1 de 3

Module d'alimentation secteur universel 3500/15 Bently Nevada 106M1079-01

Module d'alimentation secteur universel 3500/15 Bently Nevada 106M1079-01

Il ne reste que 4 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 3500/15 106M1079-01

  • Pays d'origine :États-Unis

  • Type de produit : Module d'alimentation secteur universel

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 1390g

  • Dimensions : 120,7 mm x 50,8 mm x 251,5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Bently Nevada 106M1079-01 is a half-height Universal AC Power Supply Module engineered for the 3500 Series Machinery Protection System. This module serves as a primary or redundant power source, converting a broad range of high-voltage alternating current inputs into stable regulated internal voltages required by other monitoring and communication modules in the same rack. It must be installed in designated slots on the left side of the 3500 rack structure, where it can provide full system power independently or run in tandem with a secondary backup power supply without interrupting ongoing machinery protection operations. The 106M1079-01 configuration ensures steady electrical delivery for continuous vibration, position, and speed monitoring functions in critical high-speed rotating industrial machinery setups.

Features

  • Half-height module construction optimizing left-side rack slot utilization
  • Supports full rack power delivery from a single module solution
  • Hot-swappable dual-redundancy architecture permitting live replacement without disrupting operational monitor channels
  • Integrated front-panel "SUPPLY OK" LED status indicator for immediate technical validation
  • Broad universal AC input tolerance adapting directly to fluctuating plant electrical grids

Applications

  • Redundant power distribution for critical 3500 Series Machinery Protection Systems
  • Continuous turbine, compressor, and large motor vibration tracking stations
  • High-availability oil, gas, and power generation industrial processing facilities

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (A Baker Hughes Company)
Model 106M1079-01
Product Type Universal AC Power Supply Module
Nominal Input Voltage 110 to 220 Vac nominal
Input Voltage Range (Non-hazardous areas) 85 to 264 Vac rms
Input Voltage Range (Hazardous areas) 85 to 250 Vac rms
Input Peak Voltage 120 to 373 Vac pk
Input Frequency 47 to 63 Hz
Full Rack Current Draw 2.8 A rms (maximum)
Module Dimensions (H x W x D) 120.7 mm x 50.8 mm x 251.5 mm (4.75 in x 2.0 in x 9.9 in)
Module Weight 1.39 kg (3.06 lb)
Operating Temperature -30 degC to +65 degC (-22 Fahrenheit to +150 Fahrenheit)
Storage Temperature -40 degC to +85 degC (-40 Fahrenheit to +185 Fahrenheit)
Humidity 95%, non-condensing
Country of Origin United States

Connections/Interfaces

Interface Component Function
Front Panel LED SUPPLY OK LED indicates when the power supply is operating properly
Rear PIM Interface Links directly to the matching Universal AC Power Input Module (PIM) behind the supply slot

Installation Guidelines

  • Slot Allocation: Ensure the power supply module is inserted exclusively into the half-height slots located on the left side of the 3500 machinery protection rack.
  • Redundancy Setup: When configuring a dual-redundant power setup, install the primary module in the lower slot and the backup module in the upper slot.
  • Module Compatibility: Do not attempt to mate the universal AC power supply with legacy High Voltage AC or Low Voltage AC PIMs, as they are completely incompatible.
  • Ventilation and Environment: Ensure proper clearance and air cross-flow to maintain ambient operations within the boundaries of -30 degC to +65 degC.

Compliance and Certifications

  • FCC: Complies with part 15 of the FCC Rules.
  • EMC Directives: European Community Directive 2014/30/EU; Standards EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions).
  • Electrical Safety: European Community Directive: LV Directive 2014/35/EU; Standards: EN 61010-1.
  • RoHS: European Community Directive 2011/65/EU.
  • Maritime: DNV GL rules for classification (Ships, offshore units, high speed/light craft); ABS Rules for Condition of Classification Part 1, Steel Vessels Rules, Offshore Units and Structures.
  • North American Hazardous Area Approvals (CNRTLUS): Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC.
  • ATEX/IECEx: II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC.

FAQ

What happens if one power supply fails in a dual-supply system?

If two power supplies are installed, the lower module is the primary and the upper is the backup. If one fails, the other automatically maintains full rack operation without any disruption to the system.

Is this module backwards compatible with older legacy Bently Nevada power inputs?

No. The universal AC power supply module and its corresponding Power Input Module (PIM) are entirely incompatible with legacy 3500 AC power supplies and legacy PIM components.

What fuse should be used to protect the associated power entry interface?

The matching universal AC Power Input Module utilizes a fast-blow replacement fuse rated at 5A/500 Vac with physical dimensions of 6.3 mm x 32 mm.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Argent Noir
Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...