The Honeywell 05701-A-0301 is a microprocessor-based Single Channel Control Card within the System 57 engineering framework, developed to process, display, and manage field-mounted gas detection sensors. This control module interfaces seamlessly with 4 - 20mA gas transmitters or loop-powered gas sensors via an integrated plug-in sensor drive module. Operating as an independent element in high-integrity safety systems, the card performs constant validation of internal circuitry, active software operation, and physical sensor health.

The module translates complex electrochemical, toxic, or combustible field signals directly onto a dedicated four-part liquid crystal display on the front face, combining an analogue bar segment indicator with digital messaging readouts for localized engineering tracking. It evaluates live field inputs against programmable parameters to drive active alarm thresholds, coordinating safety loops across the backplane to drive relay behaviors and optional isolated multi-drop current monitors.

Features

  • Built with a dedicated four-part liquid crystal display comprising a 25-segment analogue bar graph, a 4-character digital value window, a 4-character message line, and explicit operational icons.
  • Equipped with low-latency front-panel status LEDs for A1, A2, A3 gas alarms, dedicated system Fault, and channel Inhibit indicators.
  • Features an integrated, multi-functional front Reset/Select push-button to allow localized alarm clearing and card matching alongside a system Engineering Card.
  • Provides high-granularity configuration with Alarm Setting Point Resolution fully adjustable in fine 1% fsd (full scale deflection) steps.
  • Sustains precision safety monitoring using an electronic architecture boasting an exceptionally stable Electronic Drift pattern restricted to less than plus or minus 2% over a 6-month operational window.

Applications

  • Multi-zone monitoring of toxic and flammable gases within industrial chemical processing plants, refineries, and offshore infrastructure platforms.
  • Marshaling panel integration for processing inputs from loop-powered gas transmitters running into central instrumentation rooms.
  • Specialized marine, utility, and heavy fabrication facilities requiring high-integrity independent gas detection channels.

Technical Specifications

Parameter Specifications
Manufacturer Honeywell
Model Number 05701-A-0301
Product Type Single Channel Control Card 4 - 20mA
Product Series System 57 / 5701 Series Control System
Microprocessor Configuration Storage Onboard EEPROM
DC Supply Voltage Range 18V to 32V dc
Power Consumption (4 - 20mA) 3.25W (typical)
Power Consumption (Catalytic Option) 3.75W (typical)
Electronic Drift Rate Less than ±2% / 6 months
Maximum Output Source Current 500mA maximum from individual card field terminals
Alarm Point Adjustability 1% fsd steps
Country of Origin United Kingdom
Dimensions (L x W x H) 17cm x 2.5cm x 11.2cm
Weight 0.165 Kg

Connections/Interfaces

Connector / Terminal Function
SK1 15-way D-type female socket providing physical coupling to the field interface or relay card
SK2 32-way backplane interface socket routing power paths and shared serial bus communications
J1 / J2 14-way onboard plug-in headers accommodating factory-fitted sensor drive modules
J3 / J4 8-way expansion connectors allowing modular plug-in of the isolated Analogue Output Module
FS1 Internal protection circuit fuse

Installation Guidelines

  • Sub-Rack Chamber Isolation: Install the module inside the designated, sealed electromagnetic interference (EMI) chamber of the 19-inch or half 19-inch System 57 sub-rack to safeguard precision logic components.
  • Field Cabling Parameters: Attach all field connections via the dedicated mating Interface or Relay Card terminals, using multi-stranded shielded cables up to 2.5mm2 to secure input paths.
  • Shield Grounding Methods: Terminate the external cable outer shield explicitly at the single Ground terminal block on the Interface/Relay Card or through standard metallic cable glands to isolate noise loop entry.
  • Single-End Shield Policy: If field sensors are grounded locally through their structural enclosures or mounting plates, maintain the shielding continuity by connecting the screen sheath only at one termination point (either field end or rack end) to avert dangerous ground loops.
  • Maximum Source Limits: Ensure that any connected loop-powered transmitter or auxiliary field instrument does not pull a continuous load exceeding 500mA from the individual display card pins.

FAQ

  • How is the specific gas scaling and range profile configured on this module?

    Operational setups and range specifications are managed digitally via a microprocessor system and securely written to an onboard non-volatile EEPROM, which can be modified through an Engineering Card or linked interface PC running diagnostic software.

  • Can this single channel card accept direct catalytic sensor bridge inputs?

    The 05701-A-0301 card is factory-equipped with a 4 - 20mA input conditioning module. For direct three-wire catalytic gas sensor installations, the sister card model 05701-A-0302 must be selected instead.

  • What happens if a loop device requires more than the 500mA sourcing current limit?

    If a field transmitter demands an operational or start-up current value exceeding 500mA, it must be powered using an independent external 24V DC auxiliary field power supply loop rather than drawing directly from the card.

  • Is it safe to pull the card out of the rack assembly while neighboring loops are running?

    Yes, each channel loop behaves as an independent circuit node, meaning separate control card cards can be unplugged or serviced inside a standard sub-rack arrangement without disrupting adjacent process security loops.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...