1 de 3

Module de sortie relais 16 canaux à faible courant Bently Nevada 3500/33-03-00 149992-03

Module de sortie relais 16 canaux à faible courant Bently Nevada 3500/33-03-00 149992-03

Il ne reste que 7 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 3500/33-03-00 149992-03

  • Pays d'origine :États-Unis

  • Type de produit : Module de sortie relais

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 1230g

  • Dimensions : 241,3 mm x 24,4 mm x 241,8 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Bently Nevada 3500/33-03-00 149992-03 is a full-height 16-channel relay output module designed to provide advanced programmable safety voting and alarm drive logic for the 3500 Series Machinery Protection System. As a factory-configured low-current assembly, the 3500/33-03-00 149992-03 features specialized gold-plated relay contacts engineered specifically to ensure maximum contact integrity and prevent surface oxidation in low-power signaling applications. Each of its sixteen independent outputs possesses dedicated Alarm Drive Logic, allowing operators to program complex combinational AND/OR logic gates utilizing alert, danger, or Not-OK statuses gathered from any vibration, position, or temperature monitor module across the rack. This combined hardware and software solution serves as a highly reliable, hardware-voted emergency trip bridge between critical plant rotating assets and external Distributed Control Systems (DCS), programmable logic controllers (PLC), or Emergency Shutdown Systems (ESD).

Features

  • Complete integrated 16-channel safety relay assembly consisting of the 3500/33-03-00 system code and the 149992-03 gold-contact main processor board.
  • Onboard gold-plated contacts optimized for highly stable low-voltage and low-current circuit switching.
  • Highly flexible Alarm Drive Logic matrix supporting customized voting schemes based on multi-channel alert and danger variables.
  • Live-swap hot-pluggable architecture enabling seamless physical card replacement without disturbing adjacent online machinery protection loops.
  • Individual hardware switch assignments on the circuit board allowing independent Normally Energized (NE) or Normally De-energized (NDE) configuration per relay.
  • Clear front-panel LED diagnostics providing real-time visual assessment of module health (OK), backplane communication bus activity (TX/RX), and individual channel alarm states.

Applications

  • Low-current alarm link interfaces connecting heavy rotating machinery protection racks to industrial PLCs and safety controllers.
  • Distributed logic voting and automated emergency shutdown mapping for high-criticality steam turbines, gas turbines, and compressors.
  • Multi-point protective trip signaling inside demanding petrochemical facilities, oil refineries, and power generation stations.

Ordering Information

Ordering Code / Component Part Number Description
3500/33-03-00 16-Channel Relay Module complete assembly with Low Current Relays, No Agency Approvals.
A: 03 Low Current Relay Module option (utilizes Output Module with Gold Contacts).
B: 00 Agency Approval Option: None.
149992-03 Main Board Component: Low Current 16-Channel Relay Main Module with Gold-Plated Contacts.

Technical Specifications

Parameter Category Specification Details
Manufacturer Bently Nevada (Baker Hughes)
Combined Designation 3500/33-03-00 149992-03
Module Type 16-Channel Relay Module (Low Current Gold Variant)
Power Consumption 5.8 Watts typical
Relay Contact Type Single-pole, double-throw (SPDT) / Gold-plated contacts
Minimum Contact Load 1 V, 1 mA minimum
Maximum Contact Load 30 Vdc at 2 A resistive / 48 Vdc at 0.2 A resistive / 125 Vdc at 0.1 A resistive / 250 Vac at 2 A resistive
Contact Operation Mode Onboard switch-selectable for Normally De-energized (NDE) or Normally Energized (NE)
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 95%, non-condensing
Main Card Dimensions 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
I/O Card Dimensions 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Main Module Weight 0.82 kg (1.8 lb)
I/O Module Weight 0.41 kg (0.9 lb)

Connections/Interfaces

The diagnostic readouts on the front and the physical terminations on the rear facilitate distinct interface tracking:

Component Identifier Functional Description / Assignment
OK LED Front panel health light; remains solid green when internal software algorithms process normally.
TX/RX LED Front panel communication light; flashes rapidly to indicate active digital backplane traffic.
CHALRM LEDs (1 - 16) Channel status lights; independent LEDs illuminate directly to show when a specific relay channel is tripped.
Rear Terminal Block Contacts I/O backplane connection pins grouping Common (COM), Normally Open (NO), and Normally Closed (NC) lines.
Relay Mode Toggles Physical multi-position dual-throw onboard switches assigning individual channel states to NDE or NE.

Installation Guidelines

  • Rack Positioning: Slide the complete 3500/33-03-00 149992-03 module assembly into any available full-height slot located strictly to the right of the Transient Data Interface (TDI) module.
  • Rear Alignment: Secure the corresponding 16-channel internal termination input/output module (such as 149986-01) into the matching rear slot directly behind the main card.
  • Onboard Switch Configuration: Adjust the internal physical toggle switches to determine the required Normally Energized or Normally De-energized status for each channel before sliding the board into the live slot.
  • Loop Voltage Verification: Confirm that the downstream instrumentation loops comply strictly with low-voltage and low-current constraints; introducing heavy inductive or high-power loads will destroy the gold-plated contact surfaces.
  • Logic Deployment: Open the system rack software suite to map and download the intended AND/OR safety voting matrix into the module non-volatile memory prior to system testing.

Compliance and Certifications

  • EMC Directives: European Community Directive 2014/30/EU (EMC Directive).
  • EMC Standards: EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).
  • Electrical Safety: Low Voltage Directive 2014/35/EU, EN 61010-1 Standard.
  • RoHS Directive: 2011/65/EU European Compliance.
  • Hazardous Area Approvals: cNRTLus Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc / Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC).
  • ATEX/IECEx Approvals: II 3 G Ex nA nC ic IIC T4 Gc / Ex ec nC ic IIC T4 Gc.

FAQ

What is the functional relationship between the 3500/33-03-00 code and the 149992-03 part number?

The 3500/33-03-00 represents the complete factory ordering model number specifying a 16-channel relay system configured for low-current applications, while the 149992-03 is the exact manufacturer part number printed on the physical low-current main processor board included in that specific combination.

Why is gold plating critical for the contacts on this module?

Gold plating is vital for low-current circuitry (down to 1 V, 1 mA) because standard silver contacts develop surface oxidation layers over time under low electrical loads, whereas gold resists tarnish to guarantee a clean connection path.

Can I perform a hot-swap on this module while machinery monitoring is actively running?

Yes, the unit features a fully hot-swappable architecture, allowing maintenance teams to remove or insert the card into the slot without disconnecting power or causing signal drops on adjacent monitor channels.

Does a single order of this product supply both the front processor and the rear terminal board?

When purchased as a complete surplus or spare assembly assembly under these factory specifications, it typically denotes the main card; ensure you verify whether your specific system panel requires the matching 149986-01 rear internal termination block as well.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Argent
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...