راهنمای جامع فایروالهای صنعتی و تقسیمبندی شبکه OT
فایروالهای صنعتی نقش حیاتی در امنیت سایبری OT ایفا میکنند و از شبکههای PLC، DCS و SCADA از طریق بخشبندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت میکنند.

The Siemens 6ES7718-1CC05-0AC0 SIMATIC Field PG M6 Advanced is a robust, portable programming device engineered for demanding industrial automation tasks. This professional mobile workstation features a powerful Intel Core i7-8850H processor operating from 2.6 to 4.3 GHz, complete with 6 kernels, hyper-threading, and a 9 MB Smart Cache. Visuals are delivered via a sharp 15.6-inch Full HD (1920x1080) display backed by integrated UHD Graphics 630. For seamless multitasking and extensive project data storage, it comes equipped with 32 GB DDR4 SD-RAM (1x SO-DIMM) and a high-capacity 2 TB SSD SATA (2.5") drive.
High-speed wireless deployment is fully supported through integrated WLAN 802.11ac and Bluetooth V5.0 hardware, alongside an integrated DVD +/-RW optical drive. Operating on an embedded Windows 10 Pro or Windows 11 Pro system architecture, this configuration is pre-loaded with engineering licenses for STEP 7 Professional Combo, WinCC Advanced Combo, and Safety Advanced Combo (all version V15.1), establishing a turnkey environment for TIA Portal applications. Please note this hardware revision does not feature an S5 interface or an S5-EPROMMER hardware link, and it ships configured with a UK power plug standard and a standard QWERTZ/QWERTY layout keyboard panel.
| Product Component | Technical Specification Details |
|---|---|
| General Framework |
Manufacturer: Siemens Product Range: SIMATIC Field PG Subrange Variant: Field PG M6 Advanced Lifecycle Status: Phase-Out Product Type: Industrial Programming Device |
| Processing Architecture |
CPU model: Intel Core i7-8850H (2.6 GHz base, up to 4.3 GHz turbo boost) Core Configuration: 6 Cores with hyper-threading processing technology Processor Cache: 9 MB Smart Cache |
| Display & Graphics |
Screen Dimension: 15.6 inch diagonal Native Resolution: Full HD (1920x1080 pixels) Graphics Processor: Integrated Intel UHD Graphics 630 |
| Memory & Solid Storage |
RAM Capacity: 32 GB DDR4 SD-RAM (1x SO-DIMM form factor) Internal Storage: 2 TB SSD SATA (2.5" form factor drive) M.2 NVMe Slot: Without internal M.2 NVMe card module |
| Interfaces & Peripherals |
Wireless Networking: WLAN 802.11ac protocol support Local Connectivity: Integrated Bluetooth V5.0 controller Optical Read/Write: DVD +/-RW media drive S5 Interface Link: Without legacy S5 connector interface S5-EPROMMER: Without legacy hardware programming interface |
| Software Environment |
Operating System: Embedded Windows 10 Pro or Windows 11 Pro Pre-installed Licenses: STEP 7 Professional Combo, WinCC Advanced Combo, Safety Advanced Combo Engineering Version: V15.1 Software Framework Compatibility |
| Hardware Form & Plug |
Mains Cord Type: UK Power Plug standard Keyboard Profile: QWERTZ/QWERTY dual notation layout |
| Logistics Parameters |
Shipping Weight: 3.20 kg Commodity Code: 84713000 Export Regulations (ECCN): 5A992 Calculated Packaging Envelop: 39.50 x 30.00 x 17.00 cm |
| Deployment Phase | Required Technical Step & Engineering Action |
|---|---|
| Step 1: Unpacking & Inspection | Carefully open the protective transport carton, extract the Field PG M6 device, and perform a complete visual assessment to check for signs of physical shipping distortion. Retain the specialized original packaging inserts to ensure secure transit during future field relocations. |
| Step 2: Power Grid Connection | Plug the supplied factory UK AC power cord connection firmly into the device's main power supply adapter block, then connect the standard plug to a stable grounding mains outlet source that complies with the exact electrical parameters of the system hardware. |
| Step 3: First Boot Setup | Depress the power terminal switch to activate the programming unit. Follow the sequential on-screen installer prompts to complete the primary operating system parameters, including default localization language settings, keyboard inputs, regional clocks, and secure supervisor administrative accounts. |
| Step 4: Automation License Activation | Initialize the pre-loaded automation workspace software. Access the integrated licensing framework utilities to activate and allocate the STEP 7 Professional Combo, WinCC Advanced Combo, and Safety Advanced Combo (V15.1) product authorization strings exactly as specified by factory instructions. |
| Step 5: Peripheral Interface Linkage | Terminate all necessary communication media, external engineering display monitors, industrial USB hardware dongles, or direct industrial Ethernet network cables to the matching physical interface ports to run targeted distributed network tests. |
| Step 6: Environmental Management | Operate this advanced programming device strictly inside the engineering parameters defined for ambient room temperature and relative atmospheric humidity levels. Maintain clean airspace around the device ventilation intakes to protect internal boards from dense dust tracking, moisture buildup, or direct exposure to high solar radiation. |
| Step 7: Cybersecurity Practices | Enforce robust local access control configurations across the operational framework. Set up highly complex administrative passwords, activate network firewall filters, and establish structured security patches to defend your connected plant automation platforms from cyber risks. |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
آلمان
|