1 de 3

Transmetteur de poussée Bently Nevada 991-01-XX-01-00 MOD:284318-01

Transmetteur de poussée Bently Nevada 991-01-XX-01-00 MOD:284318-01

Il ne reste que 6 article(s) en stock
  • Fabricant : Bently Nevada

  • N° de produit : 991-01-XX-01-00 MOD:284318-01

  • Pays d'origine :États-Unis

  • Type de produit : Transmetteurs de vibration

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 430g

  • Dimensions : 10 cm x 7,3 cm x 6 cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The 991-01-XX-01-00 (Internal SKU/Part Number: 284318-01) is a rugged, loop-powered, two-wire 991 Thrust Transmitter engineered by Bently Nevada (a Baker Hughes business) to provide continuous machinery asset protection by interfacing field transducers directly with plant control networks. Unlike radial vibration models, this specialized transmitter is dedicated to measuring axial thrust position (the relative movement of a machine's rotor toward or away from the thrust bearing face). It integrates the high-frequency signal conditioning electronics of a proximity sensor and an analog transmitter into a single, compact housing. The unit accepts input signals from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable, processing raw target gap variations into a linear 4 to 20 mA analog current loop output proportional to total axial displacement.

This exact hardware configuration features a factory-calibrated full-scale measurement scale of 50-0-50 mils (1.2-0-1.2 mm), which represents a standard full displacement span of 100 mils (2.5 mm) centered around a zero-voltage mid-point bias. The physical casing comes integrated with 35 mm DIN rail clips for rapid, toolless snap-on mounting into field marshalling junctions or local boxes. The agency option is designated as -00, representing the standard general-purpose unclassified zone base model. The internal engineering part number 284318-01 designates the modern manufacturing build variant, featuring upgraded high-stability surface-mount components, optimized temperature compensation filters, and enhanced RFI/EMI shielding over legacy configurations.

Features

  • Two-wire, loop-powered architecture delivering a direct 4 to 20 mA analog current signal straight to host DCS or PLC processing cards.
  • Standardized 50-0-50 mils (1.2-0-1.2 mm) linear scale window explicitly tailored for dual-direction axial thrust safety tracking.
  • Integral 35 mm DIN rail mounting clips allowing rapid, secure snap-fit structural deployment on enclosure racks.
  • General-purpose unclassified zone footprint (-00 option) providing cost-effective, high-integrity signal loops.
  • Modern 284318-01 hardware design providing superior thermal stability and lower scale factor drift under fluctuating industrial temperatures.
  • Front-mounted, isolated BNC dynamic terminal providing raw, unconditioned voltage waveforms for local diagnostic data collectors.
  • Independent, non-interacting zero and span controls allowing seamless, single-point calibration trims under field conditions.

Applications

  • Continuous axial thrust position tracking and rotor displacement protection on critical industrial steam or gas turbines.
  • Direct safety loop integration on heavy-duty process gas compressors, turbo-expanders, and multi-stage boiler feed pumps.
  • Standalone machinery protection marshaling panels inside balance-of-plant utility areas and power generation modules.

Option String Breakdown

Option Code Slot Selected Option Value Technical Detail
Model Number 991 991 Thrust Transmitter Product Line
A: Full-scale Option -01 50-0-50 mils (1.2-0-1.2 mm) target displacement range
B: System Length Option -XX Configurable system loop length (Matches probe/cable parameters)
C: Mounting Option -01 35 mm DIN rail clips factory-installed
D: Agency Approval -00 None (Standard safety area classification for non-hazardous zones)
Internal Assembly SKU 284318-01 Modern factory production assembly code

Technical Specifications

Parameter Detail
Manufacturer Bently Nevada (Baker Hughes)
Ordering Suffix Code 991-01-XX-01-00
OEM Assembly Part ID 284318-01
Product Category Two-Wire Proximity Thrust Position Transmitter
Full Scale Linear Range 50-0-50 mils (1.2-0-1.2 mm) total axial displacement
Output Loop Signaling Proportional 4 to 20 mAdc current loop
Buffered Output Scale Factor Nominal 7.87 V/mm (200 mV/mil) corresponding to the raw probe gap voltage
Buffered Output Impedance 10 kohm nominal (Protected against continuous short circuit faults)
Supply Voltage Window +12 Vdc to +35 Vdc loop power required at the terminal links
Transducer System Match Calibrated for 3300 XL 8mm proximity probe and extension cable loops
Field Wiring Block Capacity Accepts wire gauges up to 1.5 mm squares (16 to 24 AWG) solid or stranded
Enclosure Construction Material Polycarbonate body structure integrated with an aluminum base plate
Net Component Weight 0.43 kg (0.9 lbm)
Operating Temperature Bounds -35 degC to +85 degC
Storage Temperature Bounds -51 degC to +100 degC
Relative Humidity Index 95% maximum, non-condensing atmosphere constraints

Connections/Interfaces

Terminal Connection Function Assignment
PROBE Coaxial Port Miniature coaxial connection point receiving the incoming transducer extension cable
+ (SIG) Terminal Positive current loop terminal receiving incoming +12 to +35 Vdc loop power inputs
- (COM) Terminal Negative current loop connection returning the regulated 4 to 20 mA measurement signal
BUF BNC Port Front-panel isolated BNC socket providing unconditioned sensor voltage waves

Installation Guidelines

  • DIN Rail Alignment: Position the transmitter housing directly over standard 35 mm DIN rail tracking. Apply firm downward pressure until the integrated plastic clips snap tightly over the rail flanges.
  • Chassis Frame Isolation: Ensure the internal ground planes remain isolated from bare electrical conduit paths. The transmitter backplate must remain isolated from structural rack frames to eliminate low-voltage ground loops.
  • System Length Synchronization: Check that your specified system length option (Option -XX) perfectly matches the total physical length of the attached 3300 XL 8mm probe and extension cable to maintain calibrated accuracy.
  • Mechanical Gap Offsetting: During probe installation, the target face should be mechanically positioned so the probe sits at the physical center of its linear range (typically corresponding to a 12 mA output loop current and a specific DC voltage bias on the BNC port) when the rotor is at its normal active thrust position.
Loading product navigation…

Que représentent un signal de courant de boucle de 4 mA, 12 mA et 20 mA sur ce transmetteur de poussée 991 ?

Puisque ce transmetteur est calibré pour une plage de poussée de 50-0-50 mils, le point médian de la plage est représenté par 12 mA (position zéro centrée normale). Un courant de 4 mA représente un déplacement complet en direction de la contre-poussée (-50 mils), tandis que 20 mA représente un déplacement complet en direction de la poussée (+50 mils).

Comment le module électronique 284318-01 réagit-il si la pointe de la sonde de proximité de terrain s’use ou entre en contact avec l’arbre ?

Si la pointe de la sonde entre en contact physique avec la cible de l’arbre, l’écart du capteur tombe à zéro, forçant le pilote du transducteur en saturation. La logique de diagnostic interne du transmetteur 284318-01 enregistre cela comme une faute hors limites et bride la sortie de courant 4-20 mA à un état d’erreur bas (< 3,6 mA), garantissant que le DCS signale une erreur de capteur au lieu de déclencher un arrêt machine erroné basé sur de mauvaises données.

Pourquoi est-il crucial d’éviter le contact à la terre sur les connecteurs du câble coaxial miniature d’extension pour le circuit du transmetteur 991 ?

Le corps du connecteur coaxial transporte le signal porteur radiofréquence (RF) basse tension haute fréquence issu de la boucle d’oscillateur interne du transmetteur. Si le châssis métallique nu du connecteur touche une boîte de jonction mise à la terre ou un conduit structurel, il met à la terre la boucle RF, désactivant le canal de mesure et forçant la sortie de courant dans un état de défaut. Les techniciens doivent protéger cette jonction avec des manchons isolants pour connecteurs ou du ruban silicone auto-fusionnant.

Le port BNC en façade peut-il être surveillé en continu pendant le fonctionnement de la machine pour une analyse spectrale ?

Oui. Le port BNC avant fournit une sortie analogique tamponnée non conditionnée de la forme d’onde de tension brute de la sonde (calibrée à 200 mV/mil). Ce port est entièrement isolé de la boucle de mesure principale 4-20 mA. Connecter un collecteur de données de vibration permanent, un analyseur portable ou un oscilloscope au terminal BNC ne surcharge pas, ne modifie pas et n’interrompt pas la boucle de signalisation principale envoyée au PLC/DCS hôte.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre
Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...