1 de 3

Bently Nevada 140482-01 3500/42M Prox/Velom I/O Module with External Terminations

Bently Nevada 140482-01 3500/42M Prox/Velom I/O Module with External Terminations

Il ne reste que 4 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 140482-01

  • Pays d'origine :États-Unis

  • Type de produit : I/O Modules

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 200g

  • Dimensions : 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Bently Nevada 140482-01 is a Prox/Velom I/O module with external terminations designed for signal interfacing between transducers and the 3500/42M Proximitor Seismic Monitor or 3500/72M Recip Rod Position Monitor. The module routes input signals from Proximitor, accelerometer, Velomitor, or HTVS transducers located in the field through the rear slot of a 3500 system rack directly into the main monitor board. It conditions incoming signals and delivers power supply outputs while maintaining signal integrity for 4-channel vibration and position monitoring operations.

Features

  • Accepts inputs from Proximitor, accelerometer, Velomitor, or HTVS transducers
  • External termination interface design for off-rack field wiring connection
  • Supports multi-channel signal routing to the 3500/42M and 3500/72M monitor main boards
  • Occupies 1 full-height rear slot in the 3500 system rack

Applications

  • Machinery protection and condition monitoring
  • Hydro-turbines, gas turbines, and steam turbines
  • Reciprocating compressor rod position and drop monitoring
  • Industrial pumps, fans, and motor assemblies

Ordering Information

Part / Option Description
140482-01 Prox/Velom I/O Module with External Terminations
125808-08 Proximitor / Velomitor External Termination Block (Euro Style Connectors)
128015-08 Proximitor / Velomitor External Termination Block (Terminal Strip Connectors)
129525-AAAA-BB 3500 Transducer XDCR signal to External Termination Block Cable
00561941 3500/42M Prox/Velom I/O Module 10-pin connector shunt

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (a Baker Hughes Company)
Model 140482-01
Module Type Prox/Velom I/O Module with External Terminations
Compatible Transducers Prox/Accel, Velomitor, HTVS
Supply Parameters (Prox/Accel) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Supply Parameters (Velomitor) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Rack Space Requirement 1 full-height rear slot
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Weight 0.20 kg (0.44 lb)

Installation Guidelines

  • Install the module into 1 full-height rear slot corresponding to the associated front monitor module in the 3500 rack.
  • Connect the external termination block to the rear module using the designated 129525 external termination cable.
  • Ensure proper field wiring connection on the external termination block with supported transducer types.
  • Do not attempt to use external termination blocks with internal termination I/O modules.

Compliance and Certifications

Category Standard / Certification
EMC EN 61000-6-2, EN 61000-6-4 (Directive 2014/30/EU)
Electrical Safety EN 61010-1 (Directive 2014/35/EU)
RoHS Directive 2011/65/EU; China RoHS EFUP 15 years (SJ/T 11364-2024)
Hazardous Area (cNRTLus) Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (T4 @ Ta= -20 degC to +65 degC)
Hazardous Area (ATEX/IECEx) II 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta= -20 degC to +65 degC)
Maritime ABS-Marine and Offshore Applications; DNV GL Rules for Classification
Loading product navigation…

Where is the I/O module installed in the 3500 system rack?

The module installs in 1 full-height rear slot directly behind the matching monitor module.

Which transducer types can connect to this external termination module?

The device accepts Proximitor, accelerometer, Velomitor, and HTVS transducer inputs.

What cable is used to connect the module to the external termination block?

The module connects via the 129525 transducer signal to external termination block cable.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats Arabes Unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Argent
Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernisation des IHM Bailey INFI 90 Symphony fonctionnant sous OpenVMS Alpha

Un guide pratique pour remplacer les postes opérateur vieillissants Bailey Symphony fonctionnant sous OpenVMS Alpha. Il compare l’émulation Alpha, la migration vers OpenVMS x86, la refonte basée sur...

Pourquoi les données de maintenance sont essentielles à la fiabilité industrielle

Les données de maintenance relient les ordres de travail, les signaux des capteurs, l’historique des actifs, les coûts et les connaissances des techniciens. Lorsqu’elles sont bien exploitées, elles...

Actionneurs électriques conçus pour remplacer les systèmes de puissance fluidique : guide pratique de l’automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle des mouvements industriels en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour des applications d’automatisation industrielle

Cet article explique comment les systèmes API réalisent des opérations mathématiques essentielles telles que l’addition, la soustraction, la multiplication, la division, le modulo et l’exponentiation...