1 de 3

Module d'interface de rack Bently Nevada 3500/20-02-02-00 125744-01 TMR

Module d'interface de rack Bently Nevada 3500/20-02-02-00 125744-01 TMR

Il ne reste que 7 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 3500/20-02-02-00 125744-01

  • Pays d'origine :États-Unis

  • Type de produit : Module d'interface de rack TMR

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 1360g

  • Dimensions : 241,3 mm x 24,4 mm x 241,8 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Rack Interface Module (RIM) serves as the primary gateway and processing interface for the 3500 Series machinery protection system. It establishes a connection via a proprietary protocol to facilitate comprehensive rack configuration and real-time machinery data retrieval. Designed exclusively for localized layout tracking, this module must reside in slot 1 of the rack assembly, immediately adjacent to the system power supplies.

This specific configuration 3500/20-02-02-00 functions as a Triple Modular Redundant (TMR) version equipped with a dedicated RS232/RS422 serial I/O interface. Beyond performing standard communication management, the TMR architecture executes continuous monitor channel comparison and monitor voting logic by cross-referencing outputs across three redundant monitors. If an output variation exceeds the pre-configured percentage limits, the module flags the respective monitor as faulted and logs a distinct entry within the System Event List. While the unit supports vital rack-wide functions, it remains separated from the critical machinery monitoring path, ensuring its operation has no adverse impact on normal, ongoing safety protection loops.

Features

  • Monitor Channel Comparison: Dynamically cross-checks and processes diagnostic data from three redundant monitoring cards to maintain TMR system voting integrity.
  • Dual Serial Communication: Employs a versatile rear I/O module supporting both RS232 and RS422 protocol media options via an integrated hardware toggle switch.
  • Comprehensive Diagnostic LEDs: Provides upfront status visualization via dedicated front-panel indicators for module health, communication activity, Trip Multiply status, and configuration validity.
  • Hardware Configuration Keylock: Includes a physical front-panel switch to secure the rack in RUN mode against unauthorized remote or local modification, or enable changes via PROGRAM mode.
  • System Contact Inputs: Incorporates discrete dry contact inputs to handle systemic controls including remote alarm inhibit, rack reset, and Trip Multiply triggering.

Applications

  • Triple Modular Redundant (TMR) safety and machinery protection layouts.
  • Continuous condition monitoring and diagnostic data routing for critical industrial rotating assets.
  • Distributed multi-rack turbomachinery instrumentation networks requiring daisy-chained serial host interfaces.

Ordering Information

Model Code Description
3500/20 Rack Interface Module
-02 Rack Interface Type: TMR RIM (Use only for application that requires a Triple Modular Redundant Configuration)
-02 Type of I/O Module: I/O module with RS232/RS422 interface
-00 Agency Approval Option: None

Note: The individual component spare part number representing the TMR Rack Interface Module main card is 125744-01.

Technical Specifications

Category Parameter Specification
Electrical Power Consumption 4.75 watts, typical
  Maximum Current (Contacts) <1 mA dc, Dry Contact to Common
I/O & Relay OK Relay Type Normally Energized, user-selectable Open or Closed contact for Not OK indication
  Relay Rating 5A @ 24 Vdc / 120 Vac, 120 Watts / 600 VA Switched Power
  Arc Suppression Provided on contacts
Communication Front Panel Port RS232 serial only, Bently Nevada proprietary protocol, 38.4 k baud max (auto-baud capable), 30 metres (100 feet) max cable length
  I/O Module Serial Ports RS232 / RS422, Bently Nevada proprietary protocol, 38.4 k baud max (auto-baud capable)
  RS232 Cable Distance 30 metres (100 feet) maximum
  RS422 Cable Distance 1200 metres (4000 feet) maximum
  Daisy-Chain Port RS422 only, Bently Nevada proprietary protocol, 38.4 k baud max, 1200 metres (4000 feet) max
Environmental Operating Temperature -30 Celsius to +65 Celsius (-22 Fahrenheit to +150 Fahrenheit)
  Storage Temperature -40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit)
  Humidity 95%, non-condensing
Mechanical RIM Module Dimensions 241.3 mm x 24.4 mm x 241.8 mm (9.5 in. x 0.96 in. x 9.52 in.)
  RIM Module Weight 0.91 kg (2.0 lb.)
  RS232/RS422 I/O Dimensions 241.3 mm x 24.4 mm x 99.1 mm (9.50 in. x 0.96 in. x 3.90 in.)
  RS232/RS422 I/O Weight 0.45 kg (1.0 lb.)
  Combined Total Weight 1.36 kg (3.0 lb.)
  Space Requirements 1 full-height front slot (Main Board) and 1 full-height rear slot (I/O Module)
  Manufacturer Bently Nevada (A Baker Hughes Company)
  Country of Origin USA

Installation Guidelines

  • Slot Assignment: Mount the primary processor card strictly into Slot 1 on the far left side of the front chassis, directly adjacent to the system power supply modules.
  • Rear I/O Alignment: Install the corresponding RS232/RS422 I/O module into the matching full-height rear slot directly behind the front processor module.
  • Protocol Selection: Set the onboard rear slide switch to either the RS232 position or RS422 position based on the physical interface configuration of your host computer or converter.
  • Rack Addressing: Utilize the integrated hardware address switch to define a unique tracking identification code for the chassis when deploying multiple racks in a network loop.
  • Wiring Extensions: Do not exceed 30 metres for RS232 connections or 1200 metres for RS422 connections to avoid serial data packet loss or signaling degradation.

FAQ

What is the functional difference between a standard RIM and a TMR RIM?

The standard version handles configuration and communication routing for standard racks. The TMR variant adds specific hardware comparison algorithms that continually evaluate outputs from three distinct monitors to implement fault voting logic.

Will a failure or removal of this module interrupt the active machinery trip protection loop?

No. This module handles rack infrastructure setup, communication, and system-wide logging, but it does not reside within the critical safety monitoring path and has no impact on individual monitor operations.

How can I restrict unauthorized users from altering the machinery protection settings remotely?

Turn the front-panel configuration keylock into the RUN position and remove the physical key. This locks out remote and local programming, preventing modifications to active operational thresholds.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre Argent
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...