1 de 3

Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer

Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer

Il ne reste que 3 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 330880-28-15-035-00-02

  • Pays d'origine :États-Unis

  • Type de produit : PROXPAC XL Proximity Transducer

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 250g

  • Dimensions : 60 mm x 110 mm x 110 mm (H x W x D)

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Option 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 15 (1.5 in standoff adapter) specify this PROXPAC XL Proximity Transducer configuration — 330880-28-15-035-00-02.

This integrated proximity transducer assembly combines the probe and Proximitor sensor into a single polyphenylene sulfide (PPS) housing. The self-contained design eliminates the need for an external extension cable between the probe and Proximitor sensor, as well as the need for a separate Proximitor junction enclosure. Field wiring connects directly between the monitors and the internal terminals. This configuration features a 3.5 in probe penetration depth (Option 035), no conduit fittings (Option 00), and a 3/4-14 NPT mounting thread (Option 02) suitable for severe industrial machinery case interfaces.

Features

  • Transducer probe with multiple hazardous area approvals (ATEX, IECEx, and CSA) for explosion-proof and intrinsically safe installations.
  • Integrated Proximitor sensor in the housing lid to eliminate external extension cables.
  • Conductive glass-fiber-reinforced polyphenylene sulfide (PPS) thermoplastic housing rated IP66 and Type 4X.
  • 1.5 in (38 mm) standoff adapter with a 3/4-14 NPT thread for rigid casing mounting.
  • 3.5 in (89 mm) stainless steel probe sleeve length for direct case penetration.
  • Supplied with two plugs and two washers under the no-fittings option.

Applications

  • Shaft vibration and axial position measurements on rotating machinery.
  • Direct integration on turbines, compressors, pumps, and industrial gearboxes.
  • Environments requiring IP66 or Type 4X protection against chemical exposure, moisture, and dust.
  • Hazardous industrial environments requiring intrinsically safe or non-incendive field wiring.

Ordering Information

Option / Segment Code on This SKU Description
Orderable Part Number 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer, English
A - Probe and Approvals Option 28 3300 XL 8 mm probe with Multiple Approvals
B - Standoff Adapter Option 15 1.5 in (38 mm) standoff length
C - Probe Penetration Option 035 3.5 in (89 mm) penetration length
D - Fittings Option 00 No fittings; two plugs and two washers
E - Mounting Thread Option 02 3/4-14 NPT mounting thread (required with standoff adapter)

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number 330880-28-15-035-00-02
System Component Integrated Proximity Transducer Assembly
Linear Range 2 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)
Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/- 5%
Input Voltage Requirement -17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)
Output Resistance 50 Ohm
Frequency Response 0 to 10 kHz (+0, -3 dB) with up to 305 m (1000 ft) of field wiring
Minimum Target Size 15.2 mm (0.6 in) diameter flat target
Shaft Diameter Limits Minimum 50.8 mm (2.0 in), Recommended 76.2 mm (3.0 in)
Housing Material UV-resistant, glass-reinforced conductive polyphenylene sulfide (PPS)
Probe Case and Sleeve Material AISI 304 stainless steel
Probe Tip Material Polyphenylene Sulfide (PPS)
Operating Temperature (Probe) -52 degC to +177 degC
Operating Temperature (Housing/Sensor) -52 degC to +100 degC
Storage Temperature Range -52 degC to +105 degC
Environmental Protection IP66 and Type 4X when properly sealed

Installation Guidelines

  • Torque the housing retaining nut to 29.5 N-m (260 in-lb).
  • Torque the probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain the environmental pressure seal.
  • Verify that the internal grounding liner and retaining plate are clean and securely fastened.
  • Ensure field wiring terminals are protected by an enclosure of at least IP54.
  • Maintain a minimum separation of 40 mm (1.6 in) for axial installations or 38 mm (1.5 in) for radial configurations to avoid cross-talk.

Compliance and Certifications

ATEX/IECEx Ex ia IIC T4/T5 Ga, Ex ia IIIC T90C/T105C Dc (Intrinsically Safe); Ex nA IIC T4/T5 Gc, Ex ec IIC T4/T5 Gc (Non-sparking)
North American (cNRTLus) Class I, Zone 0: AEx/Ex ia IIC T4/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III (Intrinsically Safe)
Non-Incendive Class I, Division 2, Groups A, B, C, D; Class I, Zone 2: AEx/Ex nA IIC T4/T5 Gc
CE Mark Complies with European directives
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer

What does the A: 28 option indicate for the 330880 assembly?

The A: 28 option indicates that this assembly is equipped with a 3300 XL 8 mm proximity probe and holds Multiple Approvals for hazardous locations, such as ATEX, IECEx, and CSA certifications.

Is an external extension cable required for this PROXPAC XL transducer?

No, the PROXPAC XL integrates both the probe and the Proximitor sensor inside a single thermoplastic housing lid. This design eliminates the need for an external extension cable and separate Proximitor junction box.

What is the penetration depth and mounting thread on this specific model?

The model features a probe penetration length (C option) of 3.5 inches (89 mm) and a 3/4-14 NPT mounting thread (E option), which is required because it includes a 1.5-inch standoff adapter.

What fittings are supplied under the D: 00 option?

The D: 00 option means the transducer assembly is supplied with no conduit fittings. Instead, it comes equipped with two plugs and two washers for custom or existing conduit entries.

What is the environmental rating of the housing?

The housing is constructed from glass-reinforced conductive polyphenylene sulfide (PPS) and is rated IP66 and Type 4X for protection in severe, corrosive, and wet industrial environments.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats Arabes Unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle de mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent les opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il couvre...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par les...