1 از 1

Mitsubishi Electric FR-A840-00770-2-60 FR-A800 Variable Frequency Drive

Mitsubishi Electric FR-A840-00770-2-60 FR-A800 Variable Frequency Drive

فقط 10 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Mitsubishi Electric

  • شماره محصول: FR-A840-00770-2-60

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: Variable Frequency Drives

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 28000g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Speed and torque precision across heavy-duty industrial applications are driven by the Mitsubishi Electric FR-A840-00770-2-60 variable frequency drive. Operating on a 400V class three-phase supply, this high-performance inverter from the premier FR-A800 series delivers optimized motor control utilizing advanced vector regulation algorithms. The unit features standard 3C2 conformal circuit board coating to ensure exceptional reliability in harsh, corrosive environments, paired with an integrated EMC filter (-2 CA designation) to suppress electromagnetic interference.

Features

  • Advanced Real Sensorless Vector (RSV): Achieves high-torque, highly responsive speed control without requiring an external encoder.
  • Multi-Rating Architecture: Supports Super Light Duty (SLD), Light Duty (LD), and Normal Duty (ND) calibration modes to match variable load profiles.
  • Conformal Coating Protection: Circuit boards are treated with 3C2 protective layer (IEC 60721-3-3) to resist humidity, dust, and chemical vapors.
  • Integrated Safety Functionality: Dual-channel emergency stop circuit complying with SIL3 and PL e safety standards.
  • Built-In PLC Programming: Allows users to run custom control algorithms and basic automation sequences directly inside the drive processor.

Applications

  • Continuous material handling and heavy-duty conveyor networks.
  • Industrial hoist, gantry, and crane hoist control systems.
  • Heavy-duty positive displacement pumps and high-pressure extrusion machinery.
  • Automated fan control systems in harsh-environment HVAC and mining operations.

Technical Specifications Table

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Number FR-A840-00770-2-60
Inverter Series FR-A800 Series
Voltage Class 400 V Class (3-Phase 380V to 500V AC, 50/60Hz)
SLD Rated Current (Super Light Duty) 77 A
LD Rated Current (Light Duty) 62 A
ND Rated Current (Normal Duty) 57 A
Structure & Functionality Standard Model
Circuit Board Coating Conformal Coated (3C2), Non-Plated Conductor
Enclosure Protection Rating IP00 (Open Type)
Cooling Method Forced Air Cooling
Net Weight 23.0 kg
Shipping Weight (Calculated) 28.0 kg
Country of Origin Japan

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A840-00770-2-60 serves as a direct engineering upgrade for the legacy FR-A740-00770 VFD units. Control parameters and macro programs can be migrated smoothly using Mitsubishi FR Configurator2 software. However, physical terminal block profiles and dimension mounting patterns differ slightly; when retrofitting older enclosures, verify clearance depths and terminal adapter requirements.

Application Pitfalls & Engineering Notes

When utilizing this drive under heavy start-stop cycles (ND ratings), thermal accumulation in the internal transistor modules can accelerate. Always size the enclosure ventilation assuming continuous output dissipation at 40 degC ambient. If operations exceed 40 degC, linear current derating curves must be strictly programmed into the thermal protection parameters.

Commissioning & Wiring Tips

To ensure EMC directive compliance, ensure the internal EMC filter grounding jumper is fully engaged. Grounding should utilize a flat, braided copper ground strap directly bonded to the backplate. Standard round wire conductors can exhibit high impedance to high-frequency carrier-wave noise, leading to phantom faults on nearby low-voltage analog signal lines.

Installation Guidelines

CRITICAL SAFETY WARNING

Risk of electric shock and stored energy hazard. Always de-energize the incoming three-phase supply lines before handling wiring connections. Wait at least 10 minutes post-power down for the DC-bus capacitors to completely discharge. Verify the DC bus voltage reads 0V using a calibrated digital multimeter at the terminal terminals before starting work.

1

Mount the inverter vertically to a rigid, non-flammable vertical backplate inside an industrial panel, ensuring minimum top and bottom clearances of 100mm for optimal convection airflow.

2

Connect the main three-phase AC power input lines to supply terminals R/L1, S/L2, and T/L3. Connect the three-phase motor leads to output terminals U, V, and W.

3

Route low-voltage control signals, analog speed references, and communications through shielded twisted-pair (STP) wiring channels separate from main AC and motor cabling.

4

Perform initial power-up. Navigate the PU keypad controller interface to input fundamental motor parameters, maximum operating frequency, acceleration/deceleration ramps, and designated overload trip values.

Loading product navigation…

What does the -2-60 suffix mean on this model?

The '-2' suffix designates the CA (China/Asia/Europe functional specification) terminal configuration with built-in EMC filter capabilities, and '-60' indicates that the internal circuit board features class 3C2 conformal coating, without silver-plated conductors.

What are the rated output currents for different duty classes on this drive?

The unit is rated for Super Light Duty (SLD) at 77 A, Light Duty (LD) at 62 A, and Normal Duty (ND) at 57 A. Overload capacities vary based on these parameter settings.

Can this inverter run closed-loop vector control?

Yes, but standard closed-loop vector control requires installing an optional plug-in encoder interface card (such as the FR-A8AP) to process encoder feedback signals.

What is the recommended discharging time before servicing?

You must wait at least 10 minutes after disconnecting all primary input power sources to allow the internal DC bus capacitors to drop below hazardous voltage levels.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...