discrete outputs into a slim 12 mm housing, significantly reducing the required DIN rail footprint in complex control cabinets. It is an ideal choice for high-volume I/O environments such as automotive assembly lines and modular packaging machinery, where space efficiency and high-speed point-to-point wiring are paramount.

Technical Configuration

The KL2889 hardware is built for simplicity and reliability within the K-bus architecture. It features a 1-wire connection technology with a direct plug-in technique for solid wire conductors, facilitating rapid tool-less installation. The output stage is designed for 0.5 A per channel and is fully short-circuit proof, featuring an integrated reverse voltage protection mechanism. The terminal maps 16 outputs directly into the process image, requiring no complex address or software configuration. Its 500 V electrical isolation between the K-bus and field potential ensures that the central controller remains protected from field-side electrical transients or inductive flyback during heavy-duty switching cycles.

Technical Specifications

Feature Specification
Model KL2889
Brand BECKHOFF
Origin Germany
Number of Outputs 16
Switching Type 0 V DC (Ground switching)
Nominal Voltage 24 VDC (-15 percent / +20 percent)
Max. Output Current 0.5 A per channel
Connection Technology 1-wire (High Density)
Breaking Energy < 100 mJ / channel
Current Consumption (K-bus) typ. 45 mA
Electrical Isolation 500 V (K-bus / field potential)
Operating Temperature 0 to +55 Celsius
Weight approx. 70 g

Technical FAQs

What is the benefit of "0 V switching" in the KL2889?

Ground switching (NPN style) is often used in specific industrial regions or with certain types of sensors and actuators that share a common positive rail. The KL2889 completes the circuit by connecting the load to the 0 V (ground) potential.

How does the "direct plug-in" technique work?

For solid wire conductors, you can simply push the stripped wire into the terminal point without tools. For stranded wires or those with ferrules, a standard screwdriver is used to actuate the spring, ensuring a gas-tight and vibration-resistant connection.

Can I use this terminal to drive small DC motors?

Yes, provided the motor's steady-state current does not exceed 0.5 A and the inductive breaking energy remains under 100 mJ. For larger inductive loads, an external freewheeling diode is recommended to protect the internal output stage.


Engineering & Installation Guide

  • Wiring for HD Terminals: Given the high density of 16 connections in a 12 mm width, it is critical to use the correct wire cross-sections. For optimal results, use ferrules for stranded wires (0.14 to 0.75 mm²) to prevent stray strands from causing short circuits between the tightly packed terminals.

  • 0 V Potential Management: Ensure that the 0 V field potential is correctly fed into the power contacts. Since this is a ground-switching module, all connected loads must have their positive side connected to a common 24 VDC rail, while the KL2889 manages the ground return path.

  • Heat Dissipation: When all 16 channels are active and driving the maximum 0.5 A load, the module generates internal heat. Ensure the control cabinet has adequate ventilation and observe the variable installation positions described in the technical documentation to prevent thermal derating.

  • Short-Circuit Handling: While the module is short-circuit proof, a persistent short will trigger the current limitation (< 7 A). It is best practice to monitor the system diagnostic LEDs; if the "Error" LED for a channel bank illuminates, investigate the field wiring immediately to prevent unnecessary stress on the polycarbonate housing.

 

Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
نقره‌ای
Country of origin
آلمان
Power source
برق DC

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...