The X20BR9300 (X20BR9300) is a fundamental infrastructure component of the B&R X20 System, serving as the primary bus receiver to interface local I/O segments with the X2X Link backplane. This module provides the essential feed for the X2X Link communication lines and the internal I/O supply, ensuring seamless data flow and power distribution across the terminal block. In large-scale industrial automation layouts—such as distributed control systems in bottling plants, automotive assembly lines, and textile machinery—the X20BR9300 acts as the gateway for remote I/O expansion. By offering electrical isolation between the feed and the X2X Link supply, it protects the system from potential electrical interference, while its support for redundant supply configurations ensures maximum uptime in mission-critical environments.

Technical Configuration

The hardware architecture of the X20BR9300 is designed for specific placement and high reliability. It must be operated exclusively on the slot to the far left of an I/O station to correctly initialize the bus segment. The module integrates a dual-purpose feed mechanism that powers both the internal communication logic and the attached I/O modules. A key feature of this unit is the ability to operate multiple supply modules simultaneously, allowing for redundancy in the X2X Link power supply; if one supply fails, the system continues to operate without interruption. The electrical isolation between the input power and the internal bus logic prevents ground loops and voltage spikes from damaging the sensitive communication architecture. For a complete installation, the module is supplied with both the left and right end plates to ensure proper mechanical termination of the X20 rack.

Technical Specifications

Feature Specification
Model X20BR9300
Brand B&R (Bernecker + Rainer)
Module Type X2X Link Bus Receiver
Function Feed for X2X Link and Internal I/O
Isolation Electrical isolation between feed and bus
Redundancy Supported (via simultaneous supply modules)
Slot Requirement Far left slot only
Included Accessories Left and right end plates
Operating Temp 0 to 55 deg C
Protection Rating IP20
Shipping Weight 2.0 kg

Technical FAQs

Why must the X20BR9300 always be placed in the far left slot?

The far left slot is the hardware-defined entry point for the X2X Link bus. The receiver must occupy this position to correctly establish the electrical termination and signal direction for all subsequent I/O modules in the segment.

Can I use two X20BR9300 modules in a single segment for power redundancy?

Yes. By operating multiple supply modules simultaneously, the X2X Link supply becomes redundant. If one module loses its input feed, the other modules will maintain the bus voltage, preventing a communication timeout and system halt.

What is the purpose of the electrical isolation in this receiver?

The isolation separates the external 24 VDC supply from the internal logic voltage used by the X2X Link. This barrier prevents field-side electrical noise or faults from entering the backplane, ensuring stable data transmission across long distances.


Engineering & Installation Guide

  • Mechanical Termination: Always install the included left and right end plates. The end plates are not merely cosmetic; they provide the necessary mechanical tension to keep the X20 modules securely mated and protected from environmental dust that could cause intermittent contact issues.

  • Redundant Power Wiring: When configuring for redundancy, ensure that both power feeds originate from stable, industrial-grade power supplies. It is recommended to use the same voltage potential for both feeds to ensure balanced current sharing across the redundant modules.

  • X2X Link Distance: While the X20BR9300 facilitates the connection, the maximum distance between X2X Link stations is typically 100 meters. For segments approaching this limit, ensure the use of high-quality shielded twisted-pair cables and verify that the bus receiver is correctly grounded to the DIN rail to maintain signal integrity.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
سفید خاکستری
Country of origin
ایالات متحده آمریکا
Power source
برق DC

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...