1 de 3

Moniteur de pression de cylindre à piston réciproque Bently Nevada 3500/77M-04-00 143737-01

Moniteur de pression de cylindre à piston réciproque Bently Nevada 3500/77M-04-00 143737-01

Il ne reste que 4 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 3500/77M-04-00 143737-01

  • Pays d'origine :États-Unis

  • Type de produit : Moniteur de pression du cylindre réciproque

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 1120g

  • Dimensions : 241,3 mm x 24,4 mm x 241,8 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

The 3500/77M, full part number 3500/77M-04-00 (incorporating main monitor module 3500/77M and rear I/O component 143737-01), is a 4-channel hardware module engineered within the 3500 Machinery Protection System to condition absolute pressure signals from approved positive voltage third-party transducers installed on reciprocating compressors. The instrument operates via continuous backplane communication to execute machinery protection logic by comparing eight discrete measured variables per channel—specifically Discharge Pressure, Suction Pressure, Maximum Pressure, Minimum Pressure, Compression Ratio, Peak Rod Compression, Peak Rod Tension, and Degree of Rod Reversal—against user-configurable alert and danger setpoints. This option -04-00 variant is structurally defined by a cylinder pressure I/O module with external termination interfaces and no hazardous area agency approvals required. The module delivers internal current-limiting transducer power supplies at +23.0 Vdc per channel and outputs inverted, offset buffered analog signals through front-panel coaxial ports for diagnostic cross-analysis without impacting primary monitoring operations.

Ordering Information

  • 3500/77M-04-00: Complete Cylinder Pressure Monitor Assembly
    • Specifies the combined kit consisting of the front main monitor module and the rear I/O module.
  • -04: I/O Module Type Option
    • Cylinder Pressure I/O Module with External Terminations (Rear I/O Module Part Number: 143737-01).
  • -00: Agency Approval Option
    • No hazardous area agency approvals or certifications required.
  • Spares & Accessories
    • Part Number 143737-01: Cylinder Pressure I/O Module with External Terminations for Bently Approved Third-Party Pressure Transducers.

Hardware Specifications

Parameter Specification
Manufacturer Bently Nevada
Model / Part Number 3500/77M-04-00 (I/O Board: 143737-01)
Channel Capacity 4 Configurable pressure channels
Input Signal Range +0.5 Vdc to +10.0 Vdc (assuming +0.5 Vdc at 0 psia)
Input Impedance 50 kΩ
Frequency Response 0 to 5.5 kHz on all configured channels
Pressure Accuracy at +25 °C Within ± 0.5% of pressure transducer full-scale (9.5 V range)
Pressure Accuracy (-30 °C to +65 °C) Within ± 1.0% of pressure transducer full-scale (9.5 V range)
Power Consumption 7.8 W maximum at full transducer load
Buffered Transducer Outputs Front panel coaxial ports, inverted and offset by -2.265 Vdc
Buffered Output Impedance 550 Ω
Transducer Power Supply +23.0 ± 0.8 Vdc with 24.5 mA current limiting per channel
Operating Temperature -30 °C to +65 °C
Storage Temperature -40 °C to +85 °C
Relative Humidity 95%, non-condensing
Combined Total Weight 1.11 kg (Combined monitor front card and rear I/O module)
Monitor Module Dimensions 241.3 mm x 24.4 mm x 241.8 mm
Monitor Module Weight 0.91 kg
I/O Module Dimensions 241.3 mm x 24.4 mm x 99.1 mm
I/O Module Weight 0.20 kg

Engineering Notes

  • The cylinder pressure I/O module processing logic dynamically alters its signal conversion scale factor based on the programmed target range, scaling from 95,000 mV/psi for 100 psia down to 950 mV/psi for 10,000 psia systems.
  • For single-chamber rod dynamics diagnostics, Peak Rod Compression, Peak Rod Tension, and Degree of Rod Reversal calculations mathematically integrate physical raw casing measurements with internal multi-channel variables.
  • Front panel buffered coaxial outputs are short-circuit protected but are structurally inverted and offset by -2.265 Vdc when interacting with the external termination I/O module architecture.
  • Control logic allows the mapping of independent alert setpoints across all active measured variables, whereas danger setpoints are strictly limited to a maximum of two variables per channel.

Field Guidelines

  • Connect the external termination block to the rear I/O chassis interface via shielded, twisted-pair wiring assemblies to preserve high-frequency signal integrity and prevent noise injection.
  • Terminate the field transducer cable shields exclusively at the designated external termination block ground strip to avoid creating parallel ground loops with the machine casing ground.
  • Observe the strict 24.5 mA current-limiting parameters on the +23.0 Vdc internal supply lines when interfacing with third-party absolute pressure sensors.
  • Maintain minimum bend radius limits for all external field cabling routing into the 3500 chassis enclosure to eliminate mechanical tension on the termination terminal blocks.

Technical & Procurement FAQ

Q: Why do the front-panel buffered outputs on the 3500/77M-04-00 show negative voltage offsets on an oscilloscope?

A: This behavior is normal for this specific architecture; the cylinder pressure external termination I/O electronics are structurally designed to invert and offset the raw signal by -2.265 Vdc.

Q: Can this pressure monitor module be swapped or inserted into any random slot within a 3500 rack?

A: No, the module must be positioned into a standard chassis slot compatible with monitoring modules and must line up directly with its corresponding 143737-01 rear external termination I/O board.

Q: What is the maximum distance or line resistance supported for the third-party pressure transducer connection?

A: Cable distance limits depend on the specific capacitance of the field cable, but signal integrity over long distances is maintained due to the high 50 kΩ input impedance of the I/O block.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Argent
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...